Essentials of Fire Fighting 7th Edition
Chapter 13 Hose Operations and Hose
Streams Actual Exam

What type of hose stream has the lowest forward velocity?

A. Solid stream
B. Straight stream
C. Wide-angle fog stream
D. Narrow-angle fog stream - CORRECT ANSWER-C. Wide-angle fog stream

Chapter 13 - page 624

A hose fitting used to connect a smaller-diameter hose line to the end of a larger one is
commonly called a(n):

A. Wye
B. Adapter
C. Reducer
D. Water thief - CORRECT ANSWER-C. Reducer

Chapter 13 - page 601

What statement about dry-barrel hydrants is true?

A. Horizontal compression valves are usually at each outlet
B. They can only be used with pumpers that have drafting capabilities
C. The stem nut used to open and close the control valve is on top of the hydrant
D. They are all designed for use in climates that do not experience freezing
temperatures - CORRECT ANSWER-C. The stem nut used to open and close the
control valve is on top of the hydrant

Chapter 13 - page 588

When a dry-barrel hydrant is open and there is a broken component in the hydrant
barrel, you would see:

A. Water discharging only from the largest outlet
B. Water bubbling up out of the ground at the base
C. Streams of water shooting from the steamer connection

,D. A sucking effect that can be heard from the discharge outlets - CORRECT
ANSWER-B. Water bubbling up out of the ground at the base

Chapter 13 - page 589

What is a consideration for opening wet-barrel and dry-barrel hydrants?

A. The barrels of all hydrants should be drained sufficiently when not in use
B. All hydrants should be opened slowly, but can be closed quickly if necessary
C. Closing a hydrants too quickly can damage piping and appliances of adjacent
residences
D. As the main valve moves up, a drain valve is opened to allow water to drain from the
barrel - CORRECT ANSWER-C. Closing a hydrants too quickly can damage piping and
appliances of adjacent residences

Chapter 13 - page 592

What type of stream is designed for use in attics, cocklofts, basements, and other
confined spaces?

A. Fog
B. Solid
C. Broken
D. Straight - CORRECT ANSWER-C. Broken

Chapter 13 - page 624

What hydrant discharge outlets are considered standard?

A. At least three hose outlets of any size
B. At least two hose outlets for 2 1/2'' couplings
C. At least two large outlets often referred to as steamer connections
D. At least one large outlet (4'' or 4 1/2'') and two hose outlets for 2 1/2'' couplings -
CORRECT ANSWER-D. At least one large outlet (4'' or 4 1/2'') and two hose outlets for
2 1/2'' couplings

Chapter 13 - page 588

What type of valve is used to control the flow from a hydrant?

A. Ball valve
B. Gate valve
C. Clapper valve
D. Butterfly valve - CORRECT ANSWER-B. Gate valve

Chapter 13 - page 600

, Swimming pools, large above-ground animal water tanks, and portable water tanks are
considered to be:

A. Static water sources
B. Temporary drop sites
C. Inadequate sources for drafting operations
D. Access points on water distribution systems - CORRECT ANSWER-A. Static water
sources

Chapter 13 - page 595

The velocity of a stream of water from a smooth bore nozzle is a result of:

A. Hose diameter
B. Pump pressure
C. Nozzle pressure
D. Volume of water - CORRECT ANSWER-C. Nozzle pressure

Chapter 13 - page 615

What type of valve is used on large pump intakes and incorporates a flat baffle that
turns 90 degrees?

A. Ball valve
B. Gate valve
C. Clapper valve
D. Butterfly valve - CORRECT ANSWER-D. Butterfly valve

Chapter 13 - page 600

What is the primary advantage of a nozzle that uses a slide valve?

A. Does not cause turbulence
B. Has no risk of water hammer
C. Can be operated at high pressure
D. Creates the widest variance in stream stypes - CORRECT ANSWER-A. Does not
cause turbulence

Chapter 13 - page 619

An outside stretch improvised standpipe:

A. Can be used for lower floors of high-rise buildings
B. Requires the use of an aerial device to lift the hose line into place
C. Has the advantage of not needing to be secured to anchor points

Document information

Uploaded on
October 1, 2026
Number of pages
17
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$11.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
DOCVAULT
5.0
(1)
Sold
11
Followers
3
Items
1030
Last sold
1 month ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions