Building sewers shall be tested by completely filling the sewer with water from the ______________ . -
(answer)Lowest to at least a ten-foot head



Hot and cold-water piping may be tested with _________________ . - (answer)50 psi or the working
pressure of the water in the system for at least 15 minutes



The required clearance in front of a three-inch cleanout is ______________ . - (answer)18 inches



A stack as defined in the code is ______________ . - (answer)The vertical main of a soil, waste or vent
piping which extends one or more stories



Above ground PEX piping installed horizontally shall be supported at intervals not to exceed
______________ . - (answer)32 inches



The minimum true vertical length for a gravity type venting system serving a fuel fired water heater is
_______________ . - (answer)5 feet



The maximum horizontal distance of a trap arm is measured from the inner edge of the vent to the
__________________ . - (answer)Weir of the trap



Sleeves shall be provided to protect piping ____________ . - (answer)Passing through concrete and
masonry walls



The drain connecting the compartments of a set of fixtures to its trap is called a/an
____________________ . - (answer)Continuous waste



A device to prevent backflow into the potable water system is called a/an _________ . -
(answer)Backflow preventer

,TSPBE PLUMBING INSPECTOR PRACTICE SET BRAND NEW ACTUAL
EXAM WITH 100% VERIFIED QUESTIONS AND CORRECT SOLUTIONS



Copper tube and fittings used for drainage and vent piping installed above ground shall be at least
_____________ . - (answer)Type DWV



All trenches deeper than the footing of any building or structure and paralleling the same must be at
least _____________ . - (answer)45 degrees therefrom



The minimum size trap and trap arm for a kitchen sink is _____________ . - (answer)1 1/2 inches



Horizontal drainage lines connecting with other horizontal drainage lines shall enter through
____________ . - (answer)45 degree wye branches



For each run of horizontal drain piping, the distance between cleanouts shall not exceed
______________ . - (answer)100 feet



A plumbing vent shall terminate not less than _____________ . - (answer)10 feet from an air intake



Each drainage stack which extends 5 or more stories above the building drain shall be served by
_____________ . - (answer)A parallel vent stack



Chemical or industrial liquid wastes which are likely to damage the public sanitary sewer system shall be
______________ . - (answer)Pretreated to render then innocuous



Special venting for island fixtures is used for _________ . - (answer)Kitchen sinks



The vertical distance between a fixture outlet and the trap weir (tailpiece) shall not exceed
____________ . - (answer)24 inches



Fixture traps shall have a water seal of not less than ______________ . - (answer)2 inches

,TSPBE PLUMBING INSPECTOR PRACTICE SET BRAND NEW ACTUAL
EXAM WITH 100% VERIFIED QUESTIONS AND CORRECT SOLUTIONS



Concealed slip joint connections require a/an ________________ . - (answer)12 x 12 access panel



The distance from the center of a water closet to a sidewall shall not be closer than
___________________ . - (answer)15 inches



The depth of the finished dam or threshold for any shower, measured from the top of the drain, shall not
be less than _________________ . - (answer)2 inches



The critical level of a urinal flushometer vacuum breaker to the highest part of the fixture is
_________________ . - (answer)6 inches



Water closet tank ballcocks shall be installed with the vacuum breaker critical level at least
_________________________ . - (answer)1 inch above the full opening of the overflow tube



A pressure regulator with a strainer is required when the local water pressure is in excess of
_____________________ . - (answer)80 psi



A water system containing storage water heating equipment will require a ___________________ . -
(answer)Listed combination temperature and pressure relief valve



The terminal end of a drain line for a pressure relief valve shall not be _______________ . -
(answer)Threaded



Gas piping supplying more than one building on any one premise shall be equipped with
___________________ . - (answer)Separate shutoff valves to each building



The maximum distance of a gas shutoff valve may be from a gas appliance is _____________ . -
(answer)6 feet

, TSPBE PLUMBING INSPECTOR PRACTICE SET BRAND NEW ACTUAL
EXAM WITH 100% VERIFIED QUESTIONS AND CORRECT SOLUTIONS



The minimum size of any gas piping outlet for a free-standing gas range shall be _______________ . -
(answer)3/4 inch



Type B water heater vents, 4 inches in size, shall terminate above a horizontal roof no less than
_______________ . - (answer)12 inches



All gas water heaters or other gas appliances that are connected to a common vent shall be located
_______________ . - (answer)In the same story



Every passageway to an attic water heater shall have solid continuous flooring not less than
_______________ . - (answer)24 inches wide



A plumbing permit expires if work authorized by the permit is not started within _____________ . -
(answer)180 days



A plumbing permit is not required ______________ . - (answer)For cleaning stoppages



Gas shutoff valves are required at supply connections to all ________________ . - (answer)Gas burning
appliances



A fixture trap is vented to _______________ . - (answer)Prevent the loss of trap seal, reduce noise in the
drainage system, prevent siphonage or backpressure to a trap



A device is located at the bottom of the tank for the purposes of flushing water closets is
_________________ . - (answer)Flush valve



In sizing gas piping, the developed length is measured from the meter location to ________________ . -
(answer)The most remote outlet on the system

Document information

Uploaded on
September 24, 2026
Number of pages
33
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
Free
Download

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
4193
Followers
0
Items
490
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions