• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 3 out of 18 pages
Exam (elaborations)

NCLE Exam Questions with all Correct & 100% Verified Answers |Actual Complete Update |Already Graded A+ (Just Released)

Document preview thumbnail
Preview 3 out of 18 pages

NCLE Exam Questions with all Correct & 100% Verified Answers |Actual Complete Update |Already Graded A+ (Just Released)

Content preview

NCLE Exam Questions with all Correct & 100% Verified
Answers |Actual Complete Update |Already Graded A+
(Just Released)

DK/L Stands for: a. oxygen permeability, b. thermal conduction, c. oxygen transmissibility, d.
wettability ✔Correct Answer-C. Oxygen Transmissibility

A prism ballast, trunctated lens is on a left eye. The cylinder axis is 90 degrees. Prism base is
noted to rotate 15 ddegrees nasally. What cylinder axis shoud be ordered to compensate for the
rotation?
a. 95, b. 105, c. 110, d. 75, e. 80 ✔Correct Answer-B. 105

Small superficial linear stains are characteristic of?
a. foreign particles under the lens, b. poor insertion, c. exposure, d. unblemded peripheral
curves, e. flat lens corneal relationship ✔Correct Answer-A. Foreign particles under the lens

A patient has the following prescription: OD -4.50 -2.00 x 010 "k" 44.25@10/46.25@100
A trial lens of -2.00 -1.75 x 020 is placed on the eye. Using a -1.25 OR and the base pivots 10
degrees nasal, which lens should be ordered?
a. -3.25 -1.75 x 010, b. -3.25 -1.75 x 180, c. -3.25 -1.75 x 020, d. -3.25 -1.75 x 030 ✔Correct
Answer-B. -3.25 -1.75 x 180

Diffuse corneal stippling observed during a routine 6 month follow up visit is most likely due to:
a. microcystic edema, b. posterior surface deposits, c. warped lens, d. gross edema, e. incorrect
power ✔Correct Answer-B. Posterior surface deposits

Arc staining is observed during a routine follow up visit is most likely due to:
a. microcyst edema, b. posterior surface deposits, c. improper recentering technique, d. gross
edema, e. incorrect power ✔Correct Answer-C. Improper recentering technique

A flourescein pattern which shows a touch apperance in the horizontal meridian and a brighter
green in the vertical meridian indicates that the patient has:
a. against the rule astigmatism, b. residual astigmatism, c. with the rule astigmatism, d. oblique
astigmatism ✔Correct Answer-C. With the rule astigmatism

The advantage of fluorocarbon materials include:
a. wettability, b. deposit resistance, c. oxygen transmissibility, d. the use of larger lens
diameters, e. all of the above ✔Correct Answer-E. All the above

If a patient has reduced acuity and a gas permeable lens is found to flex on the eye, which lens
modifications are available to the fitter?

,a. larger diameter, b. steeper base curve, c. flatten base curve, d. thicker lens, e. c and d
✔Correct Answer-E. C and D

When modifying RGP lenses:
a. a fast spindle is necessary, b. an ammonia-based polishing compound should be used, c. the
polishing compound should be frequently applied, d. modifications should be avoided
✔Correct Answer-C. The polishing compound should be frequently applied

A fluorescesin pattern that shows a bright green in the center and bearing at the periphery
would indicate:
a. WTR pattern, b. Flat pattern, c. ATR pattern, d. Steep pattern ✔Correct Answer-D. Steep
pattern

The Burton Lamp is used to:
a. measure HVID, b. check for inflammation, c. steralize soft lenses, d. observe fluorescein
patterns, e. none of the above ✔Correct Answer-D. Observe fluorescein patterns

The most common problem with extended wear lenses is:
a. tight lens syndrome, b. dry eyes, c. lens coating, d. poor vision, e. none of these ✔Correct
Answer-C. Lens coating

Disposable contact lenses are approaved by the FDA for ________ of continous wear.
a. one week, b. two weeks, c. 1 month, d. 3 months, e. B and C ✔Correct Answer-E. B and C

The deposit most often seen on extended wearer lenses are:
a. protein, b. lipids, c. calcium, d. jelly bumps ✔Correct Answer-A. Protein

Following the Dyer Nomogram, which of the following would not be realistic K reading/lens
diameter relationship?
a. K: 43.00/44.00/lens diameter 8.5,
b. K: 48.00/49.00/lens diameter 7.8,
c. K: 40.00/41.00/lens diameter 9.3,
d. K: 40.00/41.00/lens diameter 8.3 ✔Correct Answer-D. K: 40.00/41.00/lens diameter 8.3

Given the following information: K's 45.00/44.00 @ 090 Rx -3.00 + 1.00 x 180
Which of the following set of specifications would most simulate an intrapalebral RGP fitting?
B.C. Rx Dia
a. 44.50 -2.50 8.5
b. 43.50 -1.50 8.5
c. 43.50 -1.50 9.5
d. 44.50 -2.50 9.5 ✔Correct Answer-A. 44.50 -2.50 8.5

RGP lenses should soak for a minimum of ________ hours for disinfection to take place.
a. 6 hrs, b. 4 hrs, c. overnight, d. no soaking is needed ✔Correct Answer-B. 4 hrs

, Given the following information: K's 42.00@180/43.00@90, Rx -2.00 -.75 x 180
Which of the following set of lens specifications would most simulate a lid attachment RGP
fitting:
B.C. Rx Dia
a. 43.00 -2.50 9.5
b. 41.50 -1.50 9.5
c. 42.50 -2.50 8.5
d. 43.00 -3.00 8.2 ✔Correct Answer-B. 41.50 -1.50 9.5

Which of the following polishing compounds should not be used with gas permeable lenses?
a. sil 02 care b. Silvo c. Alox PG d. XPal ✔Correct Answer-B. Silvo

When fitting superior limbal gas permeable lenses, the ideal lens-corneal relationship should
include the following except:
a. apical clearance
b. moderate edge lift
c. mild apical bearing
d. upper edge of the lens should be located at or near the superior limbus ✔Correct Answer-
A. Apical clearance

A patient fit .50 D flatter than K with contact lens power of -2.00 would most likely have a
spherical component of________ in their spectacle Rx, when in minus cylinder form. (use sam
or fap)
a. -.50, b. -2.50, c. -1.50, d. none of the above ✔Correct Answer-B. -2.50

In the Dyer nomogram, the primary curve is the:
a. steepest K, b. flattest K, c. median K, d. horizontal K ✔Correct Answer-B. Flattest K

Under slit lamp evaluation with fluorescein, corneal areas that appear dark and do not hold
stain during blinking are most likely:
a. dry spots, b. punctuates, c. infiltrates, d. abrasions ✔Correct Answer-A. Dry spots

When fitting one eye for distance and one eye for near, the distance correction is usually placed
in the:
a. dominant eye, d. non dominant eye c. more minus eye, d. less minus eye ✔Correct Answer-
A. Dominant eye

A nearsighted person will feel lack of accommodation from presbyopia:
a. earlier with contacts, b. earlier with spectacles, c. simultaneously with contact lenses and
spectacles, d. not at all with contacts ✔Correct Answer-A. Earlier with contacts

A farsighted person will feel lack of accommodation from presbyopia:

Document information

Uploaded on
September 20, 2026
Number of pages
18
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$18.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Studyclub
3.6
(14)
Sold
70
Followers
1
Items
13610
Last sold
1 week ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions