CHST REVIEW EXAM WITH CORRECT ACTUAL
QUESTIONS AND CORRECTLY WELL DEFINED
ANSWERS LATEST 2025 ALREADY GRADED A+
Play your way to mastery with fun games
Match Blocks Charms NEW
Terms in this set (130)
employer responsibilities regarding 1. delegate implementation to 'competent person'
use of GFCI 2. 120V which operate at 15 to 20 amps, not
permanent, equipe with GFCI
3. applies to all cord sets not part of permanent
building struction
4.maintain written description of th eprovisions.
OSHA specification which apply to -no more than three tucks ina wire rope
wire rope used in construction -wire ropes used for hoisting or lowering be
rigging continuous length of rope without knot or splice
except for eye splices at the end
-eyes in wire rope slings or bridles not to be
compromised of wire rope clips or knots
-no more than 10% visible broken wires
, concerns of 'system safety analysis' analytical stufy of the interacting components of a
process.
'gas chromatography' -measure environmental toxins in the air
-separates and isolates components of a mixture of
gases
-combine with mass spectometer
employee benefits of JSA -supervisor meets with employees
-train in productive and safe operations
-supervisor communicates and apply safety
techniques
Footcandles for Gen Constr. concrete 5
placement, excavation, loading
platforms, refueling, field
maintenance areas
Footcandles for Indoor warehouses, 5
corridors, hallways, and exit ways
Footcandles for tunnels, shafts and 5
general underground work areas
Footcandles for construction plant 10
and shops, mechanical and electrical
equipment rooms, carpenter shops,
rigging lofts and active storerooms
QUESTIONS AND CORRECTLY WELL DEFINED
ANSWERS LATEST 2025 ALREADY GRADED A+
Play your way to mastery with fun games
Match Blocks Charms NEW
Terms in this set (130)
employer responsibilities regarding 1. delegate implementation to 'competent person'
use of GFCI 2. 120V which operate at 15 to 20 amps, not
permanent, equipe with GFCI
3. applies to all cord sets not part of permanent
building struction
4.maintain written description of th eprovisions.
OSHA specification which apply to -no more than three tucks ina wire rope
wire rope used in construction -wire ropes used for hoisting or lowering be
rigging continuous length of rope without knot or splice
except for eye splices at the end
-eyes in wire rope slings or bridles not to be
compromised of wire rope clips or knots
-no more than 10% visible broken wires
, concerns of 'system safety analysis' analytical stufy of the interacting components of a
process.
'gas chromatography' -measure environmental toxins in the air
-separates and isolates components of a mixture of
gases
-combine with mass spectometer
employee benefits of JSA -supervisor meets with employees
-train in productive and safe operations
-supervisor communicates and apply safety
techniques
Footcandles for Gen Constr. concrete 5
placement, excavation, loading
platforms, refueling, field
maintenance areas
Footcandles for Indoor warehouses, 5
corridors, hallways, and exit ways
Footcandles for tunnels, shafts and 5
general underground work areas
Footcandles for construction plant 10
and shops, mechanical and electrical
equipment rooms, carpenter shops,
rigging lofts and active storerooms