Comprehensive Resource To Help You Ace Exams Includes
Frequently Tested Questions With ELABORATED 100%
Correct COMPLETE SOLUTIONS
Guaranteed Pass First Attempt!! Current Update!!
1. If you see an x-Ray tech or C-ARM in a room, you... - CORRECT
ANSWER must have lead apron on
2. Positive Pressure - CORRECT ANSWER more pressure inside the
room than outside the room (clean air rushes out instead of dirty
rushing in)
3. Negative Pressure - CORRECT ANSWER decontamination
-dirty air stays in the room, clean air rushes in (opposite of positive
pressure)
4. Terminology for OR tables/stands - CORRECT ANSWER -ring stand
-back table
-mayo stand: bring right up to operating table to pass instruments to
and from surgeon
5. Neptune vs. Suction Tree - CORRECT ANSWER both suck up
irrigation
-Neptune: cleans itself out (used for all cases, but a lot more to suck
up in ortho cases)
-Suction Tree: someone has to dump liquid into hopper or pour
powder in it to solidify
6. Channel 1 Connection on Tower - CORRECT ANSWER CCU
(Source) out --> SDC (Device) in --> SDC out --> Monitor (Display)
-wireless connection either from CCU (no flip-screen on additional
monitor) or from SDC (flip screen on additional monitor)
7. Remote Cables - CORRECT ANSWER 1. Pictures (1 --> 1)
, . Videos (2 --> 2)
8. Coupler - CORRECT ANSWER couples scope to camera head
9. Flip-Screen on Wireless Monitor - CORRECT ANSWER CCU -->
SDC
SDC --> Wireless
Wireless --> Monitor
*if you want to use this set-up, can plug 1 S-video into the CCU to
have ready to plug into additional monitor to cover all bases
10. No Flip-Screen on Wireless Monitor - CORRECT ANSWER
CCU --> SDC
CCU --> Wireless
SDC --> Monitor
11. Printer cable - CORRECT ANSWER connects from the printer
to the SDC
12. Up and Down Buttons on Camera Head - CORRECT ANSWER
increase and decrease GAIN
-amount of light allowed through camera head --> ex. opening and
closing a curtain
*if light is too bright from the light source, there will be a hot spot/glare
13. Light - CORRECT ANSWER -starts with X = Xenon bulb (lasts
for 500 hours)
-L9000 = LED (no light bulb, very bright)
14. SDC - CORRECT ANSWER -archive: loads info from previous
cases
-current case picks right up where you left off
15. Annotation - CORRECT ANSWER turn auto print off
-other than using annotation, always keep auto print on
16. Auto cut off/auto start - CORRECT ANSWER -auto cut off: if
they want case recorded in increments (default none)
, -default start: on to start next increment (default off)
17. Remote 2 control - CORRECT ANSWER pause or stop
-stop = stop and restart (easier because it's easier to edit)
18. Live video timeout - CORRECT ANSWER show picture so they
can decide if they want it
-default = 3 seconds
image format = BMP
19. Channel 1 and Channel 2 Connection on Tower - CORRECT
ANSWER -channel 1 same as above
-channel 2
Additional Source out --> SDC in --> SDC out --> monitor input
20. brightness and contrast - CORRECT ANSWER need to be
changed together
21. Scale Mode - CORRECT ANSWER -usually "filled to aspect"
for arthroscopy
-lap = fill all
*unique to facility
SDC3
Switchpoint/SI
22. PTZ - CORRECT ANSWER -SDC3: rolling color bars =
screensaver
-Switchpoint controls router
^can preset surgeon/group preferences
-PTZ: pan/tilt/zoom
"real time" - CORRECT ANSWER really long recording
-will prompt you to enter DVD