ET ASNT LEVEL I ACTUAL EXAM WITH CORRECT
ACTUAL QUESTIONS AND CORRECTLY WELL
DEFINED ANSWERS




Play your way to mastery with fun games


Match Blocks Charms NEW




Terms in this set (98)



I. A test specimen used as a basis for .C. reference standard
calibrating test cquipment or as a
comparison when evaluating test
results is referred to as a:
a. null-balancer
b. phase shifter .
C. reference standard
d. high pass filter

,In an eddy current testing situation, .d. all of the above
which of the following can provide
sources of noise?
a. instrumentation electronic circuits
b. nonspecific variations within the
test object
c. electrical interference
d. all of the above


3. The ratio of the response or b. signal-to-noise ratio
amplitude from signals of interest to
the response or amplitude of
indications that contain no useful
information for the test being
conducted is referred to as:
a. Poisson's ratio
b. signal-to-noise ratio
c. the conductivity-to-permeability
ratio
d. the reactance-to-resistance ratio




4. IACS is a recognized abbreviation d. International Annealed Copper Standard
for:
a. Induced Alternating Current
System
b. Inductively-Activated Comparison
System
c. Internal Applied Current System
d. International Annealed Copper
Standard

, Which of the following is not a basic c. liquid couplant
component of eddy current
equipment?
a. amplifier
b. coil
c. liquid couplant
d. detector


The process of comparing the a. calibration
reading or output of an instrument,
device, or dial with a standard to
determine the instrument's accuracy,
capacity, or graduations is referred to
as:
a. calibration
b. differentiation
c. integration
d. phase shifting


When'conducting an eddy current b. with the reference standard in one coil and an
test using a differential comparison acceptable test specimen in the other coil
coil arrangement that compares an
external reference standard with the
test specimen, the system should be
nulled or balanced:
a. with only the reference standard in
one coil
b. with the reference standard in one
coil and an acceptable test specimen
in the other coil
c. with the reference standard in one
coil and an unacceptable test
specimen in the other coil
d. with only the test specimen in one
coil

Document information

Uploaded on
September 13, 2026
Number of pages
27
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
Free
Download

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
113
Followers
0
Items
1298
Last sold
17 hours ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions