TRADESMAN EXAM COMPLETE STUDY GUIDE
WITH SOLVED QUESTIONS
◉ stand pipe receptor for clothes washer will stand above the trap
no less than.
Answer: 18 in
◉ building sewers will be tested by filling.
Answer: from the lowest point to 10ft high
◉ a plumbing vent will terminate no less than how many feet from a
air intake.
Answer: 10 ft
◉ the drain connecting a compartments to a set a fixture to its trap
is called.
Answer: continuous waste
◉ the clearence for a 3 inch clean out.
Answer: 18 inches
,◉ all trenches deeper than the footing of any building and parrelling
the same must be.
Answer: 45 degrees
◉ sleeve shall be provided to protect piping in what wall.
Answer: concrete and masonary
◉ the minimal vertical length of a gravity type venting system
serving a fuel fired water heater.
Answer: 5 feet
◉ the maximum horzontal distance of trap is measured from the
edge of the vent to the.
Answer: weir of the trap
◉ backwater is used to keep?.
Answer: reverse flow of water into the drainage system
◉ water closet ballcocks shall be installed with the vaccum breaker
critical level at.
Answer: 1 inch above the overflow
◉ no indirect waste needs to be larger than the.
, Answer: drain outlet or tail piece of the drain
◉ a water system containing storage water heater equipment will
require.
Answer: tempeature and pressure relief valve
◉ type b water heater vent 4 in in size will terminate above a
horzontal roof no less than.
Answer: 5 feet
◉ copper tubing and fitting installed above ground used for
drainage and vents.
Answer: shall not be not be type m, l, or k
◉ the tempature of water in a tankless water heater shall not be
greater than.
Answer: 140
◉ the pressure at the base of a colum of water 10 ft high.
Answer: 1 cubic feet 4.33 psi
◉ the terminal end of a drain line for a pressure relief valve shall not
be.
WITH SOLVED QUESTIONS
◉ stand pipe receptor for clothes washer will stand above the trap
no less than.
Answer: 18 in
◉ building sewers will be tested by filling.
Answer: from the lowest point to 10ft high
◉ a plumbing vent will terminate no less than how many feet from a
air intake.
Answer: 10 ft
◉ the drain connecting a compartments to a set a fixture to its trap
is called.
Answer: continuous waste
◉ the clearence for a 3 inch clean out.
Answer: 18 inches
,◉ all trenches deeper than the footing of any building and parrelling
the same must be.
Answer: 45 degrees
◉ sleeve shall be provided to protect piping in what wall.
Answer: concrete and masonary
◉ the minimal vertical length of a gravity type venting system
serving a fuel fired water heater.
Answer: 5 feet
◉ the maximum horzontal distance of trap is measured from the
edge of the vent to the.
Answer: weir of the trap
◉ backwater is used to keep?.
Answer: reverse flow of water into the drainage system
◉ water closet ballcocks shall be installed with the vaccum breaker
critical level at.
Answer: 1 inch above the overflow
◉ no indirect waste needs to be larger than the.
, Answer: drain outlet or tail piece of the drain
◉ a water system containing storage water heater equipment will
require.
Answer: tempeature and pressure relief valve
◉ type b water heater vent 4 in in size will terminate above a
horzontal roof no less than.
Answer: 5 feet
◉ copper tubing and fitting installed above ground used for
drainage and vents.
Answer: shall not be not be type m, l, or k
◉ the tempature of water in a tankless water heater shall not be
greater than.
Answer: 140
◉ the pressure at the base of a colum of water 10 ft high.
Answer: 1 cubic feet 4.33 psi
◉ the terminal end of a drain line for a pressure relief valve shall not
be.