What is the purpose of fire warning equipment? - ANSWERSTo provide a reliable means of notifying occupants of the presence of fire and of the need to escape. What are the 3 basic requirements for all devices? - ANSWERS1. They must be approved and listed for the purposes for which they are intended 2. All devices will be installed according to manufacturers recommendations 3. The required minimum and location of detectors shall be satisfied. What is the emergency evacuation signal that shall be used? - ANSWERSANSI S3.41, or American National Standard Emergency Evacuation Signal Can the emergency evacuation signal be used for other devices? - ANSWERSYes, so long as those devices are used to indicate the need for evacuation When can fire warning equipment incorporate voice notification? - ANSWERSWhen the voice message is completely contained within the 1.5 second pause of the emergency evacuation signal. When the voice message is first preceded by a minimum of 8 cycles of the emergency evacuation signal When the voice message interrupts the emergency evacuation signal for no longer than 10 seconds, and is followed by 2 cycles of the emergency evacuation signal. Whose responsibility is it to inform a technician of occupants with hearing disabilities? - ANSWERSThe hearing impaired party

Content preview

TFM 13 QUESTIONS WITH ACCURATE
ANSWERS

What is the purpose of fire warning equipment? - ANSWERSTo provide a reliable
means of notifying occupants of the presence of fire and of the need to escape.

What are the 3 basic requirements for all devices? - ANSWERS1. They must be
approved and listed for the purposes for which they are intended
2. All devices will be installed according to manufacturers recommendations
3. The required minimum and location of detectors shall be satisfied.

What is the emergency evacuation signal that shall be used? - ANSWERSANSI S3.41,
or American National Standard Emergency Evacuation Signal

Can the emergency evacuation signal be used for other devices? - ANSWERSYes, so
long as those devices are used to indicate the need for evacuation

When can fire warning equipment incorporate voice notification? - ANSWERSWhen the
voice message is completely contained within the 1.5 second pause of the emergency
evacuation signal.
When the voice message is first preceded by a minimum of 8 cycles of the emergency
evacuation signal
When the voice message interrupts the emergency evacuation signal for no longer than
10 seconds, and is followed by 2 cycles of the emergency evacuation signal.

Whose responsibility is it to inform a technician of occupants with hearing disabilities? -
ANSWERSThe hearing impaired party

In what 6 places must detectors be installed to meet the requirements? - ANSWERS1.
In all sleeping and guest rooms
2. Outside of all sleeping rooms, within 21ft of the door
3. On every level, including basements
4. On every level of a residential board and care occupancy, including basements
5. In the living areas of a guest suite
6. In the living areas of a residential board and care occupancy

All points on a ceiling shall have a smoke alarm within a distance of _________ travel
distance or shall have the equivalent of ___________ smoke alarm per _________
meter squared - ANSWERS• 9.1m (30ft)
• One
• 46.5m2 (500ft2)

, In what 4 ways are smoke and heat alarms permitted to be powered? - ANSWERS1.
Commercial light and power supply capable of operating the device for at least 24 hours
in normal condition and 4 minutes of alarm
2. A noncommercial AC source with secondary power source capable of operating the
device for at least 7 days in the normal condition and 4 minutes of alarm.
3. A non rechargeable, non replaceable primary battery capable of operating the device
for at least 10 years and 4 minutes of alarm, followed by 7 days of trouble.
4. If battery primary power is permitted, requirements must meet 11.6.6 and 11.6.7
5. A spring wound mechanism with visible indication to show sufficient operating power
is available

In what 5 ways are household smoke and heat alarms permitted to be powered? -
ANSWERS1. Two independent power sources. Primary shall be commercial light and
power, secondary is a rechargeable battery.
2. Secondary source must be capable of operating the device for at least 24 hours and
4 minutes of alarm.
3. Secondary power source must be supervised, causing audible and visible trouble
signals upon removal or low battery condition.
4. Rechargeable batteries used for secondary power must be automatically recharged,
be recharged within 48 hours and provide a distinctive audible trouble signal before the
battery is incapable of powering the device.
5. Low power wireless systems must be powered by batteries that comply with 6.17

What must be visible on all AC power primary sources? - ANSWERSA 'power on'
indicator. The AC primary power must be supplied by a dedicated branch circuit or the
unswitched portion of a branch circuit used for power and lighting

Electrical systems not designed to be installed by an electrician shall be powered by a
source not in excess of how many volts? - ANSWERS30

All plug-in installations shall have a... - ANSWERSRestraining means (Transformer
screw)

AC primary power must be supplied by a dedicated branch circuit or... - ANSWERSThe
unswitched portion of a branch circuit used for power and lighting

What does GFCI stand for? - ANSWERSGround Fault Circuit Interrupter

What does AFCI stand for? - ANSWERSArc Fault Circuit Interrupter

Operation of a switch or GFCI shall not cause loss of what? - ANSWERSPrimary power

Smoke alarms powered by AFCI shall have...? - ANSWERSa source of secondary
power

Document information

Uploaded on
September 23, 2026
Number of pages
8
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$11.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
4
Followers
0
Items
1562
Last sold
2 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions