LFTI COMPREHENSIVE ANSWERS AND QUESTIONS
SET A+
✔✔shall play the role of a victim inside the building. - ✔✔37. No person (s)

✔✔How many fires at a time shall be permitted within an acquired structure. (1403
4.4.15) - ✔✔38. Only one fire

✔✔to reduce the risk of injury or illness caused by extreme weather conditions. (1403
4.4.16) - ✔✔39. The training session shall be curtailed, postponed, or canceled

✔✔40. SCBAs shall be used in an atmosphere that is - ✔✔suspected to be, or can
become oxygen deficient or contaminated by products of combustion, or below ground.
(1403 4.4.17.7)

✔✔Who can be designated as the "ignition officer" to control the materials being
burned. (1403 4.4.18) - ✔✔41. One person who is not a student

✔✔42. The decision to ignite the training fire shall be made by - ✔✔the instructor-in-
charge in coordination with the safety officer. (1403 4.4.18.3)

✔✔43. The fire shall be ignited by the - ✔✔ignition officer in the presence of and under
the direct supervision of the safety officer. (1403 4.4.18.4)

✔✔44. The participating student-to-instructor ratio shall - ✔✔shall not be greater than 5
to 1. (1403 4.5.2)

✔✔when factors such as extreme temperatures or large groups are present, and
classes of long duration are planned. (1403 4.5.3) - ✔✔45. Additional instructors shall
be designated

, ✔✔Who shall do a head count when entering and exiting the building during an actual
attack evolution conducted in accordance with this standard. (1403 4.5.6) -
✔✔Instructors

✔✔47. Part of the burn building evaluation shall include, once every five years - ✔✔the
removal and reinstallation of a representative area of thermal linings (if any) to inspect
the hidden conditions behind the linings. (1403 5.2.2.3)

✔✔48. The engineer shall core solid structural concrete slabs and walls that have been
exposed to temperatures in excess of___\\__ to check for hidden delamination and to
test comprehensive strength once every 10 years for conventional (Portland) concrete
and every three years for refractory (calcium aluminate) concrete. (1403 5.2.2.4) -
✔✔300•

✔✔49. For burn buildings that contain gas-fueled systems, the instructors shall run the
burn center - ✔✔to exposing students to live flames in order to ensure the correct
operation of devices such as gas valves, flame safeguard units, agent sensors,
combustion fans, and ventilation fans. (1403 5.2.5)

✔✔50. Fires shall not be located in - ✔✔any designated exit paths. (1403 All training
buildings)

✔✔shall be checked prior to any live fire evolutions to ensure they operate correctly.
(1403 All training buildings/props) - ✔✔51. All safety devices, such as thermometers,
oxygen and toxic and combustible gas monitors, evacuation alarms, and emergency
shutdown switches,

✔✔52. There shall be room provided around all props so that - ✔✔there is space for all
attack lines as well as backup lines to operate freely. (1403 7.2.27)

✔✔53. For flammable metal fires, there shall be a sufficient quantity of the proper
extinguishing agent available so that - ✔✔all attack crews have adequate supply as well
as a 150% reserve for the use of the backup crews. (1403 7.3.16)

✔✔54. All props that use pressure to move fuel to the fire shall be equipped with -
✔✔54. Lkkiremote fuel shutoffs outside of the safety perimeter but within sight of the
prop and the entire field of attack for the prop. (1403 8.3.9)

✔✔55. Where the evolution involves failure of a safety feature, the failed part shall be -
✔✔located downstream from the properly functioning safety feature. (1403 8.3.12)

✔✔56. Measures shall be taken where using flammable or combustible liquids - ✔✔to
prevent runoff from contaminating the surrounding area. (1403 8.3.13)

Document information

Uploaded on
September 24, 2026
Number of pages
6
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$18.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Pyramids
4.0
(2)
Sold
22
Followers
4
Items
7805
Last sold
1 month ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions