MEDICAL GAS 6010 TEST PAPER ANSWERS AND
QUESTIONS SET A+
✔✔A _ shutoff valve shall be provided in the main supply line when the source valve is
not accessible from within the building served? A) main B) supply C) service D) zone -
✔✔A) main

✔✔_ valves shall be installed to allow modification of lateral branch piping from a main
or riser without shutting down the entire main, riser, or facility? A) main B) riser C)
service D) zone - ✔✔C) service

✔✔Regardless of how many zone valve boxes are installed on a lateral branch off a
riser, only one _ valve shall be required for each branch? A) main B) riser C) service D)
zone - ✔✔C) service

✔✔_ valves shall not be located in a room with station outlets or inlets that it controls?
A) main B) service C) source D) zone - ✔✔D) zone

✔✔_ valves shall be readily operable from a standing position in the corridor on the
same floor they serve? A) in-line B) relief C) service D) zone - ✔✔D) zone

✔✔Immediately outside of each vital life-support, critical care, and anesthetizing
location, there shall be a _ valve for each medical gas, vacuum, and WAGD system? A)
fire extinguisher B) local alarm C) relief valve D) zone - ✔✔D) zone

✔✔Operational _ shutoff valves shall be permitted to be installed to isolate or shut off
piping for servicing of individual rooms or areas? A) in-line B) main line C) riser D) zone
- ✔✔A) in-line

✔✔In-line check valves are not required to have _ ? A) brazed extensions B) in-line
serviceability C) threaded end connections D) threaded purge ports - ✔✔C) threaded
end connections

, ✔✔Each station outlet/inlet for medical gasses and vacuums shall be _ ? A) gas-
specific B) interchangeable C) quick-coupler D) threaded - ✔✔A) gas specific

✔✔The factory installed tuning on station outlets and inlets shall extend no further than
_ in. from the body of the terminal? A) 6 B) 8 C) 10 D) 12 - ✔✔B) 8

✔✔Factory installed inlet tubing on station outlets shall not be less than _ NPS? A) 1/4
B) 3/8 C) 1/2 D) 5/8 - ✔✔A) 1/4

✔✔Factory installed outlet tubing on station inlets shall not be less than _ NPS? A) 1/8
B) 3/16 C) 1/4 D) 3/8 - ✔✔D 3/8

✔✔Station outlets that operate at a pressure in excess of _ PSI shall be either D.I.S.S.
or be designed to relieve pressure prior to removal of adapter? A) 50 B) 60 C) 70 D) 80
- ✔✔D) 80

✔✔The manufacturer is allowed a decay of less than _ % in 24 hours during the
standing pressure test? A) 3 B) 2 C) 1.5 D) 1.0 - ✔✔D) 1.0

✔✔The _ shall provide documentation certifying the performance and successful
completion of all pressure testing for a manufactured assembly? A) engineer B) installer
C) manufacturer D) owner - ✔✔C) manufacturer

✔✔Manufactured assemblies employing flexible hose shall have a minimum burst
pressure of _ PSI? A) 1000 B) 1100 C) 1200 D) 1500 - ✔✔A) 1000

✔✔Station outlets and inlets of manufactured assemblies that employ hose or flexible
connections to the piping system are not fully and immediately accessible shall use _
connectors? A) demand check B) D.I.S.S. C) push fit D) quick-coupler - ✔✔B) D.I.S.S.

✔✔The scale range of positive pressure analog indicators shall have the normal
operating pressure fall within the _ of the gauge scale? A) bottom third B) lower third C)
middle third D) top third - ✔✔C) middle third

✔✔The accuracy of digital indicators shall be(+/-) _ % of the operating pressure at
which they are used? A) 20 B) 10 C) 5 D) 1 - ✔✔C) 5

✔✔The scale range of vacuum indicators shall be 0 to _ in. HgV? A) 12 B) 20 C) 30 D)
32 - ✔✔C) 30

✔✔To facilitate service, testing, or replacement, all pressure switches and mainline
gauges downstream of the source valve shall be provided with a _ ? A) check valve B)

Document information

Uploaded on
August 31, 2026
Number of pages
14
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$19.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
EXAMCAFE
3.5
(43)
Sold
297
Followers
11
Items
36820
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions