Exam 200 Questions and Correct Answers (Verified Answers)
Plus Rationales 2026 Q&A | Instant Download PDF Already
Graded A+
Question 1
Under the Safety Standards Act of BC, what is the primary legal
responsibility of an Electrical Field Safety Representative (FSR)?
A) To perform all electrical installations on behalf of contractors
B) To submit declarations confirming regulated electrical work complies
with code
C) To issue electrical permits to all contractors in their region
D) To conduct criminal background checks on electrical workers
Correct Answer: B
Explanation: An FSR's primary responsibility is to submit declarations
that confirm regulated electrical work complies with the Safety
Standards Act and applicable regulations. This is a legal statement
certifying that the work described in an electrical installation or
operating permit meets all safety requirements .
Question 2
A Class A FSR certificate allows declarations for electrical work with:
A) Maximum 600V voltage limitation
,B) Maximum 500 ampere limitation
C) No voltage or ampere limitations
D) Maximum 1000V and 1000 ampere limitation
Correct Answer: C
Explanation: Class A is the highest FSR designation and allows
submission of declarations for any type of regulated electrical work with
NO voltage or ampere limitations. This is the most comprehensive
certification level available .
Question 3
According to the Electrical Safety Regulation, what must an FSR verify
before submitting a declaration for a high voltage installation?
A) The contractor's business license status
B) That the installation complies with CE Code and applicable
regulations
C) The personal financial status of the electrical contractor
D) That all workers have completed red seal training
Correct Answer: B
Explanation: The Electrical Safety Regulation requires FSRs to verify that
electrical installations comply with the Canadian Electrical Code and
applicable regulations before submitting declarations. This ensures all
regulated work meets safety standards .
,Question 4
When must an FSR report an electrical incident to Technical Safety BC?
A) Only if property damage exceeds $10,000
B) When an incident results in injury, death, or significant safety hazard
C) Only when requested by the contractor
D) Within 72 hours regardless of severity
Correct Answer: B
Explanation: Incidents resulting in injury, death, or significant safety
hazards must be reported immediately, and in any case within 24 hours
of occurrence. This ensures Technical Safety BC can investigate and
prevent further incidents .
Question 5
What is the minimum passing grade required for the Class A FSR
examination?
A) 60%
B) 65%
C) 70%
D) 75%
Correct Answer: C
Explanation: Candidates must achieve a minimum grade of 70% to pass
the Class A FSR exam. This requirement ensures sufficient knowledge for
certification .
, Question 6
How many multiple-choice questions are on the Class A FSR exam?
A) 40
B) 50
C) 60
D) 80
Correct Answer: C
Explanation: The Class A FSR exam consists of 60 multiple-choice
questions. Candidates have 3.5 hours to complete the open-book
examination .
Question 7
What is the time limit between failing an FSR exam and rebooking for a
re-write attempt?
A) 10 days
B) 20 days
C) 30 days
D) 60 days
Correct Answer: C