S-12 Sprinkler Test & S-13 Standpipe
Test Questions & Answers 2026-2027 |
Sprinklers Segment 5
Document Overview
This document contains 398 verified questions with correct answers regarding sprinkler
and standpipe systems. It serves as a comprehensive resource for understanding critical
fire protection concepts. Ideal for study, review, and certification preparation, it ensures
users have direct access to accurate information needed to excel in their knowledge of fire
safety systems.
100% Accurate Questions and Answers 100% Guarantee Pass - Verified by Experts
Expert-Verified
Verified Answers · 398 Questions · September 2026
S-12 Sprinkler Test & S-13 Standpipe Test Questions & Answers 2026-2027 | Sprinklers Segment 5 - Practice Questions Page 0
,Topics Covered
Section 1: Fire Department Connections
Questions covering fire Department Connections concepts.
Section 2: Control Valves and Pumps
Questions covering control Valves and Pumps concepts.
Section 3: Fire Pump Operations
Questions covering fire Pump Operations concepts.
Section 4: Water Supply and Storage
Questions covering water Supply and Storage concepts.
Section 5: Sprinkler Systems Overview
Questions covering sprinkler Systems Overview concepts.
Section 6: Sprinkler Types and Applications
Questions covering sprinkler Types and Applications concepts.
Section 7: Hydraulic Calculations
Questions covering hydraulic Calculations concepts.
Section 8: Impairment and Deficiencies
Questions covering impairment and Deficiencies concepts.
Section 9: Pressure Management
Questions covering pressure Management concepts.
Section 10: Alarm and Supervisory Signals
Questions covering alarm and Supervisory Signals concepts.
Section 11: Testing and Maintenance
Questions covering testing and Maintenance concepts.
Section 12: Hose and Nozzle Specifications
Questions covering hose and Nozzle Specifications concepts.
Section 13: Standpipe Systems
Questions covering standpipe Systems concepts.
Section 14: Standpipe Testing Procedures
Questions covering standpipe Testing Procedures concepts.
Section 15: Standpipe Design and Installation and More
Questions covering standpipe Design and Installation and More concepts.
QUESTION 1 OF 398
fire department connection
Correct Answer: normally on exterior of building... FDNY can pump supplemental water into the sprinkler
system, standpipe, or other system furnishing water for fire extinguishment to supplement existing water
supplies.
S-12 Sprinkler Test & S-13 Standpipe Test Questions & Answers 2026-2027 | Sprinklers Segment 5 - Practice Questions Page 0
, QUESTION 2 OF 398
fire command center
Correct Answer: Designated room or area in a structure where the status of the fire detection, alarm, and
protection systems is displayed and the systems can be manually controlled.
QUESTION 3 OF 398
Spray Sprinkler
Correct Answer: A type of sprinkler listed for its capability to provide fire control for a wide range of fire
hazards. The most commonly used sprinkler since 1953.
QUESTION 4 OF 398
Pumper Connections for Fire Department Use
Correct Answer: Fire Department connections must always be accessible. Each connection shall be fitted
with a lower check valve. The lower check valve prevents the backflow of the private water supply into the
Fire Department connection. The figure below shows the main features of a Fire Department connection.
QUESTION 5 OF 398
Control valve
Correct Answer: A valve controlling flow to water base fire protection system. Control valve do not include
hose valves
QUESTION 6 OF 398
what is a fire hydrant?
Correct Answer: A valve connection on a water supply system having one or more outlets and that is used
to supply hose and fire department connections with water.
QUESTION 7 OF 398
Auxiliary water supply
Correct Answer: supplementary source of water for a standpipe and/or sprinkler system.
QUESTION 8 OF 398
Fire Department Connection
Correct Answer: A connection , normally on the exterior of the building, through which the fire
department can pump supplemental water into the sprinkler system, standpipe, or other system furnishing
water for fire extinguishment to
supplement existing water supplies. (Formerly know as Siamese connection.)
S-12 Sprinkler Test & S-13 Standpipe Test Questions & Answers 2026-2027 | Sprinklers Segment 5 - Practice Questions Page 0
, QUESTION 9 OF 398
A Covered Hose is
Correct Answer: A hose with a jacket covered and lined with a continuous synthetic rubber or plastic. The
cover is usually thicker than a coating.
QUESTION 10 OF 398
Out of service system
Correct Answer: A fire protection system that is not fully functional; or whose operation is impaired or is
otherwise not in good working order.
QUESTION 11 OF 398
Quick Opening Devices
Correct Answer: a device used to speed up the time it takes for water to reach sprinkler heads/standpipe
QUESTION 12 OF 398
Alarms and Supervisory Signal Devices
Correct Answer: A Supervisory signal means that a device is activated that would hinder an important
functionality of a fire alarm system.
QUESTION 13 OF 398
What are the two types of fire department connections?
Correct Answer: Freestanding & Wall mounted
QUESTION 14 OF 398
Nozzles must be able to flow at __ pressures for occupational use
Correct Answer: Low pressures
QUESTION 15 OF 398
How long do you conduct a hydro-static test on a dry standpipe system?
Correct Answer: 24 hours
QUESTION 16 OF 398
Which items are kept in a hose house?
Correct Answer: Hoses,nozzles and standpipe connections
QUESTION 17 OF 398
Where are gauges located on a wet pipe sprinkler system?
Correct Answer: On the water supply and the service side.