1. Which New Mexico state agency regulates low-voltage contractor licensing, including the ES-7
classification?
A) New Mexico Public Regulation Commission
B) New Mexico Construction Industries Division (CID)
C) New Mexico Department of Workforce Solutions
D) New Mexico Energy, Minerals and Natural Resources Department
Correct Answer: B) New Mexico Construction Industries Division (CID)
Rationale: The New Mexico Construction Industries Division (CID), operating under the Regulation
and Licensing Department, regulates all contractor licensing in the state, including low-voltage
electrical specialties such as ES-3 and ES-7 classifications. The CID administers examinations, issues
licenses, and enforces compliance with state regulations .
2. What is the ES-7 license classification in New Mexico?
A) Sound and Alarm Systems Contractor
B) General Electrical Contractor
C) Telephone Systems Contractor
D) Fire Sprinkler Contractor
Correct Answer: C) Telephone Systems Contractor
Rationale: The ES-7 classification specifically covers Telephone Systems contractors in New Mexico.
This license authorizes the installation, service, and repair of telephone systems, data cabling, and
related communications infrastructure. The ES-3 classification separately covers sound and alarm
systems .
3. Which edition of the National Electrical Code (NEC) has New Mexico adopted for electrical
installations effective March 28, 2023?
A) 2017 NEC
B) 2020 NEC
C) 2023 NEC
D) 2014 NEC
,Correct Answer: B) 2020 NEC
Rationale: New Mexico adopted the 2020 National Electrical Code (NFPA 70) effective March 28,
2023. All low-voltage contractors, including ES-7 license holders, must comply with this edition when
performing installations. The exam is administered based on the 2020 NEC starting December 15,
2024 .
4. Which NEC article primarily governs telephone and data communication circuits?
A) Article 725
B) Article 760
C) Article 800
D) Article 300
Correct Answer: C) Article 800
Rationale: NEC Article 800 specifically covers communications circuits, including telephone, data, and
similar low-voltage systems. It provides comprehensive installation, grounding, bonding, and
protection requirements for communications systems. Article 725 covers Class 2 and 3 remote-control
circuits, while Article 760 addresses fire alarm systems .
5. The demarcation point (DEMARC) is best defined as:
A) The location of the PBX system within the building
B) The point where customer wiring connects to the service provider's network
C) The grounding electrode connection location
D) The first telephone outlet in the building
Correct Answer: B) The point where customer wiring connects to the service provider's network
Rationale: The demarcation point is the physical and legal boundary where the telecommunications
service provider's responsibility ends and the customer's premises wiring begins. This point, often
housed in a Network Interface Device (NID), is critical for troubleshooting and determining liability for
service issues .
6. Which cable rating is required when telephone cabling is installed in an environmental air
plenum space?
A) CM (Communications General Purpose)
B) CMR (Communications Riser)
C) CMP (Communications Plenum)
D) CMX (Communications Residential)
Correct Answer: C) CMP (Communications Plenum)
Rationale: NEC Article 800.113(A) requires Type CMP (communications plenum cable) in ducts,
plenums, and other environmental air-handling spaces. CMP-rated cable has specialized flame-
retardant and low-smoke properties to prevent toxic smoke from circulating through HVAC systems in
a fire .
, 7. According to NEC 800.100(A)(4), what is the minimum size copper conductor required for the
bonding conductor or grounding electrode conductor for communications systems?
A) 14 AWG
B) 10 AWG
C) 8 AWG
D) 6 AWG
Correct Answer: D) 6 AWG
Rationale: NEC Article 800.100(A)(4) requires the bonding conductor or grounding electrode
conductor for communications systems to be not smaller than 6 AWG copper. This provides a low-
impedance path for fault currents, ensuring proper protection and safety .
8. Which standard governs labeling, administration, and documentation of telecommunications
cabling infrastructure?
A) NEC Article 800
B) NFPA 72
C) TIA/EIA-606
D) OSHA 1910
Correct Answer: C) TIA/EIA-606
Rationale: TIA/EIA-606 establishes standards for labeling, administration, and documentation of
telecommunications infrastructure. This standard supports proper maintenance, troubleshooting, and
compliance by ensuring consistent identification of cables, pathways, and spaces throughout the
cabling system .
9. What type of test verifies correct conductor termination, continuity, and polarity in telephone
cabling?
A) Certification test
B) Megger test
C) Wire map test
D) Load test
Correct Answer: C) Wire map test
Rationale: Wire map tests verify continuity, correct pinout configuration, opens, shorts, and polarity
to ensure proper cable installation. This test confirms that each conductor is terminated at the correct
pin position on both ends of the cable, which is essential for reliable telephone and data
transmission .
10. Which system allows multiple internal telephone extensions to share outside telephone lines
efficiently?