MASONRY FIELD TESTING TECHNICIAN
CERTIFICATION EXAM PREP NEWEST 2026 | ACI
CERIFIED | ALL MODULES COVERED | PASS
GUARANTEED 2026
Question: The sensor of the temperature measuring device shall be submerged a
minimum of _____ inches into the freshly mixed concrete.

A) 1 inch
B) 2 inches
C) 3 inches
D) 4 inches

Correct Answer: C 3 in. [75 mm]

Expert Rationale: The temperature sensor must be submerged at least 3 inches (75 mm)
into the freshly mixed concrete. Understanding this is essential because proper
submersion ensures the sensor measures the internal temperature of the concrete rather
than surface temperature. This depth provides an accurate representation of the concrete's
thermal condition.



Question: The temperature measuring device must be capable of measuring
temperature within what tolerance?

A) ±2°F [±1°C]
B) ±1°F [±0.5°C]
C) ±0.5°F [±0.25°C]
D) ±3°F [±1.5°C]

Correct Answer: B ±1 degree F [0.5 C]

Expert Rationale: The device must measure temperature within ±1°F (±0.5°C).
Understanding this is essential because accurate temperature measurement is critical for
concrete quality control. Temperature affects setting time, strength development, and
workability of concrete.

,Question: The temperature measuring device must be calibrated _____ or whenever
there is a question of accuracy.

A) Monthly
B) Quarterly
C) Annually
D) Biannually

Correct Answer: C Annually

Expert Rationale: Temperature measuring devices must be calibrated annually or
whenever accuracy is questioned. Understanding this is essential because regular
calibration ensures reliable temperature measurements. Inaccurate readings can lead to
improper concrete placement decisions.



Question: A composite sample of concrete is required even if the only purpose for
obtaining the sample is to determine temperature.

A) True
B) False

Correct Answer: B False

Expert Rationale: A composite sample is not required solely for temperature
determination. Understanding this is essential because temperature can be measured
from a single grab sample when that is the only test being performed. Composite samples
are required when multiple tests (slump, air content, strength) are being conducted.



Question: What must be done to the sample container prior to sampling the concrete?

A) Dry it thoroughly
B) Dampen it with water
C) Heat it
D) Clean it with solvent

Correct Answer: B Dampen (with water)

Expert Rationale: The sample container must be dampened with water prior to sampling.
Understanding this is essential because a dry container can absorb water from the
concrete, altering the water-cement ratio and affecting the concrete's properties.
Dampening prevents this water absorption.

, Question: What must be done to the concrete surrounding the temperature measuring
device after the device is submerged?

A) Tap it with a hammer
B) Gently press the concrete around the device at the surface
C) Cover it with a wet cloth
D) Leave it undisturbed

Correct Answer: B Gently press the concrete around the temperature measuring device at
the surface of the concrete

Expert Rationale: The concrete must be gently pressed around the temperature device at
the surface. Understanding this is essential because this ensures good thermal contact
between the sensor and the concrete, providing an accurate temperature reading. It also
prevents air pockets from insulating the sensor.



Question: How long must the temperature measuring device remain in the freshly
mixed concrete?

A) At least 1 minute but not more than 3 minutes
B) At least 2 minutes but not more than 5 minutes
C) At least 5 minutes but not more than 10 minutes
D) At least 10 minutes

Correct Answer: B At least 2 minutes but not more than 5 minutes

Expert Rationale: The device must remain in the concrete for at least 2 minutes but not
more than 5 minutes. Understanding this is essential because this time allows the sensor
to reach thermal equilibrium with the concrete. Insufficient time yields inaccurate
readings.



Question: After the temperature of the concrete is read, what is required?

A) Recording the temperature
B) Reporting the temperature
C) Discarding the sample
D) Retesting the sample

Correct Answer: B Reporting of temperature

Document information

Uploaded on
August 30, 2026
Number of pages
26
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$10.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
0
Followers
0
Items
81
Last sold
-



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions