SC LP Gas Reseller Exam: Practice Test
Study online at https://quizlet.com/_bqlxbf
1. A member of the LP Other than a Deputy State Fire Marshal of the Division of State Fire Marshal,
Gas Board who may be permitted to enter during reasonable business hours to inspect
your gas industry to assure the safety of the public?
2. An individual certified South Carolina's laws regarding the retail sale of propane to the public
as competent by the require that the seller have a license from the LP Gas Board and...?
Division of State Fire
Marshal
3. Not to exceed 6 According to the National Fire Protection Association Pamphlet (NFPA) #58,
months from the date what is the limit on a temporary installation?
of installation
4. 1.0 lbs. per 10,000 gal- The ratio of Ethyl Mercaptan per 10,000 gallons of LP Gas by test shall be
lons of LP-Gas how many lbs. per gallon?
5. U.S. Department of DOT containers shall be designed, fabricated, tested, and marked (or
Transportation stamped) in accordance with which organization?
6. 120,000 water gallons Containers for general use shall not have individual water capacities greater
than how many gallons?
7. 30,000 water gallons Service station containers shall not have individual capacities greater than
how many gallons?
8. Bathroom NFPA pamphlet #54 states that unvented space heaters are not to be
installed in which area?
9. NFPA #58 as adopted When LP-Gas and other compressed gases are to be stored in the same
by the LP Gas Board area, the containers shall be marked according to which regulatory agency?
10. Cast Iron What material may NOT be used under service conditions for container
appurtenances for LP Gas?
1/9
, SC LP Gas Reseller Exam: Practice Test
Study online at https://quizlet.com/_bqlxbf
11. 250 PSIG Container appurtenances shall have a rated working pressure of at least
what PSIG?
12. 12 years from man- All industrial trucks, including fork lift containers in use shall have the
ufacture date and pressure relief valve replaced at what interval?
every 10 years there-
after
13. 60 drill size opening Excess flow valves shall be designed to close automatically at the rated flow
of vapor or liquid specified by the manufacturer. Valves shall be designed
with a bypass, not to exceed what size drill opening?
14. To indicate the maxi- What is the purpose of a fixed liquid level gauge on containers to be filled
mum filling level by volume?
15. Container opening or Pressure gauges shall be installed in what part of a LP Gas System used in
to a valve or fitting a bulk plant?
which is attached di-
rectly to container
16. 350 PSIG Fittings used at pressures higher than container pressure on the discharge
of the liquid transfer pump shall be suitable for a working pressure of at
least how much PSIG?
17. 250 PSIG Fittings used with liquid LP Gas or with vapor LP Gas at operating pressures
over 125 PSIG shall have a working pressures of what PSIG?
18. 125 PSIG Fittings for use with vapor LP Gas at pressures not exceeding 125 PSIG shall
be suitable for a working pressure of what PSIG?
19. 1,750 PSIG Hose used for LP Gas liquid transfer shall have a bursting pressure of what
PSIG?
20.
2/9
Study online at https://quizlet.com/_bqlxbf
1. A member of the LP Other than a Deputy State Fire Marshal of the Division of State Fire Marshal,
Gas Board who may be permitted to enter during reasonable business hours to inspect
your gas industry to assure the safety of the public?
2. An individual certified South Carolina's laws regarding the retail sale of propane to the public
as competent by the require that the seller have a license from the LP Gas Board and...?
Division of State Fire
Marshal
3. Not to exceed 6 According to the National Fire Protection Association Pamphlet (NFPA) #58,
months from the date what is the limit on a temporary installation?
of installation
4. 1.0 lbs. per 10,000 gal- The ratio of Ethyl Mercaptan per 10,000 gallons of LP Gas by test shall be
lons of LP-Gas how many lbs. per gallon?
5. U.S. Department of DOT containers shall be designed, fabricated, tested, and marked (or
Transportation stamped) in accordance with which organization?
6. 120,000 water gallons Containers for general use shall not have individual water capacities greater
than how many gallons?
7. 30,000 water gallons Service station containers shall not have individual capacities greater than
how many gallons?
8. Bathroom NFPA pamphlet #54 states that unvented space heaters are not to be
installed in which area?
9. NFPA #58 as adopted When LP-Gas and other compressed gases are to be stored in the same
by the LP Gas Board area, the containers shall be marked according to which regulatory agency?
10. Cast Iron What material may NOT be used under service conditions for container
appurtenances for LP Gas?
1/9
, SC LP Gas Reseller Exam: Practice Test
Study online at https://quizlet.com/_bqlxbf
11. 250 PSIG Container appurtenances shall have a rated working pressure of at least
what PSIG?
12. 12 years from man- All industrial trucks, including fork lift containers in use shall have the
ufacture date and pressure relief valve replaced at what interval?
every 10 years there-
after
13. 60 drill size opening Excess flow valves shall be designed to close automatically at the rated flow
of vapor or liquid specified by the manufacturer. Valves shall be designed
with a bypass, not to exceed what size drill opening?
14. To indicate the maxi- What is the purpose of a fixed liquid level gauge on containers to be filled
mum filling level by volume?
15. Container opening or Pressure gauges shall be installed in what part of a LP Gas System used in
to a valve or fitting a bulk plant?
which is attached di-
rectly to container
16. 350 PSIG Fittings used at pressures higher than container pressure on the discharge
of the liquid transfer pump shall be suitable for a working pressure of at
least how much PSIG?
17. 250 PSIG Fittings used with liquid LP Gas or with vapor LP Gas at operating pressures
over 125 PSIG shall have a working pressures of what PSIG?
18. 125 PSIG Fittings for use with vapor LP Gas at pressures not exceeding 125 PSIG shall
be suitable for a working pressure of what PSIG?
19. 1,750 PSIG Hose used for LP Gas liquid transfer shall have a bursting pressure of what
PSIG?
20.
2/9