Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 12 pages
Exam (elaborations)

GENERAL REQUIREMENTS : SPECIAL INSPECTOR 100% VERIFIED

Document preview thumbnail
Preview 2 out of 12 pages

A special inspector shall demonstrate competence to the satisfaction of the _____________ - ANSWERBuilding Official The special inspector observes critical building or structural elements identified in the statements of special inspections for compliance with __________ and __________ approved by the building official. - ANSWERplans, specifications Who shall the special inspector notify of their presence on a jobsite? - ANSWERContractor Personnel

Content preview

GENERAL REQUIREMENTS : SPECIAL
INSPECTOR 100% VERIFIED
A special inspector shall demonstrate competence to the satisfaction of the
_____________ - ANSWERBuilding Official

The special inspector observes critical building or structural elements identified in the
statements of special inspections for compliance with __________ and __________
approved by the building official. - ANSWERplans, specifications

Who shall the special inspector notify of their presence on a jobsite? -
ANSWERContractor Personnel

All nonconforming items shall be brought to the immediate attention of the -
ANSWERContractor

What are approved plans? - ANSWERPlans that have been approved by governing
jurisdiction.

Who can employ an approved inspection agency? - ANSWEROwner or Owner's agent

Special inspections are in addition to the ______________ performed by the city
inspector and the _____________ performed by the structural engineer of record. -
ANSWERJurisdictional/Municipal Inspections, Structural observation

Special inspections review the _____________ while jurisdictional inspection reviews
the ____________ - ANSWERFine details, Broad details

When nonconforming items are not corrected the special inspector shall notify the
_________ and _________ - ANSWERRegister Design Professional, Building Official

The permit applicant shall submit a statement of special inspections prepared by
the____________ - ANSWERRegistered design professional

Who shall the special inspector furnish inspection reports (progress reports) to? -
ANSWERBuilding official, Registered design professional, and other designated people

Who performs a structural observation? - ANSWERRegistered Design professional.

_____________ is a full time observation of work requiring special inspection -
ANSWERcontinuous special inspection

, Is special inspection required for concrete placement of 3000 psi concrete in isolated
spread footings for a single story warehouse? - ANSWERNo. (isolated spread footings)
IBC 1705.3

Explain what periodic special inspection is - ANSWERSpecial inspection by the special
inspector who is intermittently present where the work to be inspected has been or is
being performed.

Is special inspection required for concrete placement of continuous footings, for poured
in place walls, if the building is two stories in height and engineer included all footings in
his statement of special inspection. - ANSWERYes (IBC 1705.3)

If it takes 6 1/2 hours to pour 4 shear walls and 26 columns on the third level of a ten
story building, how much time is the special inspector required to be on site? -
ANSWERAs long as it takes. (IBC Table 1705.3)

What other tests are required every time strength tests are cast? -
ANSWERTemperature, air content, and slump (IBC Table 1705.3 #6)

Where does it specify the type and extent of special inspections required? -
ANSWERStatement of special instruction (IBC 1704.3.1)

Structural observation is required for all buildings over ______ in height for buildings
located in Seismic Design Category D. - ANSWER75ft (IBC 1704.2 exception 1)

Who can waive the requirement of special inspection on work of a minor nature? -
ANSWERBuilding official

The inspection of curing temperatures and techniques for concrete should be -
ANSWERVerified w/ periodic special inspection (IBC Table 1705.3)

The type and extent of each special inspection shall be located in

a.) Chapter 17 of building code
b.) the statement of special inspection
c.) the job specifications
d.) the approved plans - ANSWERb.) The statement of special inspection


who can issue a stop work order?

a.)registered design professional
b.)building official
c.)contractor
d.)owner - ANSWERb.)building official

Document information

Uploaded on
August 28, 2026
Number of pages
12
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$13.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
shantelleG
4.0
(118)
Sold
651
Followers
369
Items
18358
Last sold
5 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions