EA Exam Questions & Answers (Grade
A+)
Apply the procedures regarding the modelling of domestic hot
water systems -
correct answer ✅HOT2000 User Guide
7.15.1 to 7.15.3, Appendix F
Efficiency Rating type:
select energy factor or uniform energy factor, if unknown, select
energy factor
If the Energy Factor radio button was selected, then select User
specified to enter the assessed Energy Factor. Alternatively, select
Standby to enter the efficiency by Standby Heat Loss, Thermal
Efficiency and Input Capacity. Data must be entered into all three of
these fields to define the efficiency by standby heat loss unless the
Energy Source is Electricity. In that case, the Thermal Efficiency is
automatically set to 98%. If the efficiency is unknown, use the
HOT2000 default.
For heat pump water heaters only integrated heat pump water
heaters located inside building envelope can be modelled in H2K
Do not use Tankless heat pump or Heat pump for modelling
,EA Exam Questions & Answers (Grade
A+)
integrated heat pump water heater HPWH energy factor 0.9
HP COP= HPWH EF/0.9
Desuperheater: electric storage type water heater
Explain the elements of the Guide to the Label. -
correct answer ✅Technical Procedures
Appendix F and G
-EnerGuide Rating : assessed using standard operation conditions.
Measured in GJ per year. EnerGuide Rating= Annual energy
consumption (-) On-site renewable energy contributions
- House Address
- Data collected: the date the evaluation was completed
- File number
- Evaluated by
,EA Exam Questions & Answers (Grade
A+)
- EnerGuide Rating scale
- Rated Annual energy consumption
- Energy Sources
- On-site renewable energy contributions
- Breakdown of rated annual energy consumption
- Rated energy intensity: Rated annual energy consumption divided
by heated floor area. It allows you to compare the annual energy
use of homes of different
sizes on a "per square metre" basis.
- Rated GHG emissions
- Significant Energy uses not included in rating
- Quality Assured by
Identify the information that must be collected for different types
of ventilation systems -
correct answer ✅Technical Procedures
3.5.11
ventilation systems are defined as either a mechanical whole-house
ventilation systems or as supplemental components.
, EA Exam Questions & Answers (Grade
A+)
whole-house ventilation system circulates air throughout the entire
house
Ventilation equipment that operates independent of the whole-
house system is considered to be a supplemental component.
Supplemental components are localized systems, such as kitchen
and bathroom fans.
heat or energy recovery ventilator (HRV/ERV):
-manufacturer name
-model number
-supply and exhaust flow rate
-fan power (W) at 0 °C (32 °F)
-fan power (W) at -25 °C (-13 °F)
-sensible recovery efficiency (SRE) at 0 °C (32 °F)
-sensible recovery efficiency (SRE) at -25 °C (-13 °F)
bathroom fans:
-manufacturer name
A+)
Apply the procedures regarding the modelling of domestic hot
water systems -
correct answer ✅HOT2000 User Guide
7.15.1 to 7.15.3, Appendix F
Efficiency Rating type:
select energy factor or uniform energy factor, if unknown, select
energy factor
If the Energy Factor radio button was selected, then select User
specified to enter the assessed Energy Factor. Alternatively, select
Standby to enter the efficiency by Standby Heat Loss, Thermal
Efficiency and Input Capacity. Data must be entered into all three of
these fields to define the efficiency by standby heat loss unless the
Energy Source is Electricity. In that case, the Thermal Efficiency is
automatically set to 98%. If the efficiency is unknown, use the
HOT2000 default.
For heat pump water heaters only integrated heat pump water
heaters located inside building envelope can be modelled in H2K
Do not use Tankless heat pump or Heat pump for modelling
,EA Exam Questions & Answers (Grade
A+)
integrated heat pump water heater HPWH energy factor 0.9
HP COP= HPWH EF/0.9
Desuperheater: electric storage type water heater
Explain the elements of the Guide to the Label. -
correct answer ✅Technical Procedures
Appendix F and G
-EnerGuide Rating : assessed using standard operation conditions.
Measured in GJ per year. EnerGuide Rating= Annual energy
consumption (-) On-site renewable energy contributions
- House Address
- Data collected: the date the evaluation was completed
- File number
- Evaluated by
,EA Exam Questions & Answers (Grade
A+)
- EnerGuide Rating scale
- Rated Annual energy consumption
- Energy Sources
- On-site renewable energy contributions
- Breakdown of rated annual energy consumption
- Rated energy intensity: Rated annual energy consumption divided
by heated floor area. It allows you to compare the annual energy
use of homes of different
sizes on a "per square metre" basis.
- Rated GHG emissions
- Significant Energy uses not included in rating
- Quality Assured by
Identify the information that must be collected for different types
of ventilation systems -
correct answer ✅Technical Procedures
3.5.11
ventilation systems are defined as either a mechanical whole-house
ventilation systems or as supplemental components.
, EA Exam Questions & Answers (Grade
A+)
whole-house ventilation system circulates air throughout the entire
house
Ventilation equipment that operates independent of the whole-
house system is considered to be a supplemental component.
Supplemental components are localized systems, such as kitchen
and bathroom fans.
heat or energy recovery ventilator (HRV/ERV):
-manufacturer name
-model number
-supply and exhaust flow rate
-fan power (W) at 0 °C (32 °F)
-fan power (W) at -25 °C (-13 °F)
-sensible recovery efficiency (SRE) at 0 °C (32 °F)
-sensible recovery efficiency (SRE) at -25 °C (-13 °F)
bathroom fans:
-manufacturer name