CSLB C10 Test 4 | 120 Questions and Answers (2025 / 2026) (Verified Answers) COMPLETE FREQUENTLY MOST TESTED QUESTIONS WITH COMPLETE SOLUTION /GET IT 100% ACCURATE!(Graded A+) In another case a motor has an over current protector but this time just the thermal protector causes the motor to trip off. What could be the cause? A Heat produced in the conductor. B Thermal element is too large. • California CSLB C10 Electrical Exam 09/11/2026 P 2 C Limited thermal elements. D The motor is too small. - Correct Answer :The Correct Answer Is A Thermal overload relays are used to protect the motor. They are sized usually between 115 percent to 125 percent. They respond to the heat generated by the current flowing through them. The height from the finish grade floor of conduit running to the outside of a gas station garage would be _____. A 6 in. B 12 in. C 18 in. D 20 in. - Correct Answer :The Correct Answer Is C The height from the finish grade floor of conduit running to the outside of a gas station garage would be 18 in. A hole is drilled in a non-supporting stud less than 1-1/4 in. from the end. What is a common practice? A It s non-bearing, so there s no problem. B Install a 1/16 in. steel plate over hole. C Replace stud.

Content preview

• California CSLB
C10 Electrical 09/11/2026



Exam

CSLB C10 Test 4 | 120 Questions and Answers
() (Verified Answers) COMPLETE
FREQUENTLY MOST TESTED QUESTIONS WITH
COMPLETE SOLUTION /GET IT 100%
ACCURATE!(Graded A+)




In another case a motor has an over current protector but this time just the thermal protector causes the motor
to trip off. What could be the cause?

A

Heat produced in the conductor.

B

Thermal element is too large.


P 1

, • California CSLB
C10 Electrical 09/11/2026



Exam
C

Limited thermal elements.

D

The motor is too small. - Correct Answer :The Correct Answer Is A

Thermal overload relays are used to protect the motor. They are sized usually between 115 percent to 125
percent. They respond to the heat generated by the current flowing through them.



The height from the finish grade floor of conduit running to the outside of a gas station garage would be _____.

A

6 in.

B

12 in.

C

18 in.

D

20 in. - Correct Answer :The Correct Answer Is C

The height from the finish grade floor of conduit running to the outside of a gas station garage would be 18 in.



A hole is drilled in a non-supporting stud less than 1-1/4 in. from the end. What is a common practice?

A

It s non-bearing, so there s no problem.

B

Install a 1/16 in. steel plate over hole.

C

Replace stud.

D



P 2

, • California CSLB
C10 Electrical 09/11/2026



Exam
Notify the building inspector. - Correct Answer :The Correct Answer Is B



What instrument is used to check the power of a circuit?

A

An ammeter

B

A wattmeter

C

A voltmeter

D

An omeger - Correct Answer :The Correct Answer Is B

A wattmeter is preferred, however, you could calculate the power with a voltage reading from a voltmeter and a
current reading from an ammeter and multiply the two values.



The biggest problem with the use of aluminum wiring is _____.

A

splicing

B

cost

C

mil size

D

heat - Correct Answer :The Correct Answer Is D

The biggest problem with the use of aluminum wiring is heat.



You have had to replace the ballast in a fluorescent fixture. What should be done with the bad ballast?



P 3

, • California CSLB
C10 Electrical 09/11/2026



Exam
A

Check for PCB s.

B

Throw it in trash.

C

Place it in recycling.

D

Leave it for owner. - Correct Answer :The Correct Answer Is A

Dispose of it properly.



You are required to add a duplex receptacle to a box that is connected with a brranch circuit. How are the
ground conductors connected?

A

Pigtailed together and hung in box.

B

They are kept seperated.

C

Pigtailed together and attached to the receptacle.

D

None of the above. - Correct Answer :The Correct Answer Is C



A motor is running in the wrong direction. What can be done about it?

A

For three phase motors, reverse any two leads.

B

You can usually switch phase A and C.



P 4

Document information

Uploaded on
September 13, 2026
Number of pages
471
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$24.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
JoyceWWales
3.9
(29)
Sold
141
Followers
18
Items
3159
Last sold
3 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions