• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 3 out of 25 pages
Exam (elaborations)

ASE T6 Practice Test #1 comprehensive Questions and Answers with Verified Solutions

Document preview thumbnail
Preview 3 out of 25 pages

ASE T6 Practice Test #1 comprehensive Questions and Answers with Verified Solutions

Content preview

ASE T6 Practice Test #1 comprehensive
Questions and Answers with Verified
Solutions
Question 1:
A resistance test was performed on an open toggle switch and the result
is 5.857 megohms . Technician A says that the switch is faulty because
the reading is beyond the specifications . Technician B says that the
switch has over 5 million ohms of resistance . Who is correct ? A. A only
B. B only C. Both A and B D. Neither A nor B

Answer:
Answer A is incorrect . An open switch is supposed to have very high
resistance . Answer B is correct . Only Technician B is correct . The
reading is over 5 million ohms . An open switch should have very high
resistance . Answer C is incorrect . Only Technician B is correct . Answer
D is incorrect . Technician B is correct .


Question 2:
The 12 volt battery in the figure is fully charged and the switch is closed .
Which of the following conditions would be the most likely cause of this
measurement ? A. Larger than specified wire used in wire repair B. Loose
ground for the bulb




Answer:
Answer A is incorrect . A larger wire used in a wire repair would not cause
a voltage loss . Answer B is correct . A loose ground for the bulb could
cause a voltage loss at the ground connection . Performing a voltage
drop test on the ground circuit could isolate this problem . Answer C is

,incorrect . A blown fuse would prevent any voltage from getting past the
fuse contacts . Answer D is incorrect . There is no evidence that the bulb
is faulty . The meter shows only 9 volts being dropped across the bulb .


Question 3:
Which of the following conditions could cause the power locks to fail to
operate ? A. Broken connector at the power lock switch B. Closed power
lock circuit breaker C. An oversized fuse D. An oversized wire repair in
the power lock circuit

Answer:
Answer A is correct . A broken connector at the power lock switch could
cause the power locks to be inoperative because it would likely create an
open circuit . Answer B is incorrect . A closed power lock circuit breaker
would allow normal operation of the power door locks . Answer C is
incorrect . An oversized fuse would allow the power door locks to function
. For safety reasons , however , a technician should never install a fuse
that has a larger rating than the specification . Answer D is incorrect . An
oversized wire would not hinder the operation of the power door locks .

, Question 4:
When using a 12 volt , unpowered test lamp to test for voltage , all of the
following are true EXCEPT : A. The test lamp may be connected to the
battery ground . B. The battery should first be disconnected . C. The test
lamp may be connected to a chassis ground . D. The test lamp will not
illuminate when probed

Answer:
Answer A is incorrect . A 12 volt unpowered test lamp can be connected
to the battery ground cable or any quality ground on the truck . Answer B
is correct . The test light would not operate if the battery were
disconnected . Answer C is incorrect . A 12 volt unpowered test lamp can
be connected to the chassis ground or any quality ground on the truck .
Answer D is incorrect . The voltage level will drop to near zero at points
past the load , causing the test lamp to not illuminate if probed into this
part of the circuit.


Question 5:
After removing a 30 amp circuit breaker from a fuse panel , a technician
checks continuity across its terminals with a digital multimeter ( DMM ) .
Technician A says that the current from the ohmmeter will open the circuit
breaker . Technician B says the ohmmeter should read infinity if the
circuit breaker is good . Who is correct ? A. A only B. B only C. Both A
and B D. Neither A nor B

Answer:
Answer A is incorrect . The small amount of current supplied by an
ohmmeter would not cause a good circuit breaker to open up . Answer B
is incorrect . The ohmmeter should read low resistance on a good circuit
breaker Answer C is incorrect . Neither Technician is correct . Answer D
is correct . Neither Technician is correct . Using an ohmmeter to test a
circuit breaker will not cause the contacts to open up because the current
from the meter will be very small . A good circuit breaker will have a low
reading when being tested with an ohmmeter .

Document information

Uploaded on
September 23, 2026
Number of pages
25
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$14.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
0
Followers
0
Items
199
Last sold
-



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions