CHST Test with all Correct & 100% Verified Answers |
Actual Complete Update |Already Graded A+
employer responsibilities regarding use of GFCI ✔Correct Answer-1. delegate implementation
to 'competent person'
2. 120V which operate at 15 to 20 amps, not permanent, equipe with GFCI
3. applies to all cord sets not part of permanent building struction
4.maintain written description of th eprovisions.
OSHA specification which apply to wire rope used in construction rigging ✔Correct Answer--
no more than three tucks ina wire rope
-wire ropes used for hoisting or lowering be continuous length of rope without knot or splice
except for eye splices at the end
-eyes in wire rope slings or bridles not to be compromised of wire rope clips or knots
-no more than 10% visible broken wires
concerns of 'system safety analysis' ✔Correct Answer-analytical stufy of the interacting
components of a process.
'gas chromatography' ✔Correct Answer--measure environmental toxins in the air
-separates and isolates components of a mixture of gases
-combine with mass spectometer
employee benefits of JSA ✔Correct Answer--supervisor meets with employees
-train in productive and safe operations
-supervisor communicates and apply safety techniques
Footcandles for Gen Constr. concrete placement, excavation, loading platforms, refueling, field
maintenance areas ✔Correct Answer-5
Footcandles for Indoor warehouses, corridors, hallways, and exit ways ✔Correct Answer-5
Footcandles for tunnels, shafts and general underground work areas ✔Correct Answer-5
Footcandles for construction plant and shops, mechanical and electrical equipment rooms,
carpenter shops, rigging lofts and active storerooms ✔Correct Answer-10
Footcandles for Underground operations involving work at a heading involving drilling, mucking,
and scaling ✔Correct Answer-10
Footcandles for First-aid, stations, infirmaries, and offices ✔Correct Answer-30
, Permissible Noise Exposure for 8 hour day ✔Correct Answer-90
Permissible Noise Exposure for 1/4 hour ✔Correct Answer-115
Permissible Noise Exposure for 4 hours ✔Correct Answer-95
Permissible Noise Exposure for 2 hours ✔Correct Answer-100
CFR
10, 16, 23, 29, 40, 42, 49 ✔Correct Answer-10-Energy
16-Consumer Protechtion
23-Highways
29-Construction
40-Environment
42-Public Health
49-Transportation
Fire Class
A-B-C-D-K ✔Correct Answer-A-Ordinary sold combustibles (ash)
B-Flammable liquids (barrel)
C-Energized electrical equip (current)
D-Combustible metals
K-Oils and Fats (kitchen)
OSHA for 300 ✔Correct Answer-Log of Work Related Injuries and Illnesses
a- case number g-death
b-name h-days away
c-job site i-job transfer
d-date j-other
e-where k-away
f-describe l-on job trans
1-6 type of injury or illness
OSHA 300a Summery of Wrk-Related Injuries and Illnesses ✔Correct Answer-posted February
1 to April 30
OSHA 301 Injury and Illness Incident Report ✔Correct Answer-within 7 days you receive info
of illness or injury
keep on file for 5 years following the year
ACGIH ✔Correct Answer-American Conference of Governmental Industrial Hygienest
RCRA ✔Correct Answer-Resource Conservation and Recovery Act: governing the disposal of
solid waste adn hazardous waste
Actual Complete Update |Already Graded A+
employer responsibilities regarding use of GFCI ✔Correct Answer-1. delegate implementation
to 'competent person'
2. 120V which operate at 15 to 20 amps, not permanent, equipe with GFCI
3. applies to all cord sets not part of permanent building struction
4.maintain written description of th eprovisions.
OSHA specification which apply to wire rope used in construction rigging ✔Correct Answer--
no more than three tucks ina wire rope
-wire ropes used for hoisting or lowering be continuous length of rope without knot or splice
except for eye splices at the end
-eyes in wire rope slings or bridles not to be compromised of wire rope clips or knots
-no more than 10% visible broken wires
concerns of 'system safety analysis' ✔Correct Answer-analytical stufy of the interacting
components of a process.
'gas chromatography' ✔Correct Answer--measure environmental toxins in the air
-separates and isolates components of a mixture of gases
-combine with mass spectometer
employee benefits of JSA ✔Correct Answer--supervisor meets with employees
-train in productive and safe operations
-supervisor communicates and apply safety techniques
Footcandles for Gen Constr. concrete placement, excavation, loading platforms, refueling, field
maintenance areas ✔Correct Answer-5
Footcandles for Indoor warehouses, corridors, hallways, and exit ways ✔Correct Answer-5
Footcandles for tunnels, shafts and general underground work areas ✔Correct Answer-5
Footcandles for construction plant and shops, mechanical and electrical equipment rooms,
carpenter shops, rigging lofts and active storerooms ✔Correct Answer-10
Footcandles for Underground operations involving work at a heading involving drilling, mucking,
and scaling ✔Correct Answer-10
Footcandles for First-aid, stations, infirmaries, and offices ✔Correct Answer-30
, Permissible Noise Exposure for 8 hour day ✔Correct Answer-90
Permissible Noise Exposure for 1/4 hour ✔Correct Answer-115
Permissible Noise Exposure for 4 hours ✔Correct Answer-95
Permissible Noise Exposure for 2 hours ✔Correct Answer-100
CFR
10, 16, 23, 29, 40, 42, 49 ✔Correct Answer-10-Energy
16-Consumer Protechtion
23-Highways
29-Construction
40-Environment
42-Public Health
49-Transportation
Fire Class
A-B-C-D-K ✔Correct Answer-A-Ordinary sold combustibles (ash)
B-Flammable liquids (barrel)
C-Energized electrical equip (current)
D-Combustible metals
K-Oils and Fats (kitchen)
OSHA for 300 ✔Correct Answer-Log of Work Related Injuries and Illnesses
a- case number g-death
b-name h-days away
c-job site i-job transfer
d-date j-other
e-where k-away
f-describe l-on job trans
1-6 type of injury or illness
OSHA 300a Summery of Wrk-Related Injuries and Illnesses ✔Correct Answer-posted February
1 to April 30
OSHA 301 Injury and Illness Incident Report ✔Correct Answer-within 7 days you receive info
of illness or injury
keep on file for 5 years following the year
ACGIH ✔Correct Answer-American Conference of Governmental Industrial Hygienest
RCRA ✔Correct Answer-Resource Conservation and Recovery Act: governing the disposal of
solid waste adn hazardous waste