Michigan Builders License Exam
LATEST UPDATES!!! 2026-2027 |
CORRECT SOLUTIONS WITH QUIZ &
ANSWERS | HIGHLY GRADED A+

Created to serve as a complete, comprehensive code regulating the construction of
single-family, two-family and buildings consisting of three or more townhouse units. -
CORRECT ANSWERS-IRC (International Residential Code)

Administrative - CORRECT ANSWERS-First 2 chapters of code book are

True - CORRECT ANSWERS-Plans or supporting documents are almost always
required by the controlling authority prior to issuing a permit. T or F

Yes - CORRECT ANSWERS-Does the building official have the authority to render
interpretations of the code?

8 foot fence. - CORRECT ANSWERS-None of the following require a permit, EXCEPT:
sidewalks and driveways
tiling
an 8 foot fence
playground equipment

False - CORRECT ANSWERS-Tables and illustrations are always supported by
information found in the written code and footnotes. T or F

Live load. - CORRECT ANSWERS-The amount of evenly distributed weight imposed by
inhabitants, goods and removable objects on a floor or roof system is referred to as

True. - CORRECT ANSWERS-If a code requirement is in the book, it is both acceptable
and enforceable by the code official. T or F

Figures. - CORRECT ANSWERS-Illustrations are typically referred to as

Determine that buildings are built to the minimum enforceable standard. - CORRECT
ANSWERS-Generally speaking, the building official's job is to

,True. - CORRECT ANSWERS-It is required that all manufacturer instructions be at the
jobsite at the time of inspection. T or F

Kitchen. - CORRECT ANSWERS-All of the following are not considered habitable
spaces EXCEPT:
bathrooms
kitchens
storage spaces
closets

3. - CORRECT ANSWERS-Bathrooms must be provided with an aggregate glazing
area no less than _____ square feet, half of which must be openable.

44 inches. - CORRECT ANSWERS-The maximum height of an egress window above
the floor is

5.7 sq ft. - CORRECT ANSWERS-A basement bedroom must have an egress window
with a clear opening of at least ______ square feet.

3. - CORRECT ANSWERS-At least one side-hinged exit door must be in each dwelling
unit, and must be _____ feet wide.

30 inches. - CORRECT ANSWERS-A porch more than _____ inches above grade must
be provided with 36" guards.

200. - CORRECT ANSWERS-Wall and ceiling finishes shall have a flame-spread
classification of no more than ______ .

7 days. - CORRECT ANSWERS-According to code, concrete must reach at least 70%
of it's ability within ____________days.

40%. - CORRECT ANSWERS-A stud used for a non-bearing partitions may not be
notched more than ____% of the stud width.

Additions, alterations, renovation and repairs. - CORRECT ANSWERS-The Michigan
Uniform Energy code applies to new buildings as well as

U-factor. - CORRECT ANSWERS-___________ is a measure of how well the window
or door assembly conducts heat. The lower the number, the better insulation the
assembly will provide.

50%. - CORRECT ANSWERS-Energy losses from recessed lighting fixtures can often
reach ___% of the total thermal loss of a ceiling.

R-3. - CORRECT ANSWERS-Michigan requires a minimum thermal resistance of
____________for mechanical system piping.

,True. - CORRECT ANSWERS-Oversized HVAC equipment has a higher initial cost, a
higher operating cost, provides less comfort, and shorter life expectancy. T or F

Prescriptive Path. - CORRECT ANSWERS-_______ is the compliance route that
applies Table 402.1.1 to building envelope components, and is considered the most
simple.

Area weighted averages. - CORRECT ANSWERS-___________ can be used to satisfy
U-factor and SHGC requirements.

IC (Insulation Contact) - CORRECT ANSWERS-Recessed lights must be _____ rated.

True. - CORRECT ANSWERS-Up to 15 square feet of glazing per dwelling unit is
exempted from U-value requirements. T or F

Registered design professional. - CORRECT ANSWERS-The 2009 IECC requires a
permanent certificate posted on the electrical distribution panel. The certificate shall be
completed by the builder or

State energy code requirements. - CORRECT ANSWERS-One hurdle contractors face
when bidding for an energy efficient project is choosing materials that fit the design, and
also meet

False. - CORRECT ANSWERS-Historically significant buildings are not exempt from
code changes. T or F

R-value
Settled thickness
Manufacturer name - CORRECT ANSWERS-Insulation products (blown and sprayed)
must be documented with:

March 2011. - CORRECT ANSWERS-The new Michigan codes took effect in

10. - CORRECT ANSWERS-Below grade walls are insulated from the top of the
basement wall down to _____ below grade, or the basement floor, whichever is less.

Area weighted average. - CORRECT ANSWERS-The _______ is the combined Solar
Heat Gain Coefficient of all the glazed fenestration products in the building.

Thermal insulation R-values
Design criteria
Equipment systems - CORRECT ANSWERS-Plans and specifications must be detailed
in regards to:

, 2009. - CORRECT ANSWERS-In Michigan, the residential energy code is based on the
_____ IECC, with certain amendments.

Air leakage. - CORRECT ANSWERS-___________ is the rate of air infiltration in the
presence of a specific pressure differential.

Windows
Attic access hatches
Recessed lights - CORRECT ANSWERS-Air leakage is the random movement of air
into and out of ________ through cracks and holes.

Table 402.1.1
2009 IECC - CORRECT ANSWERS-R-values for insulation and fenestration
requirements by component can be found in

International Energy Conservation Code - CORRECT ANSWERS-IECC

U-factor and UA alternatives. - CORRECT ANSWERS-The _____________ compliance
method allows for more innovative construction techniques like SIPs or Advanced
Framing.

500 sq feet - CORRECT ANSWERS-R-30 is permitted in vaulted ceilings, but is limited
to

True. - CORRECT ANSWERS-Floor insulation must be installed to maintain permanent
and continuous contact with the underside of the subfloor decking. T or F

5, 6 and 7. - CORRECT ANSWERS-Michigan falls into climate zones

False. - CORRECT ANSWERS-It is permissible for supply ducts to be run through the
framing cavities of a residential building. T or F

IC rated (Insulation Contact) - CORRECT ANSWERS-__________ means an electrical
fixture has been tested and listed as suitable for installation in a cavity where the fixture
may come in contact with insulation.

3%. - CORRECT ANSWERS-According to the Dept. of Energy, improved energy codes
could reduce CO2 emissions by

300 sq ft. - CORRECT ANSWERS-Attic insulation markers must be installed every
_____ square feet.

True. - CORRECT ANSWERS-Buildings that are exempted from the new regulations
are those with very low energy use or ones that are neither heated or cooled. T or F

Document information

Uploaded on
September 24, 2026
Number of pages
55
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$18.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
kenmuthie
1.0
(1)
Sold
3
Followers
0
Items
389
Last sold
4 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions