40 hour radiation safety..
Terms in this set (78)
The symbol R means roentgen
the acronym rad means radiation absorbed dose
the roentgen (R) exposure is measured in air
the symbol mR means milliroentgen
one roentgen or 1 R is equal to 1000 milliroentgen
the acronym rem stands for roentgen equivalent man
the initialism QF stands for quality factor
the quality factor for X-rays and gamma rays is 1
the quality factor for alpha (ray) particles is 20
activity of radioactive material is measured in curies
Becquerels and curies are units of measurement of decay rate
atoms that have excess energy and are unstable are radioactive
known as
elementary particle units with a negative electrical electrons
charge and a mass approximately equal to 1/1840 that
of a proton are
positively charged elementary particles with a mass protons
approximately equal to 1840 times that of an electron,
or 1 AMU, are known as
Page 1
, 40 hour radiation safety..
unchanged elementary particles with a mass nearly neutrons
equal that of a proton are called
the area known as the center of an atom is called the nucleus
any byproduct material that is encased in a capsule sealed source
designed to prevent leakage or escape of the
byproducts material is
a tube through which the radioactive source travels S tube
when inside a radiographic exposure device is a
survey meters must be calibrated at intervals not to six months and/or after instrument servicing except for batter changes
exceed:
a survey meter must be capable of measuring a range 2 to 1000 mR/h (0.02 to 10 mSv/h)
of
becquerels and curies are units of measurement of activity
an analog survey meter must be calibrated on each 33% and 66% on the scale's potential
scale at two points approximately
the process that results in the removal of orbital ionization
electrons from atoms resulting in the formation of ion
pairs is
the fact that gasses bombarded by ionizing radiation detection equipment
become conductors of electrical current make them
useful in
a dosimeter must be capable of reading a range of 0-200 mR (0-2mSv)
pocket ion chambers must be capable of reading 200 mR (2mSv)
an exposure rate is measured by survey meter
what dosimeters (dosimetric devices) are last affected TLDs
by moisture
full deflection of a survey meter while on batter check meter may or may not be working properly
means
dosimeters must be calibrated at intervals not to annually
exceed
Page 2
Terms in this set (78)
The symbol R means roentgen
the acronym rad means radiation absorbed dose
the roentgen (R) exposure is measured in air
the symbol mR means milliroentgen
one roentgen or 1 R is equal to 1000 milliroentgen
the acronym rem stands for roentgen equivalent man
the initialism QF stands for quality factor
the quality factor for X-rays and gamma rays is 1
the quality factor for alpha (ray) particles is 20
activity of radioactive material is measured in curies
Becquerels and curies are units of measurement of decay rate
atoms that have excess energy and are unstable are radioactive
known as
elementary particle units with a negative electrical electrons
charge and a mass approximately equal to 1/1840 that
of a proton are
positively charged elementary particles with a mass protons
approximately equal to 1840 times that of an electron,
or 1 AMU, are known as
Page 1
, 40 hour radiation safety..
unchanged elementary particles with a mass nearly neutrons
equal that of a proton are called
the area known as the center of an atom is called the nucleus
any byproduct material that is encased in a capsule sealed source
designed to prevent leakage or escape of the
byproducts material is
a tube through which the radioactive source travels S tube
when inside a radiographic exposure device is a
survey meters must be calibrated at intervals not to six months and/or after instrument servicing except for batter changes
exceed:
a survey meter must be capable of measuring a range 2 to 1000 mR/h (0.02 to 10 mSv/h)
of
becquerels and curies are units of measurement of activity
an analog survey meter must be calibrated on each 33% and 66% on the scale's potential
scale at two points approximately
the process that results in the removal of orbital ionization
electrons from atoms resulting in the formation of ion
pairs is
the fact that gasses bombarded by ionizing radiation detection equipment
become conductors of electrical current make them
useful in
a dosimeter must be capable of reading a range of 0-200 mR (0-2mSv)
pocket ion chambers must be capable of reading 200 mR (2mSv)
an exposure rate is measured by survey meter
what dosimeters (dosimetric devices) are last affected TLDs
by moisture
full deflection of a survey meter while on batter check meter may or may not be working properly
means
dosimeters must be calibrated at intervals not to annually
exceed