This RTE 1401 Exam 2 2026/2027 study resource contains 100+ questions, definitions and correct answers covering essential radiographic physics and imaging concepts. Across 27 pages, the document reviews x-ray production, radiation attenuation, digital and computed radiography, exposure factors, image quality, mAs and kVp, SID and OID, the inverse square law, grids, beam limitation, x-ray tube construction, focal spots, anode and cathode principles, radiation interactions, CR/DR detector technology and fluoroscopic image intensification. The cover page identifies the resource specifically as RTE 1401 Exam 2 for the 2026/2027 academic period. The opening section introduces key radiographic imaging and digital-image terminology, including attenuation, automatic rescaling, brightness, density, distortion, exposure index, exposure latitude, latent images, grids and penetrating ability. It distinguishes direct detector technology using amorphous selenium (a-Se) from indirect detector technology using amorphous silicon (a-Si), while also reviewing film-screen radiography, fluoroscopy and digital/computerized imaging as major imaging classifications. The document provides extensive review of exposure factors and image quality. Topics include milliampere-seconds, milliamperage, exposure time, kilovolt peak, source-to-image distance, object-to-image distance, focal-spot size, patient factors and image-receptor characteristics. Students review the 15% rule, reciprocity law, inverse square law and exposure-maintenance formula, as well as the four primary image-quality factors of exposure/brightness, contrast, spatial resolution and distortion. Digital concepts include window level, window width, deviation index, exposure index, automatic rescaling, quantum mottle, dynamic range, pixels and matrices. Another major section covers radiation classification and x-ray production. The material distinguishes primary, scatter, absorbed and remnant radiation and explains radiolucent versus radiopaque materials. It identifies four requirements for producing x-rays: a vacuum, source of electrons, method of accelerating electrons and method of stopping electrons. Students also review beam quantity, beam quality, filtration, differential absorption, transmission and scatter control. Pages 10–20 provide detailed coverage of the x-ray tube, anode and cathode assemblies. Topics include the filament, focusing cup, thermionic cloud, space-charge effect, target, focal point, actual and effective focal spots, line-focus principle, stationary and rotating anodes, rotor, stator, induction motor, protective housing, tube window, leakage radiation and the anode heel effect. The resource explains that radiation intensity is greater on the cathode side during the heel effect and discusses tungsten, rhenium and molybdenum in relation to filament and anode construction. It also includes the heat-unit formula (kVp × mA × seconds × rectification factor) and rectification constants for single-phase, three-phase and high-frequency equipment. The x-ray interaction section distinguishes five interactions listed in the document: coherent, Compton, photoelectric absorption, pair production and photodisintegration. Students review their relative energy ranges and characteristics, including Compton scatter as an important source of occupational exposure and photoelectric absorption as a contributor to patient dose. The material also covers Bremsstrahlung and characteristic x-ray production, including electron interactions with the target and characteristic energy transitions. The final portion compares computed radiography, direct DR, indirect DR and film-screen imaging. CR is described using photostimulable storage phosphor and barium fluorohalide crystals, including the sequence from PSP plate through laser scanning, light emission, photomultiplier detection and analog-to-digital conversion. Direct DR is associated with amorphous selenium and conversion of x-rays to an electronic signal, whereas indirect DR uses a scintillator and amorphous silicon in an x-ray-to-light-to-electrical-signal process. The closing pages also review fluoroscopic image-intensifier components, including the input phosphor, photocathode, electrostatic focusing lenses, anode and output phosphor. Relevant Students: This resource is relevant to students enrolled in RTE 1401 or comparable introductory radiographic physics and imaging courses, particularly radiography and radiologic technology students preparing for Exam 2 during 2026/2027. It is especially useful for students reviewing exposure techniques, digital imaging, x-ray tube construction, radiation interactions, CR and DR technology, image quality, radiographic geometry and fluoroscopy. The uploaded document does not identify a specific college or university, so an institution has not been assigned without source support. Keywords: RTE 1401 Exam 2, RTE , RTE 1401 questions and answers, RTE 1401 radiographic physics, radiographic physics Exam 2, radiography exam questions, radiologic technology exam, x ray production, x ray tube, anode and cathode, rotating anode, anode heel effect, line focus principle, focal spot, mAs radiography, kVp radiography, 15 percent rule, inverse square law, SID and OID, radiographic image quality, spatial resolution, radiographic contrast, automatic rescaling, exposure index, deviation index, quantum mottle, digital radiography, computed radiography, direct DR, indirect DR, amorphous selenium, amorphous silicon, photostimulable phosphor, barium fluorohalide, radiation attenuation, scatter radiation, remnant radiation, Compton interaction, photoelectric absorption, coherent scattering, pair production, photodisintegration, Bremsstrahlung radiation, characteristic radiation, fluoroscopy, image intensifier, radiation physics study guide

Content preview

RTE 1401 Exam 2 2026/2027
Expert Verifed Ace the Test



Attenuation - ANSWER ✔✔reduction in intensity as the beam passes

through matter


Automatic Rescaling - ANSWER ✔✔process by which images are

produced with uniform brightness and contrast regardless of the amount

of exposure


Brightness - ANSWER ✔✔function of a display monitor; changes

image lightness/darkness (density)


Density - ANSWER ✔✔DARKNESS


Direct Detector technology - ANSWER ✔✔uses amorphous selenium

as the active detector material

,Distortion - ANSWER ✔✔misrepresentation of the true size or shape

of an object

(magnification and true distortion are two types)


Exposure Index (EI) - ANSWER ✔✔Numeric representation of the

total x-ray exposure to the receptor (S-value)


Exposure Latitude - ANSWER ✔✔Range of exposures that can be

used and still result in the capture of a diagnostic quality image


Grid - ANSWER ✔✔device consisting of thin lead strips cleans up

scattor


Indirect Detector technology - ANSWER ✔✔2-step process that uses

amorphous silicon to covert x-ray energy to light and then to electrons


Latent Image - ANSWER ✔✔invisible image created after exposure

but before processing


Penetrating Ability - ANSWER ✔✔ability of an x-ray beam to pass

through an object; controlled by the kilovolt peak of the beam


Primary Radiation - ANSWER ✔✔X-ray beam after it leaves the x-ray

tube and before it reaches the object

, Three major classifications of diagnostic radiographic imaging -

ANSWER ✔✔film/screen radiography


fluoroscopic imaging

digital or computerize imaging


Four requirements to produce an x-ray - ANSWER ✔✔vacuum


source of electrons

method to accelerate electrons

method to stop the electrons


Scatter radiation - ANSWER ✔✔non-diagnostic radiation photons that

interact with the body's matter in such a way that the resulting photon

continues its travel in a different direction. (may or may not actually

reach image receptor)


photographic factor - ANSWER ✔✔density- kVp (color)


contrast- mAs


geometric factors - ANSWER ✔✔recorded detail (magnification)


- SID

-OID

distortion (depth perseption

COPYRIGHT©NINJANERD 2026/2027. YEAR PUBLISHED 2026. COMPANY REGISTRATION NUMBER: 619652435. TERMS OF USE. PRIVACY
STATEMENT. ALL RIGHTS RESERVED
3

Document information

Uploaded on
September 16, 2026
Number of pages
27
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$21.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
NinjaNerd
3.4
(79)
Sold
436
Followers
6
Items
15969
Last sold
3 days ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions