Question 1
According to NFPA 70E, what is the primary goal of
an Electrical Safety Program?
,A) Zero lost-time injuries
B) Full compliance with the National Electrical Code
C) Practical elimination of electrical hazards through
risk assessment and controls
D) Reduction of insurance premiums
Correct Answer: C) Practical elimination of
electrical hazards through risk assessment and
controls
*Rationale: * Article 110.1(A) of NFPA 70E explicitly
states that the goal of the Electrical Safety Program
is the practical elimination of electrical hazards by
means of risk assessment and appropriate control
measures. The focus is on hazard elimination rather
than merely achieving compliance or reducing costs.
Question 2
An electrical safety program audit identifies
inconsistent energized electrical work practices.
What action should a CESCP professional
recommend FIRST?
,A) Purchase additional arc-rated PPE for all
employees
B) Review and update the electrical safety program
based on identified deficiencies
C) Require employees to stop all electrical work
permanently
D) Increase the frequency of electrical equipment
inspections only
Correct Answer: B) Review and update the
electrical safety program based on identified
deficiencies
*Rationale: * The safety professional should first
address deficiencies within the electrical safety
program itself. A comprehensive program review
ensures procedures, responsibilities, training
requirements, and risk controls align with applicable
safety requirements. PPE and inspections are
important controls but do not replace correcting
program-level deficiencies.
, Question 3
How often must an Electrical Safety Program be
reviewed and updated according to NFPA 70E?
A) Annually
B) Every 2 years
C) Every 3 years
D) Only after an incident occurs
Correct Answer: C) Every 3 years
*Rationale: * NFPA 70E Article 110.1(H) requires
that the electrical safety program shall be reviewed
at intervals not to exceed 3 years. This ensures the
program remains current with changes in
operations, equipment, and regulatory
requirements.
Question 4
When must an Electrical Safety Program be
documented according to NFPA 70E?
A) Only for systems operating at more than 600 V
B) Only for contractors, not for host employers