(LATEST) || MOST RECENT EXAM 2026|2027 ACTUAL
COMPLETE REAL EXAM QUESTIONS AND CORRECT ANSWERS
(VERIFIED ANSWERS) ALREADY GRADED A+ | GUARANTEED
SUCCESS!! NEWEST
What type of window is hinged on one side only? -ANSWERS-Casement
An inspector is required to operate any _____ valves of the plumbing
system. -ANSWERS-Outdoor hose bib
A stud on a load bearing wall may be notched up to _____ percent. -
ANSWERS-25
Switches for a spa or hot tub shall be located at least _____ feet from
the inside walls of the spa or hot tub. -ANSWERS-5
_____ inches X ______ inches is the minimum dimension for a egress
window in a
sleeping room. -ANSWERS-20 - 24
_____ inches is the maximum distance that a window sill can be located
from the
,floor in a bedroom. -ANSWERS-44
The maximum length of a dryer vent is _____ feet. -ANSWERS-35
The minimum clearance of an electric service wire over a walkway is
_____ feet. -ANSWERS-10
Romex must be supported at least every ____ feet in an attic. -
ANSWERS-4 1/2
The minimum size for an attic access having a clear height over 30
inches is _____
X _____ . -ANSWERS-22 x 30 inches
Hallways of ____ feet or more in length shall have at least one
receptacle outlet. -ANSWERS-10
The minimum size (AWG) circuit conductor for a 20 amp circuit is ____
gauge
copper. -ANSWERS-12
The minimum height that a flue vent can terminate above the roof is
______. -ANSWERS-3
,The minimum clearance for an electrical wire over a swimming pool is
_____ feet. -ANSWERS-22
Woodwork or other combustibles should not be placed within _____
inches of a
fireplace opening. -ANSWERS-6
A minimum of two ____ amp rated branch circuits are to be provided to
serve
receptacles located in the kitchen, pantry, and breakfast area. -
ANSWERS-20
Range and dryer connections labeled for a gas appliance connection
may not
exceed _____ feet. -ANSWERS-6
The minimum hearth extension on the side of a fireplace with a 6
square foot
opening and a firebox depth of 24 inches is _____ inches. -ANSWERS-12
The maximum distance that mechanical equipment can be located from
an attic
access is ____ feet. -ANSWERS-20
, The minimum clearance for lighting over a swimming pool is _____
feet. -ANSWERS-12
Surface mounted fluorescent fixtures shall be installed on the wall
above the door
or on the ceiling, provided there is a minimum clearance of _____
inches between
the fixture and the nearest point of a storage space. -ANSWERS-6
12 gauge aluminum wires should be connected to a _____ amp
breaker. -ANSWERS-15
The minimum thickness for a solid garage door to a living area is ____
inches. -ANSWERS-1 3/8
You cannot take return air from a Kitchen or bathroom -ANSWERS-True
Romex must be stapled a maximum of _____ inches from the wall
outlet and then every
4.5 feet. -ANSWERS-12
The minimum stairway tread is _____ inches. -ANSWERS-10