Content preview

North Carolina Fire Inspector Level I Certification
Examination Complete Questions And Detailed
Solutions Latest Update This Year

Q1: North Carolina Fire Inspector Level I - which codes adopted?
A. Only electrical code
B. 2021 NC Fire Code which is 2021 International Fire Code IFC with NC amendments, 2018 NC Building Code based on 2015 IBC
with NC amendments, 2018 NC Existing Building Code, NFPA 13, NFPA 72, NFPA 25 per NC State Building Code Council and NC
Office of State Fire Marshal OSFM
C. No codes in NC
D. Only 1990 Fire Code
Answer & ULTRA-Detailed Rationale:

B. 2021 NC Fire Code which is 2021 International Fire Code IFC with NC amendments, 2018 NC Building Code based on 2015 IBC with
NC amendments, 2018 NC Existing Building Code, NFPA 13, NFPA 72, NFPA 25 per NC State Building Code Council and NC Office of
State Fire Marshal OSFM

CONCEPT: NC codes adopted. CORRECT - A: North Carolina Fire Inspector Level I per NC Office of State Fire Marshal OSFM and NC
State Building Code Council - Codes adopted: 2021 North Carolina Fire Code which is 2021 International Fire Code IFC with NC
amendments effective 2022, 2018 North Carolina Building Code which is 2015 International Building Code IBC with NC amendments,
2018 NC Existing Building Code, referenced NFPA standards: NFPA 13 Installation of Sprinkler Systems, NFPA 72 National Fire Alarm
Code, NFPA 25 Inspection Testing Maintenance of Water-Based Fire Protection Systems, NFPA 10 Portable Fire Extinguishers, NC
General Statute 58 Article 11. WHY B WRONG: Only 1990 Fire Code false - NC currently uses 2021 NC Fire Code - 1990 outdated -
inspector must use current adopted. WHY C WRONG: Only electrical false - fire inspector uses NC Fire Code IFC, NC Building Code
IBC, NFPA standards - not only electrical NEC. WHY D WRONG: No codes false - NC has adopted codes - NC Fire Code, NC Building
Code, NFPA referenced. EXAM TIP: NC 2021 NC Fire Code is 2021 IFC with NC amendments, 2018 NC Building Code is 2015 IBC
with amendments - NFPA 13 sprinkler, NFPA 72 alarm, NFPA 25 ITM.




Page 1 | NC FIRE INSPECTOR LEVEL I - ULTRA - BIG TITLE - 200Q

,Q2: Fire Inspector Level I duties per NC OSFM and NFPA 1031?
A. No duties
B. Fire Inspector Level I per NFPA 1031 Standard for Professional Qualifications for Fire Inspector - duties: conduct fire inspections of
existing occupancies, identify fire hazards, ensure compliance with fire code, review and observe - cannot perform plans review for
new construction which is Level II - per NC OSFM qualification board
C. Can do plans review for high-rise new construction as Level I
D. Only arson investigation
Answer & ULTRA-Detailed Rationale:

B. Fire Inspector Level I per NFPA 1031 Standard for Professional Qualifications for Fire Inspector - duties: conduct fire inspections of
existing occupancies, identify fire hazards, ensure compliance with fire code, review and observe - cannot perform plans review for new
construction which is Level II - per NC OSFM qualification board

CONCEPT: Level I duties per NFPA 1031. CORRECT - A: Fire Inspector Level I per NFPA 1031 and NC OSFM NC Fire Inspector
Certification: duties: conduct basic fire inspections of existing occupancies - e.g., business mercantile assembly storage - identify fire
hazards violations, ensure compliance with NC Fire Code, issue notices, conduct follow-up inspections, observe fire drills - Cannot
perform technical plans review for new construction high-rise complex which is Level II and Level III - per NC OSFM NC Administrative
Code 11C - Level I limited to existing occupancies inspection. WHY B WRONG: Can do plans review for high-rise new construction as
Level I false - Level I cannot do plans review for new construction - Level II does plans review - Level I limited existing inspections -
high-rise complex Level II/III. WHY C WRONG: No duties false - Level I has duties fire inspections existing occupancies hazard
identification compliance. WHY D WRONG: Only arson investigation false - arson investigation is Fire Investigator per NFPA 1033 - not
Fire Inspector Level I - Level I inspections. EXAM TIP: Level I per NFPA 1031 = existing occupancies inspection only - cannot plans
review new construction - that is Level II - Fire Investigator is NFPA 1033 separate.



Q3: Means of egress per NC Fire Code Chapter 10 and NC Building Code Chapter 10 - inspector checks?
A. Travel distance unlimited
B. Means of egress per IFC/NCFC Chapter 10: 3 parts - exit access, exit, exit discharge - occupant load per Table 1004.5, egress
width per 1005, travel distance per 1017, common path per 1006.2.1, number of exits per 1006, door hardware per 1010.1.4.1 panic
hardware if 50+ occupant load assembly, emergency lighting per 1008.3, exit signs per 1013
C. No egress needed
D. Only one exit always OK
Answer & ULTRA-Detailed Rationale:

B. Means of egress per IFC/NCFC Chapter 10: 3 parts - exit access, exit, exit discharge - occupant load per Table 1004.5, egress width
per 1005, travel distance per 1017, common path per 1006.2.1, number of exits per 1006, door hardware per 1010.1.4.1 panic hardware
if 50+ occupant load assembly, emergency lighting per 1008.3, exit signs per 1013

CONCEPT: Means of egress. CORRECT - A: Means of egress per NC Fire Code Chapter 10 and NC Building Code Chapter 10 per IFC
Chapter 10: 3 parts: exit access path to exit, exit protected enclosure, exit discharge to public way - Inspector checks: occupant load per
Table 1004.5 e.g., business 100 sq ft per person mercantile 60, egress width per 1005.3.1 0.3 inch per occupant for stairs 0.2 inch for
level, travel distance per Table 1017.2 e.g., business unsprinklered 200 ft sprinklered 300 ft, common path of travel per 1006.2.1,
number of exits per 1006 minimum 2 if occupant load greater than 49 or travel greater than 75 ft, door hardware per 1010.1.4.1 panic
hardware required if assembly or educational 50+ occupant load, emergency lighting per 1008.3, exit signs per 1013 illuminated. WHY B
WRONG: No egress needed false - means of egress required per NCFC Chapter 10 - life safety - must provide. WHY C WRONG: Only
one exit always OK false - number of exits per 1006 - if occupant load greater than 49 or common path greater than 75 ft need 2 exits -
one exit only allowed small occupant load per 1006.2.1 e.g., business 49 occupant load 75 ft common path. WHY D WRONG: Travel
distance unlimited false - travel distance limited per Table 1017.2 - e.g., business unsprinklered 200 ft sprinklered 300 ft - assembly
unsprinklered 200 ft sprinklered 250 ft. EXAM TIP: Egress 3 parts: exit access, exit, exit discharge - occupant load Table 1004.5
business 100 gross mercantile 60 gross assembly standing 5 - travel distance Table 1017.2 business 200 unsprinklered 300 sprinklered
- 2 exits if greater than 49 occupant load or common path greater than 75 ft - panic hardware if assembly/educational 50+ per
1010.1.4.1.




Page 2 | NC FIRE INSPECTOR LEVEL I - ULTRA - BIG TITLE - 200Q

,Q4: Fire protection systems - sprinkler NFPA 13 and alarm NFPA 72 - inspector Level I checks per NC?
A. No fire protection needed
B. Sprinkler only in high-rise
C. No alarm needed
D. NC Fire Code Chapter 9 Fire Protection Systems: automatic sprinkler required per Table 903.2 based on occupancy and area,
inspection testing maintenance per NFPA 25, fire alarm required per Table 907.2, ITM per NFPA 72, portable fire extinguishers per
NFPA 10 and NCFC 906 - inspector checks presence coverage per NFPA 13
Answer & ULTRA-Detailed Rationale:

D. NC Fire Code Chapter 9 Fire Protection Systems: automatic sprinkler required per Table 903.2 based on occupancy and area,
inspection testing maintenance per NFPA 25, fire alarm required per Table 907.2, ITM per NFPA 72, portable fire extinguishers per
NFPA 10 and NCFC 906 - inspector checks presence coverage per NFPA 13

CONCEPT: Fire protection systems. CORRECT - A: Fire Protection Systems per NC Fire Code Chapter 9 per IFC Chapter 9: automatic
sprinkler system required per Section 903.2 based on occupancy fire area - e.g., assembly 12,000 sq ft or 300+ occupant load, business
12,000 sq ft, educational, factory per Table 903.2 - must be installed per NFPA 13 Standard Installation Sprinkler Systems - inspection
testing maintenance ITM per NFPA 25, fire alarm system required per Table 907.2 based on occupancy - e.g., assembly 300+ occupant
load, educational, business 500+ - installed per NFPA 72 National Fire Alarm Code - ITM per NFPA 72, portable fire extinguishers per
NFPA 10 and NCFC Section 906 - travel 75 ft max for ordinary hazard - Level I inspector checks presence coverage but not detailed
design which is Level II. WHY B WRONG: No fire protection needed false - Chapter 9 requires sprinkler alarm extinguishers based on
occupancy area. WHY C WRONG: Sprinkler only high-rise false - sprinkler required many occupancies not only high-rise - per Table
903.2 assembly business educational factory storage. WHY D WRONG: No alarm needed false - fire alarm required per Table 907.2 -
e.g., assembly 300+ occupant load educational business. EXAM TIP: Sprinkler required per Table 903.2 assembly 12k sq ft or 300+
occupant business 12k, alarm per Table 907.2 assembly 300+ occupant - NFPA 13 sprinkler NFPA 72 alarm NFPA 25 ITM sprinkler
NFPA 10 extinguishers 75 ft travel.



Q5: Hazardous materials per NC Fire Code Chapter 50 - inspector checks?
A. No SDS needed
B. No hazardous materials regulated
C. Unlimited quantities allowed without permit
D. Hazardous materials per NCFC Chapter 50 and IFC Chapter 50: classification physical and health hazards, maximum allowable
quantities MAQ per Table 5004.1, permits required per NCFC 5001.5, storage cabinets per NFPA 30, MSDS SDS now, placards per
NFPA 704, inspection checks quantities storage handling
Answer & ULTRA-Detailed Rationale:

D. Hazardous materials per NCFC Chapter 50 and IFC Chapter 50: classification physical and health hazards, maximum allowable
quantities MAQ per Table 5004.1, permits required per NCFC 5001.5, storage cabinets per NFPA 30, MSDS SDS now, placards per
NFPA 704, inspection checks quantities storage handling

CONCEPT: Hazardous materials. CORRECT - A: Hazardous Materials per NC Fire Code Chapter 50 per IFC Chapter 50: classification
physical hazards flammable combustible explosive and health hazards toxic corrosive - maximum allowable quantities MAQ per Table
5004.1 per control area - e.g., flammable liquid Class IB 120 gallons closed 60 open - permits required per NCFC 5001.5 if exceed MAQ,
storage in approved cabinets per NFPA 30 Flammable Liquids Code, safety data sheets SDS per OSHA 1910.1200 HazCom - formerly
MSDS, placards labeling per NFPA 704 diamond, inspection checks quantities storage handling ventilation - Level I identifies need for
Level II. WHY B WRONG: No hazardous materials regulated false - Chapter 50 regulates hazardous materials - MAQ permits storage.
WHY C WRONG: Unlimited quantities without permit false - quantities limited per Table 5004.1 MAQ - exceed requires permit and
additional protection. WHY D WRONG: No SDS needed false - SDS required per OSHA 1910.1200 HazCom - must have SDS for
hazardous materials. EXAM TIP: Hazmat Chapter 50 MAQ per Table 5004.1 e.g., flammable Class IB 120 gal closed 60 open per
control area - permit if exceed per 5001.5 - NFPA 30 cabinets NFPA 704 placard SDS per OSHA HazCom.




Page 3 | NC FIRE INSPECTOR LEVEL I - ULTRA - BIG TITLE - 200Q

, Q6: Fire Inspector certification in NC - how to become Level I per OSFM?
A. NC OSFM NC Fire and Rescue Commission - requires: Fire Inspector Level I course per NC OSFM, pass state exam,
prerequisites may include Firefighter or code knowledge, continuing education 36 hours every 3 years per NC Administrative Code
11C .0800, must be affiliated with fire department or inspection agency
B. No certification needed in NC
C. No CE needed
D. Only high school diploma needed no course
Answer & ULTRA-Detailed Rationale:

A. NC OSFM NC Fire and Rescue Commission - requires: Fire Inspector Level I course per NC OSFM, pass state exam, prerequisites
may include Firefighter or code knowledge, continuing education 36 hours every 3 years per NC Administrative Code 11C .0800, must
be affiliated with fire department or inspection agency

CONCEPT: NC certification process. CORRECT - A: NC Fire Inspector Level I certification per NC Office of State Fire Marshal OSFM
and NC Fire and Rescue Commission per NC Administrative Code Title 11 Chapter C .0800: requirements: complete NC OSFM
approved Fire Inspector Level I course - e.g., 40-80 hours, pass NC state exam per NFPA 1031 Level I objectives, prerequisites may
include basic firefighting or code enforcement background, continuing education CE 36 hours every 3 years per 11C .0805 to maintain
certification, must be affiliated with fire department fire prevention bureau or inspection agency per NC GS 58 - Level II requires Level I
plus additional course. WHY B WRONG: No certification needed false - NC requires certification per OSFM per NC Administrative Code
11C - must be certified to conduct inspections. WHY C WRONG: Only high school diploma no course false - requires Level I course and
state exam - not only diploma - course required. WHY D WRONG: No CE needed false - CE required 36 hours every 3 years per 11C
.0805 to maintain - must have CE. EXAM TIP: NC OSFM Fire Inspector Level I course + state exam per NFPA 1031 - CE 36 hours every
3 years per 11C .0805 - affiliated with fire department - Level II requires Level I + additional course + plans review.



Q7: Fire extinguishers and commercial cooking per NCFC?
A. Commercial cooking no hood needed
B. No extinguishers needed
C. Extinguisher travel unlimited
D. Portable fire extinguishers per NCFC 906 and NFPA 10: required per Table 906.3(1), travel distance 75 ft for ordinary hazard, 30 ft
for extra hazard, inspection monthly visual annual maintenance, commercial cooking per NCFC 904 and NFPA 96 - Type I hood
grease, fire suppression automatic per 904.11, cleaning per NFPA 96
Answer & ULTRA-Detailed Rationale:

D. Portable fire extinguishers per NCFC 906 and NFPA 10: required per Table 906.3(1), travel distance 75 ft for ordinary hazard, 30 ft for
extra hazard, inspection monthly visual annual maintenance, commercial cooking per NCFC 904 and NFPA 96 - Type I hood grease, fire
suppression automatic per 904.11, cleaning per NFPA 96

CONCEPT: Extinguishers and commercial cooking. CORRECT - A: Portable Fire Extinguishers per NC Fire Code 906 and NFPA 10
Standard Portable Fire Extinguishers: required per Table 906.3(1) based on occupancy hazard - travel distance 75 ft max for ordinary
hazard per NFPA 10 6.2.1.3.1, 30 ft for extra hazard cooking, inspection monthly visual check per NFPA 10 7.2.2, annual maintenance
per 7.2.2, 6 year internal 12 year hydrotest - Commercial Cooking per NCFC 904 and NFPA 96 Standard Ventilation Control Fire
Protection Commercial Cooking: Type I hood for grease smoke required, automatic fire suppression per 904.11 e.g., wet chemical Ansul,
cleaning per NFPA 96 11.6 - Level I inspector checks extinguishers present and cooking suppression. WHY B WRONG: No
extinguishers needed false - extinguishers required per Table 906.3(1) - most occupancies require - per NCFC 906. WHY C WRONG:
Commercial cooking no hood needed false - Type I hood required for grease per NCFC 904 and NFPA 96 - plus automatic suppression
per 904.11. WHY D WRONG: Extinguisher travel unlimited false - travel limited per NFPA 10 - 75 ft ordinary hazard 30 ft extra hazard -
unlimited would be too far. EXAM TIP: Extinguisher travel 75 ft ordinary 30 ft extra per NFPA 10 - monthly visual annual maintenance 6
year internal 12 year hydrotest - commercial cooking Type I hood grease + automatic suppression per NCFC 904.11 NFPA 96.




Page 4 | NC FIRE INSPECTOR LEVEL I - ULTRA - BIG TITLE - 200Q

Document information

Uploaded on
October 4, 2026
Number of pages
106
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$25.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
9
Followers
0
Items
1696
Last sold
2 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions