NYC MASTER ELECTRICIAN EXAM
Study online at https://quizlet.com/_6x5xx9

1. Type ____ is multiconductor cable identified for use as Type USE cable
underground service entrance cable.

2. Knife switch rated for more than 1200 Amps at Can be used only as iso-
250Volts or less lating switch, shall not be
opened under load

3. Track lighting with outlets in a bathroom is not al- Track lighting has recepta-
lowed because ? cle

4. Where internal combustion engines are used as the 6 hours
prime motor, an on site fuel supply shall be provided
with an on premise fuel supply sufficient for not less
than ____ hours full demand operation of the system

5. Fixed in place X-ray equipment properly supplied by a 30 Amps
branch circuit rated at not over ____ amperes shall be
permitted to be supplied through a suitable attach-
ment plug cap and hard service cable cord.

6. Where skin effect exist the ferromagnetic envelope Both ends
shall be bonded at ____.

7. GFCI protection at a carnival is not required for equip- Locking
ment at circuit if the receptacle is of the ____type.

8. The maximum voltage drop from service point to the 4%
last over-current device in a dwelling unit?

9. Which of the following statements best describe the Accessible non current
grounding requirement for central vacuum outlet carrying metal parts are
required to be connected




, NYC MASTER ELECTRICIAN EXAM
Study online at https://quizlet.com/_6x5xx9

to an equipment ground-
ing conductor.

10. In healthcare facilities, patient bed receptacles locat- Are permitted
ed in general care areas shall be supplied by at least
two branch circuits, which ____permitted to originate
from two separate transfer switches on the emer-
gency system

11. Patient care areas of healthcare facilities ____ ar- Do not include
eas such as business offices, corridors, lounges ,day
rooms, or similar areas

12. The patient care area is any portion of the healthcare Examined or treated
facility where patients are intended to be ____or ____.

13. Each general care area patient bed location in a Single or two
healthcare facility must be provided with four ____ or
____ duplex receptacles

14. A hospital is a building or portion thereof used for Four
medical, psychiatric,obstetrical , or surgical, care on a
24 hour basis of ____ or more patients

15. Where installed to reduce electrical noise for elec- Listed fitting
tronic equipment, electrical continuity of the metal
raceways shall not be required and metal raceway can
terminate a (an) ____ nonmetallic fitting or spacer on
electronic equipment

16. Feeder and branch circuit conductors within ____ inch- 3 inches
es of a Ballast shall have an insulation temperature
rating not lower than 90°C (194°F) unless supplying a



, NYC MASTER ELECTRICIAN EXAM
Study online at https://quizlet.com/_6x5xx9

luminaiere marked as suitable for a different insula-
tion temperature

17. Manufactured wiring systems constructed with type 6 ft
MC cable shall be supported and secured at intervals
not exceeding ____ ft.

18. Where a main bonding jumper or a system bonding Green finish
jumper is a screw only the screw shall be identified
with a ____ that shall be visible with the screw installed

19. Plug fuses a 15 amperes and lower rating shall be Hexagon
identified by a ____ configuration of the window, cap,
or other prominent part to distinguish them from fus-
es of higher ampere rating

20. The load for household electric clothes dryer's in a 5000 watts
dwelling unit(s) shall be either ____ watts (volt-am-
peres) or the nameplate rating, which ever is larger,
for each dryer served ?

21. Service conductors installed as unjacketed multicon- 3 ft (36 inches)
ductor cable shall have a minimum clearance of ____
windows that are designed to be opened, doors,
porches, stairs fire escape or similar locations.

22. —— Cartridge fuses of the renewable type shall be Class H
permitted to be used only for replacement in existing
installation is where there is no evidence of over-fus-
ing or tampering.

23. 3" inches




, NYC MASTER ELECTRICIAN EXAM
Study online at https://quizlet.com/_6x5xx9

Branch circuit conductors within ____inches of the bal-
last shall have an insulation temperature rating not
lower it 90°C 194°F

24. The minimum radius of a field bend on trade size 1 8
"1/4 RMC is ____.

25. In a dwelling unit which appliance is allowed to have Combination range
a 24"inch cord with Attachment ground plug ? hood/microwave oven

26. Type 3 Surge Protective devices can be installed on Included in the manufac-
the load side of a branch circuit overcurrent device tures instructions
up to the equipment served.if ____ the type 3 SPD
connection must be a minimum 30'ft of conductor a
distance from the service or separately derived sys-
tem disconnect

27. Which flexible cable is Allowed to be used for electric EVJ
vehicle charging station 300 Volts ?

28. Type ____ fuse adapters shall be designed so that once Type S fuse
inserted in a fuse holder that cannot be removed

29. Service drops Installed over roof shall have a vertical 8'ft
clearance of ____ above the roof surface, and unless a
lesser distance is permitted by and exceptions

30. Class 2 and Class 3 circuits shall not be placed in any Separated by barrier
enclosure, raceway, cable, or similar fittings with con-
ductors of Class 1 or electric light or power conduc-
tors, unless ____.

31. 3 duplex (6 single)

Document information

Uploaded on
September 11, 2026
Number of pages
63
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$10.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
0
Followers
0
Items
28
Last sold
-



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions