SECTION I — NFPA 780 / LIGHTNING PROTECTION SYSTEMS
Questions 1–168


1. What is the primary purpose of a lightning protection system?
A. To prevent all lightning from striking a structure
B. To provide a controlled path for lightning current to ground
C. To eliminate electrical service interruptions
D. To increase the electrical resistance of a building
Correct Answer: B. To provide a controlled path for lightning current to
ground
Rationale: A lightning protection system provides intentional paths for
lightning current so the energy can be conducted safely toward ground
while reducing the likelihood of dangerous arcing and damage. It does
not prevent lightning strikes.


2. Which standard is the principal reference for lightning protection
system installation?
A. NFPA 780
B. NFPA 70E

,C. NFPA 101
D. NFPA 13
Correct Answer: A. NFPA 780
Rationale: NFPA 780 is the principal standard addressing installation
requirements for lightning protection systems and related components.


3. Which component is commonly installed to intercept a lightning
strike?
A. Ground-fault circuit interrupter
B. Air terminal
C. Disconnect switch
D. Transformer
Correct Answer: B. Air terminal
Rationale: An air terminal, commonly called a lightning rod, is a strike-
termination component intended to provide a preferred point for
lightning attachment.


4. What is the primary function of a lightning protection down
conductor?
A. To interrupt lightning current
B. To store lightning energy
C. To conduct lightning current toward the grounding system
D. To increase building voltage

,Correct Answer: C. To conduct lightning current toward the grounding
system
Rationale: Down conductors connect the roof-level lightning protection
components to the grounding electrode system and provide a
controlled current path.


5. What is the purpose of a grounding electrode in a lightning
protection system?
A. To isolate the structure from earth
B. To provide a connection between the lightning protection system and
earth
C. To increase roof resistance
D. To protect only telephone equipment
Correct Answer: B. To provide a connection between the lightning
protection system and earth
Rationale: Grounding electrodes provide the intentional interface
between the lightning protection conductors and the earth.


6. Why are multiple grounding connections often used in a lightning
protection system?
A. To create more controlled current paths and reduce impedance
B. To eliminate all electrical current
C. To increase the voltage of the lightning strike
D. To disconnect the building service

, Correct Answer: A. To create more controlled current paths and
reduce impedance
Rationale: Multiple paths can distribute lightning current and help
reduce impedance and potential differences throughout the system.


7. What does bonding accomplish in lightning protection?
A. It increases potential differences
B. It connects conductive parts to help keep them at similar potential
C. It eliminates the grounding system
D. It prevents all electrical faults
Correct Answer: B. It connects conductive parts to help keep them at
similar potential
Rationale: Bonding reduces differences in electrical potential between
conductive objects, helping reduce the possibility of sideflash.


8. What is a sideflash?
A. A lightning strike that occurs only underground
B. An arc between conductive objects caused by a potential difference
C. A normal branch-circuit fault
D. A type of circuit breaker
Correct Answer: B. An arc between conductive objects caused by a
potential difference

Document information

Uploaded on
September 15, 2026
Number of pages
131
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$19.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
CreativeWrites
3.6
(24)
Sold
113
Followers
3
Items
8668
Last sold
19 hours ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions