S13 STANDPIPE ACTUAL TEST UPDATED QUESTIONS AND VERIFIED RESPONSES Gallons per minute (GPM) - ANSWER -typically used to measure fluid flow rate (such as water) or pump capacity. Measurement of water flow rate for a pump or a fire standpipe or sprinkler system. Hose Connection - ANSWER -a combination of equipment provided for connection of a hose to the standpipe system that includes a hose valve with a threaded outlet. Attack Hose - ANSWER -Hose designed to be used by trained fire fighters and fire brigade members to combat fires beyond the incipient stage. Booster Hose - ANSWER -A non-collapsible hose used under positive pressure having an elastomeric or thermoplastic tube, a braided or spiraled reinforcement, and an outer protective cover. Covered Hose - ANSWER -A hose with a jacket covered and lined with a continuous synthetic rubber or plastic. The cover is usually thicker than a coating. Fire Hose - ANSWER -A flexible conduit used to convey water. Hose Valve - ANSWER -The valve to an individual hose connection Occupant Use Hose - ANSWER -Fire hose designed to be used by the building's occupants to fight incipient fires prior to the arrival of trained fire fighters or fire brigade members. Unlined Hose - ANSWER -A hose consisting of only a woven jacket that is usually of linen yarns and is of such quality that the yarn swells when wet, tending to seal the hose. Hose Size - ANSWER -An expression of the internal diameter of the hose. Hose Station - ANSWER -a combination of a hose rack, hose nozzle, hose, and hose connection. In Service - ANSWER -The status of hose stored in a hose house, on a rack or reel, or on a fire apparatus that is available and ready for immediate use at an incident. This doesn't include hose in the storage where it is not readily available to be put into service at an incident. In Storage - ANSWER -A hose that is not readily available for use because it is not at the scene of an incident and not loaded on a vehicle that can transport it to the scene. In Use - ANSWER -Hose being used during fire suppression or during training. Impairment Coordinator - ANSWER -The person responsible for ensuring that proper safety precautions are taken when a fire protection system is placed out of service. The building owner shall assign an impairment coordinator to comply with the requirements of this section. In the absence of a specific designee, the owner shall be considered the impairment coordinator. Labeled - ANSWER -Equipment or materials to which has been attached a label, symbol or other identifying mark or an organization that is acceptable to the authority having jurisdiction and concerned with product evaluation, that maintains periodic inspection of production of labeled equipment or materials , and by whose labeling the manufacturer indicates compliance with appropriate standard or performance in a specified manner. Listed Device - ANSWER -A fire protection component that has been tested to perform under parameters specified for its use by a nationally recognized testing agency. Underwriter's Laboratory (UL) and Factory Mutual (FM) are the two most common once. Manual Standpipe - ANSWER -Standpipe system that relies exclusively on the fire department connection to supply the system demand. Master Pressure Reducing Valve - ANSWER -A pressure reducing valve installed to regulate pressures in an entire fire protection system and/or standpipe system zone. Main Drain - ANSWER -The primary drain connection located on the system riser and also utilized as a flow test connection for the automatic sprinkler system. Nozzles - ANSWER -A device for use in applications requiring special water discharge patterns, directional spray, or other unusual discharge characteristics. Occupant-Use Hose - ANSWER -Fire Hose designed to be used by the building's occupants to fight incipient fires prior to the arrival of trained fire fighters or fire brigade members. Out of service system - ANSWER -A fire protection system that is not fully functional; or whose operation is impaired or is otherwise not in good working order. Personal Supervision - ANSWER -Supervision by the holder of a department certificate who is required to be personally present on the premises, or other proximate location acceptable to the department, while the duties for which the certificate is required is being performed. Pounds per square inch (PSI) - ANSWER -a unit of pressure measuring force per unit area. Pressure Control Valve - ANSWER -A pilot operated pressure reducing valve that may be used with a fire or booster pump designed for the purpose of preventing the incoming water supply pressure from dropping below a set pressure. Pressure Control Valve - ANSWER -A pilot-operated pressure-reducing valve designed for the purpose of reducing the downstream water pressure to a specific value under both flowing (residual) and non flowing (static) conditions. Pressure-Reducing Valve - ANSWER -A valve designed for the purpose of reducing the downstream water pressure under both flowing (residual) and non flowing (static) conditions. Pressure Regulating Device - ANSWER -A device designed for the purpose of reducing, regulating controlling, or restricting water pressure. Example includes pressure reducing valve, pressure control valves, and pressure-restricting devices. Pressure Restricting Device - ANSWER -A valve or device designed for the purpose of reducing of reducing the downstream water pressure under flowing (residual) conditions only.

Content preview

S13 STANDPIPE ACTUAL TEST UPDATED
QUESTIONS AND VERIFIED RESPONSES

Gallons per minute (GPM) - ANSWER -typically used to measure fluid flow rate
(such as water) or pump capacity. Measurement of water flow rate for a pump or a
fire standpipe or sprinkler system.

Hose Connection - ANSWER -a combination of equipment provided for
connection of a hose to the standpipe system that includes a hose valve with a
threaded outlet.

Attack Hose - ANSWER -Hose designed to be used by trained fire fighters and
fire brigade members to combat fires beyond the incipient stage.

Booster Hose - ANSWER -A non-collapsible hose used under positive pressure
having an elastomeric or thermoplastic tube, a braided or spiraled reinforcement,
and an outer protective cover.

Covered Hose - ANSWER -A hose with a jacket covered and lined with a
continuous synthetic rubber or plastic. The cover is usually thicker than a coating.

Fire Hose - ANSWER -A flexible conduit used to convey water.

Hose Valve - ANSWER -The valve to an individual hose connection

Occupant Use Hose - ANSWER -Fire hose designed to be used by the building's
occupants to fight incipient fires prior to the arrival of trained fire fighters or fire
brigade members.

Unlined Hose - ANSWER -A hose consisting of only a woven jacket that is
usually of linen yarns and is of such quality that the yarn swells when wet, tending
to seal the hose.

Hose Size - ANSWER -An expression of the internal diameter of the hose.

Hose Station - ANSWER -a combination of a hose rack, hose nozzle, hose, and
hose connection.

, In Service - ANSWER -The status of hose stored in a hose house, on a rack or
reel, or on a fire apparatus that is available and ready for immediate use at an
incident. This doesn't include hose in the storage where it is not readily available to
be put into service at an incident.

In Storage - ANSWER -A hose that is not readily available for use because it is
not at the scene of an incident and not loaded on a vehicle that can transport it to
the scene.

In Use - ANSWER -Hose being used during fire suppression or during training.

Impairment Coordinator - ANSWER -The person responsible for ensuring that
proper safety precautions are taken when a fire protection system is placed out of
service. The building owner shall assign an impairment coordinator to comply with
the requirements of this section. In the absence of a specific designee, the owner
shall be considered the impairment coordinator.

Labeled - ANSWER -Equipment or materials to which has been attached a label,
symbol or other identifying mark or an organization that is acceptable to the
authority having jurisdiction and concerned with product evaluation, that maintains
periodic inspection of production of labeled equipment or materials , and by whose
labeling the manufacturer indicates compliance with appropriate standard or
performance in a specified manner.

Listed Device - ANSWER -A fire protection component that has been tested to
perform under parameters specified for its use by a nationally recognized testing
agency. Underwriter's Laboratory (UL) and Factory Mutual (FM) are the two most
common once.

Manual Standpipe - ANSWER -Standpipe system that relies exclusively on the
fire department connection to supply the system demand.

Master Pressure Reducing Valve - ANSWER -A pressure reducing valve installed
to regulate pressures in an entire fire protection system and/or standpipe system
zone.

Main Drain - ANSWER -The primary drain connection located on the system
riser and also utilized as a flow test connection for the automatic sprinkler system.

Document information

Uploaded on
September 6, 2026
Number of pages
10
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$13.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TheExamMaestro
3.6
(18)
Sold
155
Followers
5
Items
3771
Last sold
5 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions