• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 4 out of 202 pages
Exam (elaborations)

Wgu D486 Dfn1 Task 1 - Practice Question Bank 300 Multiple Choice Questions With Answers And Rationales Latest Update Of This Year .Assured Pass!!!

Document preview thumbnail
Preview 4 out of 202 pages

This comprehensive practice question bank contains 300 multiple-choice questions with detailed answers and rationales specifically designed for the WGU D486 DFN1 TASK 1 performance assessment. Covering the complete Fielder Medical Center (FMC) Security Assessment Report analysis, this resource walks you through all six security gaps identified by Pruhart Consulting, including lack of antivirus protection, inadequate endpoint protection, missing MFA implementation, PCI DSS compliance issues, insecure government agency access, and improper PII storage. The questions thoroughly cover NIST SP 800-53 control families (AC, IA, SC, SI, CP, AU, AT, MP, PE, PS, PT, PM, RA, IR, MA, CM, CA, PL, SA, and more), the Risk Management Framework (RMF) six-step process, HIPAA compliance requirements, FISMA mandates, and FMC-specific remediation strategies. Each question includes the correct answer and a comprehensive rationale to deepen your understanding of federal security compliance frameworks. Whether you're preparing for the WGU D486 assessment, studying for security certifications, or need to understand real-world security control implementation, this question bank provides the rigorous practice you need to succeed.

Content preview

WGU D486 DFN1 TASK 1 - PRACTICE QUESTION
BANK 300 MULTIPLE CHOICE QUESTIONS WITH
ANSWERS AND RATIONALES LATEST UPDATE OF THIS
YEAR .ASSURED PASS!!!




Section 1: FMC Security Gaps Overview (Questions 1-30)


Question 1
What was the overarching concern identified by Pruhart Consulting regarding
FMC's systems?


A) Lack of security policies
B) All FMC-connected systems are senescent (outdated)
C) Absence of MFA
D) Lack of antivirus protection


Answer: B) All FMC-connected systems are senescent (outdated)


Rationale: Pruhart identified that all FMC-connected systems are senescent and
require analysis, ranking, compliance improvements, and a maintenance plan. This
overarching concern affects all other security gaps identified in the assessment .

,---


Question 2
Which of the following is NOT a security gap identified in FMC's Security
Assessment Report?


A) Lack of antivirus and endpoint protection
B) Outdated systems design
C) Excessive security controls causing operational delays
D) Lack of MFA


Answer: C) Excessive security controls causing operational delays


Rationale: The SAR identified six specific security gaps, including lack of
antivirus/endpoint protection, outdated systems design, lack of MFA, inadequate
PCI DSS compliance, lack of secure government access, and insecure PII storage.
Excessive security controls was not identified as a gap .


---


Question 3
What was the first security gap identified by Pruhart Security Consulting?

,A) Lack of MFA
B) Workstations lack the necessary and correct antivirus protection
C) Inadequate endpoint protection
D) Lack of secure PII storage


Answer: B) Workstations lack the necessary and correct antivirus protection


Rationale: The first identified gap was that workstations connected to the network
switches lack the necessary and correct antivirus protection. This fundamental
security control gap leaves systems vulnerable to malware infections .


---


Question 4
FMC's planned POS system for medical equipment sales cannot meet compliance
requirements for which standard?


A) HIPAA
B) FISMA
C) PCI DSS
D) SOX


Answer: C) PCI DSS

, Rationale: The SAR identified that FMC's inability to meet PCI DSS compliance
requirements for the planned POS system is a significant gap. FMC must
implement secure networks, firewalls, remove vendor-supplied defaults, and
install antivirus solutions to address this gap .


---


Question 5
FMC is a federally-funded healthcare facility that must comply with which federal
requirements?


A) HIPAA only
B) FISMA requirements and mandates
C) SOX only
D) GLBA only


Answer: B) FISMA requirements and mandates


Rationale: As a federally-funded healthcare facility, FMC falls under Federal
Information Security Management Act (FISMA) requirements and mandates, in
addition to healthcare-specific regulations .


---


Question 6

Document information

Uploaded on
September 1, 2026
Number of pages
202
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$21.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
PassPioneer
2.0
(1)
Sold
3
Followers
0
Items
210
Last sold
3 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions