1. What is the purpose of the glass envelope in an X-ray tube? - Correct
Answer: It allows air to be evacuated for efficient electron flow, provides
insulation from electrical shock, and dissipates heat to the surrounding
insulation oil.
2. What is the function of the tube housing in an X-ray tube? - Correct
Answer: It is lined with lead to provide additional shielding against leakage
radiation.
3. What material is the anode of an X-ray tube made from, and what are its
components? - Correct Answer: The anode is made of tungsten,
embedded in a molybdenum and graphite base.
4. What is the difference between a stationary anode and a rotating anode? -
Correct Answer: A stationary anode is simple and used in dental
applications with lower heat capacity and exposure, while a rotating anode
is complex, used in general X-ray, and has higher heat capacity and
exposure.
,5. What is the role of the focusing cup in an X-ray tube? - Correct Answer:
It has a negative charge to keep electrons focused in a single stream
towards the anode target.
6. What is the purpose of the filament in an X-ray tube? - Correct Answer:
It provides a source of electrons through thermionic emission and boils off
excess electrons.
7. What does the thin exiting window in an X-ray tube do? - Correct
Answer: It allows the photon beam to pass out of the X-ray tube to the
patient.
8. What is the function of the stator in an X-ray tube? - Correct Answer: It
is an electric motor that turns the rotor at high speed.
9. What is the rotor made of, and what is its function in an X-ray tube? -
Correct Answer: The rotor is made of copper and is rigidly connected to the
target, causing it to rotate rapidly during X-ray production.
10.What are bearings in the context of an X-ray tube? - Correct Answer:
They are low friction spheres that allow free rotation of the rotor.
11.What is the anode heel effect? - Correct Answer: It describes how the X-
ray beam has greater intensity on the cathode side, diminishing towards the
anode side due to the angle of the target.
,12.What factors affect the anode heel effect? - Correct Answer: The anode
heel effect is influenced by the angle of the target, with a higher anode
angle resulting in a decreased effect, and a decreased source-to-image
distance (SID) and increased field size resulting in an increased effect.
13.What is the line focus principle in an X-ray tube? - Correct Answer: It
describes the relationship between the actual spot on the anode and the
effective focal spot that extends from the anode.
14.What is the actual focal spot in an x-ray tube? - Correct Answer: The size
of the area on the anode target exposed to electrons from the tube current,
which is larger than the effective focal size.
15.How is the effective focal spot defined? - Correct Answer: It is measured
directly under the anode and exits the tube to interact with the patient.
16.What is off-focus radiation? - Correct Answer: Radiation produced from
rebounding electrons, originating outside the anode focal spot.
17.How is tube loading measured? - Correct Answer: By the amount of
heat produced during exposure, calculated as heat units = mAs x kVp x
generator factors.
18.What are the generator factors for different types of x-ray generators? -
Correct Answer: Single phase = 1, 3 phase = 1.35, High frequency = 1.4.
, 19.What does Ohm's law state? - Correct Answer: V = IR, I = V/R, R = V/I.
20.What are the characteristics of series circuits? - Correct Answer: It has
the same current (It = I1 = I2 = I3) and total resistance (Rt = R1 + R2 + R3),
with total voltage being the sum of individual voltages (Vt = V1 + V2 + V3).
21.What are the characteristics of parallel circuits? - Correct Answer: Total
current is the sum of individual currents (It = I1 + I2 + I3), total resistance is
calculated as 1/Rt = 1/R1 + 1/R2 + 1/R3, and total voltage is the same across
all branches (Vt = V1 = V2 = V3).
22.What is the primary/low voltage circuit in an x-ray machine? - Correct
Answer: It includes the main power supply, primary side of the step-up
transformer, AC current, and components like fuses, line voltage meter, and
autotransformer.
23.What is the role of the step-up transformer in an x-ray circuit? - Correct
Answer: It increases voltage from the primary circuit to kilovolts in the
secondary circuit.
What is the function of rectifiers in the x-ray circuit? - Correct Answer: They
convert AC current to DC current using solid-state semiconductor diodes.
What is the filament circuit in an x-ray tube? - Correct Answer: It contains the
cathode filaments and operates on AC current, regulating amperage for
thermionic emission.