Prior to taking a pulmonary artery -the transducer is properly leveled and zeroed
wedge pressure (PCWP) reading, the
RT ensure that:
The fiberoptic bronchoscope is -flexibility
usually preferred device during
bronchoscopy b/c its:
The capnograph tracing above was -check the exhalation valve
obtained from a mechanically
ventilated pt. On the basis of this
tracing, the RT should:
,A RT is performing nasotracheal -use a longer suction catheter
suctioning. During the procedure, the
therapist occludes the catheter's
thumb port; there is no vacuum. The
therapist could do all of the following
EXCEPT
The primary hazard of an -the ot may gag or fight the device
oropharyngeal airway device is:
While manually ventilating a pt with a -the FiO2 will most likely be less than 1.0
bag-valve resuscitator during
cardiopulmonary resuscitation (CPR),
the RT notices that the oxygen
reservoir is missing. The therapist
should conclude that:
A pt with a tracheostomy tube is -a heated large reservoir air-entrainment jet
producing moderate amounts of nebulizer
thick, tenacious sputum. The best
device for this pt would be:
Which of the following humidity -heat moisture exchanger
devices is the most economical
choice for use in an intubated,
mechanically ventilated pt who only
needs short-term ventilation?
The RT noticed that the CPAP -tighten all connections
pressure indicated on the low
pressure monitor is consistently less
than the preset CPAP of an infant's
nasal CPAP system. Which of the
following should the therapist do
FIRST to correct this problem?
, While the RT is checking the oxygen -tighten all connections
setup of a pt on a 2L/min nasal
cannula, the pt complains of not
being able to detect any oxygen flow
from the cannula. Which of the
following actions would be
appropriate?
Which of the following will alter the 4 Increasing the flow setting-NO Occluding the air-
oxygen concentration of an air- entrainment ports-YES Altering the size of the jet
entrainment mask? 1 Increasing the orifice-YES
flow setting-YES Occluding the air-
entrainment ports-YES Altering the
size of the jet orifice-YES 2 Increasing
the flow setting-NO Occluding the
air-entrainment ports-YES Altering
the size of the jet orifice-NO 3
Increasing the flow setting-YES
Occluding the air-entrainment ports-
NO Altering the size of the jet orifice-
YES
While assessing a pt who is receiving -reposition the catheter
oxygen via transtracheal catheter, the
ot complains of a persistent,
nonproductive cough and tracheal
irritation. The appropriate action at
this time would be what?
and Verified Answers | 100% Correct | Grade A+
Play your way to mastery with fun games
Match Blocks Charms NEW
Terms in this set (158)
Prior to taking a pulmonary artery -the transducer is properly leveled and zeroed
wedge pressure (PCWP) reading, the
RT ensure that:
The fiberoptic bronchoscope is -flexibility
usually preferred device during
bronchoscopy b/c its:
The capnograph tracing above was -check the exhalation valve
obtained from a mechanically
ventilated pt. On the basis of this
tracing, the RT should:
,A RT is performing nasotracheal -use a longer suction catheter
suctioning. During the procedure, the
therapist occludes the catheter's
thumb port; there is no vacuum. The
therapist could do all of the following
EXCEPT
The primary hazard of an -the ot may gag or fight the device
oropharyngeal airway device is:
While manually ventilating a pt with a -the FiO2 will most likely be less than 1.0
bag-valve resuscitator during
cardiopulmonary resuscitation (CPR),
the RT notices that the oxygen
reservoir is missing. The therapist
should conclude that:
A pt with a tracheostomy tube is -a heated large reservoir air-entrainment jet
producing moderate amounts of nebulizer
thick, tenacious sputum. The best
device for this pt would be:
Which of the following humidity -heat moisture exchanger
devices is the most economical
choice for use in an intubated,
mechanically ventilated pt who only
needs short-term ventilation?
The RT noticed that the CPAP -tighten all connections
pressure indicated on the low
pressure monitor is consistently less
than the preset CPAP of an infant's
nasal CPAP system. Which of the
following should the therapist do
FIRST to correct this problem?
, While the RT is checking the oxygen -tighten all connections
setup of a pt on a 2L/min nasal
cannula, the pt complains of not
being able to detect any oxygen flow
from the cannula. Which of the
following actions would be
appropriate?
Which of the following will alter the 4 Increasing the flow setting-NO Occluding the air-
oxygen concentration of an air- entrainment ports-YES Altering the size of the jet
entrainment mask? 1 Increasing the orifice-YES
flow setting-YES Occluding the air-
entrainment ports-YES Altering the
size of the jet orifice-YES 2 Increasing
the flow setting-NO Occluding the
air-entrainment ports-YES Altering
the size of the jet orifice-NO 3
Increasing the flow setting-YES
Occluding the air-entrainment ports-
NO Altering the size of the jet orifice-
YES
While assessing a pt who is receiving -reposition the catheter
oxygen via transtracheal catheter, the
ot complains of a persistent,
nonproductive cough and tracheal
irritation. The appropriate action at
this time would be what?