• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 2 out of 12 pages
Exam (elaborations)

Mako Comprehensive Resource To Help You Ace Exams Includes Frequently Tested Questions With ELABORATED 100% Correct COMPLETE SOLUTIONS Guaranteed Pass First Attempt!! Current Update!!

Document preview thumbnail
Preview 2 out of 12 pages

Mako Comprehensive Resource To Help You Ace Exams Includes Frequently Tested Questions With ELABORATED 100% Correct COMPLETE SOLUTIONS Guaranteed Pass First Attempt!! Current Update!! 1. During trialing, extension is stable, but flexion is tight. What is a potential solution? a. Translate femoral component superior/proximal b. Add extension to the femoral component c. Anterior reference and upsize the femoral component d. Anchor anterior and increase the posterior tibial slope - CORRECT ANSWER d. Anchor anterior and increase the posterior tibial slope 2. During trialing, after all bone cuts have been executed, internally or externally rotating the femoral component will trigger an 'Implant proud of cut' warning. a. True b. False - CORRECT ANSWER a. True 3. The Mako Total Knee preoperative planning guidelines are different from the Mako Total Knee goalpost intraoperative planning recommendations. a. True b. False - CORRECT ANSWER a. True 4. When sizing the Triatholon femoral component, which of the following is not recommended? a. Minimal bony coverage b. Maximum bony coverage c. Avoidance of encroachment on the intercondylar notch d. Avoidance of anterior notching - CORRECT ANSWER a. Minimal bony coverage 5. When posterior referencing is enabled for the femur, the anterior flange will remain fixed in place as the femoral component. a. True b. False - CORRECT ANSWER b. False 6. The CT slicer view in the planning page is used to: a. Verify the accuracy of performed bone resections b. Confirm accuracy of bone registration c. Achieve desired implant fit and assess overhang and bone coverage d. Verify the accuracy of CT landmarks - CORRECT ANSWER c. Achieve desired implant fit and assess overhang and bone coverage 7. During preoperative implant planning, femoral component concentricity is best assessed in the coronal plant. a. True b. False - CORRECT ANSWER b. False 8. Flexing the femoral component minimizes the risk of: a. Tight flexion gaps b. Femoral rollback c. Notching d. Tibia plateau fracture - CORRECT ANSWER c. Notching 9. If the user notices a flange tip warning, they should ________. a. Increase the flexion of the femoral component b. Increase the distal femoral resection c. Decrease the distal femoral resection d. Decrease the flexion of the femoral component - CORRECT ANSWER d. Decrease the flexion of the femoral component 10. What is the minimum UPS charge level for the Mako System to be powered on? a. 90% b. 80% c. 70% d. 85% - CORRECT ANSWER d. 85%

Content preview

Mako
Comprehensive Resource To Help You Ace Exams
Includes Frequently Tested Questions With
ELABORATED 100% Correct COMPLETE SOLUTIONS
Guaranteed Pass First Attempt!! Current Update!!


1. During trialing, extension is stable, but flexion is tight. What is a
potential solution?
a. Translate femoral component superior/proximal
b. Add extension to the femoral component
c. Anterior reference and upsize the femoral component
d. Anchor anterior and increase the posterior tibial slope -
CORRECT ANSWER d. Anchor anterior and increase the
posterior tibial slope

2. During trialing, after all bone cuts have been executed, internally or
externally rotating the femoral component will trigger an 'Implant
proud of cut' warning.
a. True
b. False - CORRECT ANSWER a. True

3. The Mako Total Knee preoperative planning guidelines are different
from the Mako Total Knee goalpost intraoperative planning
recommendations.
a. True
b. False - CORRECT ANSWER a. True

4. When sizing the Triatholon femoral component, which of the following
is not recommended?
a. Minimal bony coverage
b. Maximum bony coverage
c. Avoidance of encroachment on the intercondylar notch
d. Avoidance of anterior notching - CORRECT ANSWER a.
Minimal bony coverage

, 5. When posterior referencing is enabled for the femur, the anterior
flange will remain fixed in place as the femoral component.
a. True
b. False - CORRECT ANSWER b. False

6. The CT slicer view in the planning page is used to:
a. Verify the accuracy of performed bone resections
b. Confirm accuracy of bone registration
c. Achieve desired implant fit and assess overhang and bone
coverage
d. Verify the accuracy of CT landmarks - CORRECT ANSWER c.
Achieve desired implant fit and assess overhang and bone
coverage

7. During preoperative implant planning, femoral component
concentricity is best assessed in the coronal plant.
a. True
b. False - CORRECT ANSWER b. False

8. Flexing the femoral component minimizes the risk of:
a. Tight flexion gaps
b. Femoral rollback
c. Notching
d. Tibia plateau fracture - CORRECT ANSWER c. Notching

9. If the user notices a flange tip warning, they should ________.
a. Increase the flexion of the femoral component
b. Increase the distal femoral resection
c. Decrease the distal femoral resection
d. Decrease the flexion of the femoral component - CORRECT
ANSWER d. Decrease the flexion of the femoral component

10. What is the minimum UPS charge level for the Mako System to
be powered on?
a. 90%
b. 80%
c. 70%
d. 85% - CORRECT ANSWER d. 85%

Document information

Uploaded on
October 3, 2026
Number of pages
12
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$11.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
EWLindy
3.8
(116)
Sold
780
Followers
432
Items
8857
Last sold
12 hours ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions