Preview 4 out of 315 pages

CSLB C10 Test 1 | 120 Questions and Answers (2025 / 2026) (Verified Answers) COMPLETE FREQUENTLY MOST TESTED QUESTIONS WITH COMPLETE SOLUTION /GET IT 100% ACCURATE!(Graded A+) The total equivalent bend in rigid conduit between pull points (outlet to outlet, fitting to fitting, or outlet to fitting) shall not exceed _____. A-3 quarter bends (270 degrees) B-4 quarter bends (360 degrees) C-5 quarter bends (450 degrees) D-6 quarter bends (540 degrees) - Correct Answer :The Correct Answer Is B Two 45 degrees bends plus three 90 degrees bends equals the maximum of 360 degrees total. • California CSLB C10 Electrical Exam 09/11/2026 P 2 When a branch circuit feeds both noncontiguous and continuous loads, the circuit must be sized to accommodate 100 percent of the noncontiguous load plus what percent of the continuous load? A-110 percent B-115 percent C-120 percent D-125 percent - Correct Answer :The Correct Answer Is D The rating of branch circuits serving continuous loads shall be not less than the noncontiguous load plus 125 percent of the continuous load. The branch-circuit load for a single 12-kilowatt (12 kW) electric range in a dwelling is _____. A-8 kW B-9 kW C-10 kW D-11 kW - Correct Answer :The Correct Answer Is A NEC Table 220.4(C) permits an electric range with a kW nameplate rating not exceeding 12 kW to be rated at 8kW when sizing branch circuits and feeders. A 20-ampere laundry circuit is always required in each _____. A-industrial wash room B-commercial utility room C-dwelling unit D-motel unit - Correct Answer :The Correct Answer Is C In dwelling units, at least one 20 amp branch circuit shall be installed for the laundry. How many receptacles are required in a residential hallway 12 feet in length?

Content preview

• California CSLB
C10 Electrical 09/11/2026



Exam

CSLB C10 Test 1 | 120 Questions and Answers
() (Verified Answers) COMPLETE
FREQUENTLY MOST TESTED QUESTIONS WITH
COMPLETE SOLUTION /GET IT 100%
ACCURATE!(Graded A+)




The total equivalent bend in rigid conduit between pull points (outlet to outlet, fitting to fitting, or outlet to
fitting) shall not exceed _____.

A-3 quarter bends (270 degrees)

B-4 quarter bends (360 degrees)

C-5 quarter bends (450 degrees)

D-6 quarter bends (540 degrees) - Correct Answer :The Correct Answer Is B

Two 45 degrees bends plus three 90 degrees bends equals the maximum of 360 degrees total.


P 1

, • California CSLB
C10 Electrical 09/11/2026



Exam

When a branch circuit feeds both noncontiguous and continuous loads, the circuit must be sized to
accommodate 100 percent of the noncontiguous load plus what percent of the continuous load?

A-110 percent

B-115 percent

C-120 percent

D-125 percent - Correct Answer :The Correct Answer Is D

The rating of branch circuits serving continuous loads shall be not less than the noncontiguous load plus 125
percent of the continuous load.



The branch-circuit load for a single 12-kilowatt (12 kW) electric range in a dwelling is _____.

A-8 kW

B-9 kW

C-10 kW

D-11 kW - Correct Answer :The Correct Answer Is A

NEC Table 220.4(C) permits an electric range with a kW nameplate rating not exceeding 12 kW to be rated at
8kW when sizing branch circuits and feeders.



A 20-ampere laundry circuit is always required in each _____.

A-industrial wash room

B-commercial utility room

C-dwelling unit

D-motel unit - Correct Answer :The Correct Answer Is C

In dwelling units, at least one 20 amp branch circuit shall be installed for the laundry.



How many receptacles are required in a residential hallway 12 feet in length?

A-1


P 2

, • California CSLB
C10 Electrical 09/11/2026



Exam
B-2

C-3

D-4 - Correct Answer :The Correct Answer Is A

NEC Section 210.52(H) requires at least one receptacle outlet in hallways 10 feet or more in length.



How many receptacle outlets are required in a residential garage?

A-4

B-3

C-2

D-1 - Correct Answer :The Correct Answer Is D

At least one receptacle outlet to be installed in each basement and in each attached garage, or in each detached
garage with electric power.



A 125-volt single phase, 15- or 20-ampere receptacle must be installed in _____ for the servicing of heating, air
conditioning and refrigeration equipment?

A-all apartment buildings

B-one- and two-family dwellings

C-commercial buildings

D-all locations - Correct Answer :The Correct Answer Is D

Receptacle outlets are required for equipment in any location the equipment is present. The NEC has removed
the exception for equipment on rooftops of one- and two-family dwellings.



How many lighting outlets must be installed at or near heating, air-conditioning, and refrigeration equipment in
attics or crawl spaces?

A-1

B-2

C-3



P 3

, • California CSLB
C10 Electrical 09/11/2026



Exam
D-4 - Correct Answer :The Correct Answer Is A

NEC Sections 210.70(A) and(C) require at least one switched lighting outlet in these spaces.



Feeders containing a common neutral are permitted to supply how many sets of 3-wire feeders?

A-1 or 2

B-5 or 6

C-3 or 4

D-2 or 3 - Correct Answer :The Correct Answer Is D

NEC Section 215.4(A) permits two or three sets of 3-wire feeders.



Feeders containing a common neutral are permitted to supply how many sets of 4-wire feeders?

A-2

B-3

C-4

D-5 - Correct Answer :The Correct Answer Is A

NEC Section 215.4(A) permits two sets of 4-wire feeders.



Feeders containing a common neutral are permitted to supply how many sets of 5-wire feeders?

A-1

B-2

C-3

D-4 - Correct Answer :The Correct Answer Is B

NEC Section 215.4(A) permits a common neutral to supply two sets of 5-wire feeders.



On a 4-wire, delta-connected secondary where the midpoint of one phase is grounded to supply lighting and
similar loads, what color must the conductor having the highest voltage be?



P 4

Document information

Uploaded on
September 13, 2026
Number of pages
315
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$24.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
JoyceWWales
3.9
(29)
Sold
141
Followers
18
Items
3159
Last sold
3 days ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions