Michigan Builders License Exam
LATEST UPDATES!!! 2026-2027 |
CORRECT SOLUTIONS WITH QUIZ &
ANSWERS | HIGHLY GRADED A+
Created to serve as a complete, comprehensive code regulating the construction of
single-family, two-family and buildings consisting of three or more townhouse units. -
CORRECT ANSWERS-IRC (International Residential Code)
Administrative - CORRECT ANSWERS-First 2 chapters of code book are
True - CORRECT ANSWERS-Plans or supporting documents are almost always
required by the controlling authority prior to issuing a permit. T or F
Yes - CORRECT ANSWERS-Does the building official have the authority to render
interpretations of the code?
8 foot fence. - CORRECT ANSWERS-None of the following require a permit, EXCEPT:
sidewalks and driveways
tiling
an 8 foot fence
playground equipment
False - CORRECT ANSWERS-Tables and illustrations are always supported by
information found in the written code and footnotes. T or F
Live load. - CORRECT ANSWERS-The amount of evenly distributed weight imposed by
inhabitants, goods and removable objects on a floor or roof system is referred to as
True. - CORRECT ANSWERS-If a code requirement is in the book, it is both acceptable
and enforceable by the code official. T or F
Figures. - CORRECT ANSWERS-Illustrations are typically referred to as
Determine that buildings are built to the minimum enforceable standard. - CORRECT
ANSWERS-Generally speaking, the building official's job is to
,True. - CORRECT ANSWERS-It is required that all manufacturer instructions be at the
jobsite at the time of inspection. T or F
Kitchen. - CORRECT ANSWERS-All of the following are not considered habitable
spaces EXCEPT:
bathrooms
kitchens
storage spaces
closets
3. - CORRECT ANSWERS-Bathrooms must be provided with an aggregate glazing
area no less than _____ square feet, half of which must be openable.
44 inches. - CORRECT ANSWERS-The maximum height of an egress window above
the floor is
5.7 sq ft. - CORRECT ANSWERS-A basement bedroom must have an egress window
with a clear opening of at least ______ square feet.
3. - CORRECT ANSWERS-At least one side-hinged exit door must be in each dwelling
unit, and must be _____ feet wide.
30 inches. - CORRECT ANSWERS-A porch more than _____ inches above grade must
be provided with 36" guards.
200. - CORRECT ANSWERS-Wall and ceiling finishes shall have a flame-spread
classification of no more than ______ .
7 days. - CORRECT ANSWERS-According to code, concrete must reach at least 70%
of it's ability within ____________days.
40%. - CORRECT ANSWERS-A stud used for a non-bearing partitions may not be
notched more than ____% of the stud width.
Additions, alterations, renovation and repairs. - CORRECT ANSWERS-The Michigan
Uniform Energy code applies to new buildings as well as
U-factor. - CORRECT ANSWERS-___________ is a measure of how well the window
or door assembly conducts heat. The lower the number, the better insulation the
assembly will provide.
50%. - CORRECT ANSWERS-Energy losses from recessed lighting fixtures can often
reach ___% of the total thermal loss of a ceiling.
R-3. - CORRECT ANSWERS-Michigan requires a minimum thermal resistance of
____________for mechanical system piping.
,True. - CORRECT ANSWERS-Oversized HVAC equipment has a higher initial cost, a
higher operating cost, provides less comfort, and shorter life expectancy. T or F
Prescriptive Path. - CORRECT ANSWERS-_______ is the compliance route that
applies Table 402.1.1 to building envelope components, and is considered the most
simple.
Area weighted averages. - CORRECT ANSWERS-___________ can be used to satisfy
U-factor and SHGC requirements.
IC (Insulation Contact) - CORRECT ANSWERS-Recessed lights must be _____ rated.
True. - CORRECT ANSWERS-Up to 15 square feet of glazing per dwelling unit is
exempted from U-value requirements. T or F
Registered design professional. - CORRECT ANSWERS-The 2009 IECC requires a
permanent certificate posted on the electrical distribution panel. The certificate shall be
completed by the builder or
State energy code requirements. - CORRECT ANSWERS-One hurdle contractors face
when bidding for an energy efficient project is choosing materials that fit the design, and
also meet
False. - CORRECT ANSWERS-Historically significant buildings are not exempt from
code changes. T or F
R-value
Settled thickness
Manufacturer name - CORRECT ANSWERS-Insulation products (blown and sprayed)
must be documented with:
March 2011. - CORRECT ANSWERS-The new Michigan codes took effect in
10. - CORRECT ANSWERS-Below grade walls are insulated from the top of the
basement wall down to _____ below grade, or the basement floor, whichever is less.
Area weighted average. - CORRECT ANSWERS-The _______ is the combined Solar
Heat Gain Coefficient of all the glazed fenestration products in the building.
Thermal insulation R-values
Design criteria
Equipment systems - CORRECT ANSWERS-Plans and specifications must be detailed
in regards to:
, 2009. - CORRECT ANSWERS-In Michigan, the residential energy code is based on the
_____ IECC, with certain amendments.
Air leakage. - CORRECT ANSWERS-___________ is the rate of air infiltration in the
presence of a specific pressure differential.
Windows
Attic access hatches
Recessed lights - CORRECT ANSWERS-Air leakage is the random movement of air
into and out of ________ through cracks and holes.
Table 402.1.1
2009 IECC - CORRECT ANSWERS-R-values for insulation and fenestration
requirements by component can be found in
International Energy Conservation Code - CORRECT ANSWERS-IECC
U-factor and UA alternatives. - CORRECT ANSWERS-The _____________ compliance
method allows for more innovative construction techniques like SIPs or Advanced
Framing.
500 sq feet - CORRECT ANSWERS-R-30 is permitted in vaulted ceilings, but is limited
to
True. - CORRECT ANSWERS-Floor insulation must be installed to maintain permanent
and continuous contact with the underside of the subfloor decking. T or F
5, 6 and 7. - CORRECT ANSWERS-Michigan falls into climate zones
False. - CORRECT ANSWERS-It is permissible for supply ducts to be run through the
framing cavities of a residential building. T or F
IC rated (Insulation Contact) - CORRECT ANSWERS-__________ means an electrical
fixture has been tested and listed as suitable for installation in a cavity where the fixture
may come in contact with insulation.
3%. - CORRECT ANSWERS-According to the Dept. of Energy, improved energy codes
could reduce CO2 emissions by
300 sq ft. - CORRECT ANSWERS-Attic insulation markers must be installed every
_____ square feet.
True. - CORRECT ANSWERS-Buildings that are exempted from the new regulations
are those with very low energy use or ones that are neither heated or cooled. T or F
LATEST UPDATES!!! 2026-2027 |
CORRECT SOLUTIONS WITH QUIZ &
ANSWERS | HIGHLY GRADED A+
Created to serve as a complete, comprehensive code regulating the construction of
single-family, two-family and buildings consisting of three or more townhouse units. -
CORRECT ANSWERS-IRC (International Residential Code)
Administrative - CORRECT ANSWERS-First 2 chapters of code book are
True - CORRECT ANSWERS-Plans or supporting documents are almost always
required by the controlling authority prior to issuing a permit. T or F
Yes - CORRECT ANSWERS-Does the building official have the authority to render
interpretations of the code?
8 foot fence. - CORRECT ANSWERS-None of the following require a permit, EXCEPT:
sidewalks and driveways
tiling
an 8 foot fence
playground equipment
False - CORRECT ANSWERS-Tables and illustrations are always supported by
information found in the written code and footnotes. T or F
Live load. - CORRECT ANSWERS-The amount of evenly distributed weight imposed by
inhabitants, goods and removable objects on a floor or roof system is referred to as
True. - CORRECT ANSWERS-If a code requirement is in the book, it is both acceptable
and enforceable by the code official. T or F
Figures. - CORRECT ANSWERS-Illustrations are typically referred to as
Determine that buildings are built to the minimum enforceable standard. - CORRECT
ANSWERS-Generally speaking, the building official's job is to
,True. - CORRECT ANSWERS-It is required that all manufacturer instructions be at the
jobsite at the time of inspection. T or F
Kitchen. - CORRECT ANSWERS-All of the following are not considered habitable
spaces EXCEPT:
bathrooms
kitchens
storage spaces
closets
3. - CORRECT ANSWERS-Bathrooms must be provided with an aggregate glazing
area no less than _____ square feet, half of which must be openable.
44 inches. - CORRECT ANSWERS-The maximum height of an egress window above
the floor is
5.7 sq ft. - CORRECT ANSWERS-A basement bedroom must have an egress window
with a clear opening of at least ______ square feet.
3. - CORRECT ANSWERS-At least one side-hinged exit door must be in each dwelling
unit, and must be _____ feet wide.
30 inches. - CORRECT ANSWERS-A porch more than _____ inches above grade must
be provided with 36" guards.
200. - CORRECT ANSWERS-Wall and ceiling finishes shall have a flame-spread
classification of no more than ______ .
7 days. - CORRECT ANSWERS-According to code, concrete must reach at least 70%
of it's ability within ____________days.
40%. - CORRECT ANSWERS-A stud used for a non-bearing partitions may not be
notched more than ____% of the stud width.
Additions, alterations, renovation and repairs. - CORRECT ANSWERS-The Michigan
Uniform Energy code applies to new buildings as well as
U-factor. - CORRECT ANSWERS-___________ is a measure of how well the window
or door assembly conducts heat. The lower the number, the better insulation the
assembly will provide.
50%. - CORRECT ANSWERS-Energy losses from recessed lighting fixtures can often
reach ___% of the total thermal loss of a ceiling.
R-3. - CORRECT ANSWERS-Michigan requires a minimum thermal resistance of
____________for mechanical system piping.
,True. - CORRECT ANSWERS-Oversized HVAC equipment has a higher initial cost, a
higher operating cost, provides less comfort, and shorter life expectancy. T or F
Prescriptive Path. - CORRECT ANSWERS-_______ is the compliance route that
applies Table 402.1.1 to building envelope components, and is considered the most
simple.
Area weighted averages. - CORRECT ANSWERS-___________ can be used to satisfy
U-factor and SHGC requirements.
IC (Insulation Contact) - CORRECT ANSWERS-Recessed lights must be _____ rated.
True. - CORRECT ANSWERS-Up to 15 square feet of glazing per dwelling unit is
exempted from U-value requirements. T or F
Registered design professional. - CORRECT ANSWERS-The 2009 IECC requires a
permanent certificate posted on the electrical distribution panel. The certificate shall be
completed by the builder or
State energy code requirements. - CORRECT ANSWERS-One hurdle contractors face
when bidding for an energy efficient project is choosing materials that fit the design, and
also meet
False. - CORRECT ANSWERS-Historically significant buildings are not exempt from
code changes. T or F
R-value
Settled thickness
Manufacturer name - CORRECT ANSWERS-Insulation products (blown and sprayed)
must be documented with:
March 2011. - CORRECT ANSWERS-The new Michigan codes took effect in
10. - CORRECT ANSWERS-Below grade walls are insulated from the top of the
basement wall down to _____ below grade, or the basement floor, whichever is less.
Area weighted average. - CORRECT ANSWERS-The _______ is the combined Solar
Heat Gain Coefficient of all the glazed fenestration products in the building.
Thermal insulation R-values
Design criteria
Equipment systems - CORRECT ANSWERS-Plans and specifications must be detailed
in regards to:
, 2009. - CORRECT ANSWERS-In Michigan, the residential energy code is based on the
_____ IECC, with certain amendments.
Air leakage. - CORRECT ANSWERS-___________ is the rate of air infiltration in the
presence of a specific pressure differential.
Windows
Attic access hatches
Recessed lights - CORRECT ANSWERS-Air leakage is the random movement of air
into and out of ________ through cracks and holes.
Table 402.1.1
2009 IECC - CORRECT ANSWERS-R-values for insulation and fenestration
requirements by component can be found in
International Energy Conservation Code - CORRECT ANSWERS-IECC
U-factor and UA alternatives. - CORRECT ANSWERS-The _____________ compliance
method allows for more innovative construction techniques like SIPs or Advanced
Framing.
500 sq feet - CORRECT ANSWERS-R-30 is permitted in vaulted ceilings, but is limited
to
True. - CORRECT ANSWERS-Floor insulation must be installed to maintain permanent
and continuous contact with the underside of the subfloor decking. T or F
5, 6 and 7. - CORRECT ANSWERS-Michigan falls into climate zones
False. - CORRECT ANSWERS-It is permissible for supply ducts to be run through the
framing cavities of a residential building. T or F
IC rated (Insulation Contact) - CORRECT ANSWERS-__________ means an electrical
fixture has been tested and listed as suitable for installation in a cavity where the fixture
may come in contact with insulation.
3%. - CORRECT ANSWERS-According to the Dept. of Energy, improved energy codes
could reduce CO2 emissions by
300 sq ft. - CORRECT ANSWERS-Attic insulation markers must be installed every
_____ square feet.
True. - CORRECT ANSWERS-Buildings that are exempted from the new regulations
are those with very low energy use or ones that are neither heated or cooled. T or F