OHIO STATE FIRE MARSHAL - 2026/2027 ACADEMIC YEAR -
QUESTIONS AND ANSWERS COVERING FOUR CORE DOMAINS
150 QUESTIONS
TABLE OF CONTENTS
# TOPIC
1 Analyze and apply Ohio Revised Code and Ohio Administrative Code provisions governing fireworks
exhibitions
2 Evaluate and implement comprehensive safety measures, including site assessment, crowd control, and
handling procedures
3 Synthesize operational knowledge to manage complex exhibition scenarios, including equipment
selection and failure analysis
4 Develop and execute effective emergency response plans tailored to pyrotechnic incidents
5 Ohio Fireworks Exhibitor Comprehensive Examination
6 Ohio State Fire Marshal
7 2026
8 2027 Academic Year
9 Questions and Answers Covering Four Core Domains
10 Foundations of Ohio Fireworks Exhibitor Comprehensive Examination - Ohio State Fire Marshal
11 Applied Ohio Fireworks Exhibitor Comprehensive Examination - Ohio State Fire Marshal
12 Advanced Ohio Fireworks Exhibitor Comprehensive Examination - Ohio State Fire Marshal
13 Ohio Fireworks Exhibitor Comprehensive Examination - Ohio State Fire Marshal Review
ABSTRACT
Page 1
,This study document brings together 150 carefully worded exam questions drawn from Ohio
Fireworks Exhibitor Comprehensive Examination - Ohio State Fire Marshal - 2026/2027 Academic
Year - Questions and Answers Covering Four Core Domains, with the strongest emphasis placed
on Analyze and apply Ohio Revised Code and Ohio Administrative Code provisions governing
fireworks exhibitions, Evaluate and implement comprehensive safety measures, including site
assessment, crowd control, and handling procedures, Synthesize operational knowledge to
manage complex exhibition scenarios and including equipment selection and failure analysis.
Every item follows the wording style and level of reasoning you meet in the real paper, and each
one is paired with a clear rationale so the correct choice is never a guess. Work through the set at
your own pace, mark the questions that slow you down, then come back to them until the
reasoning feels automatic. Learners who revise this way walk into the exam room recognising the
pattern behind the questions instead of meeting them for the first time. Keep going - steady, honest
practice is what turns a difficult paper into a comfortable pass.
Q1 ANALYZE AND APPLY OHIO REVISED CODE AND OHIO ADMINISTRATIVE CODE
PROVISIONS GOVERNING FIREWORKS EXHIBITIONS
A licensed exhibitor is planning a display at a county fairgrounds. The site has a
permanent grandstand with a capacity of 5,000 and an adjacent open field. Under
Ohio Administrative Code 1301:4-6-02, which of the following is the MINIMUM
separation distance from the nearest spectator area to the fall-out zone for aerial
shells up to 8 inches in diameter?
A. 50 feet
B. 70 feet
C. 100 feet
D. 150 feet CORRECT
RATIONALE: OAC 1301:4-6-02 requires a minimum separation distance of 150 feet for aerial
shells up to 8 inches. Options A, B, and C are below the regulatory minimum and would not be
compliant.
Page 2
,Q2 ANALYZE AND APPLY OHIO REVISED CODE AND OHIO ADMINISTRATIVE CODE
PROVISIONS GOVERNING FIREWORKS EXHIBITIONS
During a pre-show inspection, an exhibitor finds that a batch of 3-inch shells has a
visible crack in the casing and loose lift charge. According to NFPA 1123 and Ohio
Fire Code, what is the REQUIRED action?
A. Repair the casing with tape and use the shell in the show.
B. Set aside the damaged shells and dispose of them in a approved manner after the show.
CORRECT
C. Use the shells at the end of the show to minimize risk if they fail.
D. Return the shells to the supplier for credit immediately.
RATIONALE: Damaged fireworks must be removed from service and disposed of according to
regulations. Option A is unsafe; C ignores the hazard; D is not required by code, though it may
be an option.
Q3 ANALYZE AND APPLY OHIO REVISED CODE AND OHIO ADMINISTRATIVE CODE
PROVISIONS GOVERNING FIREWORKS EXHIBITIONS
An exhibitor is setting up for an outdoor display and the weather forecast
indicates a thunderstorm with lightning within 10 miles. According to NFPA 1123,
what is the correct action regarding the setup and firing?
A. Proceed with the display but reduce the number of shells.
B. Delay the display until the storm passes and conditions are safe. CORRECT
C. Continue firing but use electronic ignition to reduce risk.
D. Move the firing site to a covered area and continue.
RATIONALE: NFPA 1123 requires that operations cease when lightning is within 10 miles.
Delaying is the only safe option. Other options ignore the risk of lightning strikes.
Page 3
, Q4 ANALYZE AND APPLY OHIO REVISED CODE AND OHIO ADMINISTRATIVE CODE
PROVISIONS GOVERNING FIREWORKS EXHIBITIONS
In Ohio, a licensed exhibitor may be exempt from certain local ordinances under
specific conditions. Which of the following scenarios correctly applies the Ohio
Revised Code exemption?
A. A display conducted by a licensed exhibitor for a private party on private property with owner
consent.
B. A display conducted by a licensed exhibitor for a charitable fundraiser on public property.
C. A display conducted by a licensed exhibitor for a city's Fourth of July celebration on public
property. CORRECT
D. A display conducted by a licensed exhibitor for a commercial event with paid admission.
RATIONALE: ORC 3743.55 exempts displays conducted by licensed exhibitors for public entities
from local ordinances. Private, charitable, and commercial events do not fall under this
exemption.
Q5 ANALYZE AND APPLY OHIO REVISED CODE AND OHIO ADMINISTRATIVE CODE
PROVISIONS GOVERNING FIREWORKS EXHIBITIONS
An exhibitor is using a digital firing system with wireless modules. According to
NFPA 1126, what is the MINIMUM safety protocol for wireless firing systems to
prevent accidental ignition?
A. Use a unique frequency for each show and encrypt the signal.
B. Ensure the system has a key switch and a separate arming button.
C. Disconnect the battery from the firing system until all personnel are clear. CORRECT
D. Use a radio frequency that is not used by other devices in the area.
RATIONALE: NFPA 1126 requires that the firing system be disabled (e.g., battery disconnected)
until the site is clear. Other options are good practices but not the primary safety protocol.
Page 4