• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 4 out of 54 pages
Exam (elaborations)

Aci Written Exam Set Two

Document preview thumbnail
Preview 4 out of 54 pages

ACI WRITTEN EXAM SET TWO

Content preview

ACI WRITTEN EXAM SET TWO

QUESTION SET TWO

◉ A container used for the temperature test shall be large enough to
provide at least _____ inch(es) or 3 x NMS of the coarse aggregate as
concrete cover in all directions around the sensing portion of the
temperature measuring device.


A. 1-1/2
B. 3
C. 2
D. 1. Answer: B. 3


◉ A temperature measuring device shall have a capability of
measuring the temperature of freshly mixed concrete in the range of


A. 60 to 80 F
B. 30 to 120 F
C. 0 to 120 F
D. 30 to 80 F. Answer: B. 30 to 120 F

,◉ The temperature measuring device shall have a capability of
measuring the temperature of freshly mixed concrete to _____
degree(s) F


A. ± 1
B. ± 0.5
C. ± 2
D. ± 1.5. Answer: A. ± 1


◉ A composite sample of concrete is required even if the only
purpose for obtaining the sample is to determine temperature.


A. True
B. False. Answer: B. False


◉ Each Temperature Measuring Device used for determining
concrete temperature shall be verified _____ or whenever there is a
question of accuracy


A. once every six months
B. when initial received
C. annually
D. prior to each use. Answer: C. annually

,◉ The temperature of freshly mixed concrete can be measured in


A. transportation equipment
B. forms
C. all of the above
D. an adequate sized container.. Answer: C. all of the above


◉ Submerge the sensing portion of the temperature measuring
device a minimum of _____ inch(es) into the concrete


A. 1
B. 2
C. 3
D. 1-1/2. Answer: C. 3


◉ Concrete is gently pressed up against the temperature measuring
device to close the void created by inserting the TMD in the concrete
and so that ____ does not affect the temperature reading


A. the sun
B. the wind

, C. bleed water
D. ambient (outside) air temperature. Answer: D. ambient (outside)
air temperature


◉ Leave the temperature measuring device in the concrete for at
least _____ minute(s) before taking a reading


A. 3
B. 1
C. 4
D. 2. Answer: D. 2


◉ Assuming the coarse aggregate size is less than 3 inches, read the
temperature of the concrete within _____ minutes after inserting the
TMD


A. 4
B. 5
C. 2
D. 3. Answer: B. 5


◉ The temperature of freshly mixed concrete is read and recorded to
the nearest _____ degree(s) F.

Document information

Uploaded on
September 14, 2026
Number of pages
54
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$17.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
0
Followers
0
Items
834
Last sold
-



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions