MEDICAL GAS 6010 COMPREHENSIVE ANSWERS
AND QUESTIONS SET A+
✔✔Joints that have been cleaned onsite shall be brazed within ____ - ✔✔8 hours

✔✔Medical air receivers shall comply with ASME Section ____ - ✔✔8 (VIII)

✔✔Copper inlet tubes on station outlets shall extend no more than ____ - ✔✔8 inches

✔✔Medical surgical vacuum receivers shall comply with ASME Section ____ - ✔✔8

✔✔Central supply systems for nitrous oxide with a total capacity connected and in
storage of 3200lbs or more shall comply with the mandatory requirements of CGA G-
____ Standard for Nitrous Oxide Systems at Consumer Sites - ✔✔8.1

✔✔Micro-bulk & small bulk nitrogen systems shall comply with the mandatory
requirements of CGA P-____ Standard for Bulk Inert Gas Systems at Consumer Sites -
✔✔18

✔✔Central supply systems for bulk inert gases systems with a total capacity connected
and in storage of 20,000ft^3 or more of compressed gas or cryogenic fluid at standard
temperature and pressure, shall comply with the mandatory requirements of CGA ____
- ✔✔

✔✔The minimum backfill cover for the medical gas pipe that is not subject to potential
load is ____ - ✔✔18 inches

✔✔Maintenance personnel shall test flexible connections on booms for leaks every
____ months - ✔✔18

✔✔Station outlets operating more than ____ psi shall not accept an adaptor connector
for an outlet at 50 psi - ✔✔80

, ✔✔Master, area, and local alarms shall include a cancellable audible indicator with a
minimum level of ____ at 3 feet - ✔✔80dBA

✔✔Copper tubing for vacuum systems shall comply with ____ - ✔✔ASTM B88, ASTM
280, or ASTM B819

✔✔Copper tubing for medical gas systems shall comply with ____ Standard
Specifications for Seamless Copper Tubing for Medical Gas Systems - ✔✔ASTM B819

✔✔Type K copper shall be used when operating pressure exceeds a gauge pressure of
____ and the pipe size is larger than 3-1/8 O.D. - ✔✔185 psi

✔✔Liquid oxygen will expand ____ times from its liquid state at room temperature -
✔✔860

✔✔Maximum pipe support spacing for 1-1/4 inch NPS is ____ - ✔✔9 feet

✔✔Welding qualification procedures for medical gas shall be qualified to ASME Section
____ - ✔✔9

✔✔Brazing procedures & brazing performance shall be qualified to ASME Section ____
- ✔✔9

✔✔Ventilation for outdoor and indoor medical gas systems shall comply with Chapter
____ - ✔✔9

✔✔Medical air proportioning systems shall produce medical air with ____% to 23.5% -
✔✔19.5

✔✔Local alarm shall activate when the proportion system content is outside of ____%
to 23.5% - ✔✔19.5

✔✔Medical air filters shall be sized for 100% system peak demand and be rated at
____% efficiency at 1 micron or greater - ✔✔98

✔✔Nonflammable anesthetic agent: Inhalation agent at a vapor pressure of ____
degrees Fahrenheit & an atmospheric pressure cannot attain flammable concentration -
✔✔98.6

✔✔NFPA ____ is the code for the installation of medical gas systems - ✔✔99

Document information

Uploaded on
August 31, 2026
Number of pages
11
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$18.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
EXAMCAFE
3.5
(43)
Sold
297
Followers
11
Items
36820
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions