Professional Home Inspector Exam NHIE
/ TREC
_____ inches is the maximum distance that a window sill can be positioned from the
ground in a bedroom. - ANS-forty four
_____ inches X ______ inches is the minimal size for a egress window in a
dozing room. - ANS-20 - 24
_____ is the most height of a stairway riser. - ANS-7 ¾"
_______ inspector contributors serve at the Inspector Committee. - ANS-6
_______ participants serve at the Inspector Committee. - ANS-nine
_______ public participants serve at the Inspector Committee. - ANS-3
3 attempts to skip License Exams, then: - ANS-More education is needed
12 gauge aluminum wires need to be linked to a _____ amp breaker. - ANS-15
A _____ inch air gap among a tap spout and the flood rim of its fixture to save you a probable
move connection: - ANS-1
A 2" x 6" @16" on center can appropriately span?
A. 6'
b. 10'
c. 12'
d. Depends on species of wood - ANS-d. Depends on species of wood
A three-tab asphalt shingle can be installed on pitches as low as 2/12, if the roof?
A. Never
b. If the roof has a warm tar roof coating
c. If there are two layers of roofing felt under the shingles
d. Only in case you use a 30 year shingle - ANS-c. If there are layers of roofing felt beneath the
shingles
A constructed-up roof having a lap joint ever 12" is a:
a. Three-ply
,b. 6-ply
c. 2-ply
d. 4-ply roof - ANS-a. 3-ply
A client thinks an inspector turned into negligent, they have to contact _____
to talk about filing a lawsuit. - ANS-An Attorney
A copper-to-steel connection undergoes a/an?
A. Chemical response
b. Electrolytic reaction
c. Nuclear response
d. Thermal response - ANS-b. Electrolytic reaction
A flexible appliance connector can be cut?
A. True
b. False - ANS-b. False
A furnace may be positioned in a laundry room?
A. True
b. False - ANS-a. True
A fused impartial (impartial cord runs to a fuse) is?
A. Ok
b. Unsafe
c. Grand-fathered
d. None of the above - ANS-b. Unsafe
A heat pump machine is frequently sized for the?
A. Cooling load
b. Heating load
c. Need to dehumidify
d. Ambient conditions at some stage in operation - ANS-a. Cooling load
A certified real estate man or woman can also inspect the property in the event that they keep
each licenses. - ANS-False
A method of safety towards backflow shall be provided among the potable water
supply and the irrigation (sprinkler) gadget. Using either atmospheric-type vacuum breakers,
strain-type vacuum breakers or decreased pressure principle backflow preventers. Must be
established at the very least ___ above maximum head. - ANS-6-inches
A minimal of ____ amp rated branch circuits are to be provided to serve
receptacles located within the kitchen, pantry, and breakfast vicinity. - ANS-20
,A non-grounded receptacle inside 6" of water must get replaced with?
A. GFCI
b. GFCI upstream from receptacle
c. Single pole GFCI Breaker
d. All of the above - ANS-d. All of the above
A non-technically exhaustive manner to assess the warmth exchanger?
A. Remove plenum and look into visually
b. Water stress test
c. Check flame sample while blower comes on
d. Inspect sign in covers for soot - ANS-c. Check flame pattern while blower comes on
A fantastic grade faraway from the muse of a home is ____ in ____ . - ANS-6"- 10'
A Real Estate Inspector must have _____ hours of continuing training to resume
his/her license every year. - ANS-sixteen
a bath enclosure that leaks - ANS-Report in need of repair
A popular aircon system can without problems be transformed to a warmness pump by way of
the
addition of a few key additives.
A. True
b. False - ANS-b. False
A stud in a non-load bearing wall can be cut or notched by percent. - ANS-forty
A stud on a load bearing wall can be notched up to _____ percent. - ANS-25
A T&P remedy valve must be designed to perform at what temperature?? - ANS-210 Degrees
A temperature stress remedy valve on a water heater this is hooked up above the tank in
the pipe is incorrect why?
A. Must be mounted inside the top 8-inches of the tank
b. Must be set up in the top 6-inches of the tank
c. Not required to be hooked up within the tank in any respect
d. Not required in older structures - ANS-b. Must be mounted inside the pinnacle 6-inches of the
tank
A vent pipe does now not need to increase past the attic.
A. True
b. False - ANS-b. False
A water heater cannot be located in a Bathroom or bedroom - ANS-True
, A window in a bath calls for safety glazing if the lowest is ___ inches above the bathe pan. -
ANS-Less than 60" in any bathing/swimming place
A wood burning furnace ought to be how a ways away from combustibles - ANS-18"
AC cable, normally referred to as BX, frequently carries a bare aluminum cord. Which of the
following statements is actual concerning the cord?
A. The wire is a grounding cord and must be linked to grounding terminals
inner packing containers and panels.
B. The twine is a bonding cord and should not be connected or brought into the
indoors of containers.
C. The twine is required to be dealt with with anti-oxidant paste at its terminations
d. The twine must be stated as an aluminum branch circuit cord even if the alternative
conductors within the cable are copper - ANS-b. The twine is a bonding cord and have to now
not be connected or added into the
interior of packing containers.
Acceptable Report Changes - ANS-- Font no longer less than 10
- Check Box and Typeface colour
- Delete the "Sponsoring Inspector" area if achieved through a Professional.
- Add a cowl web page
- Add footers to every page apart from the primary
- Add headers to every page
- Add Property Identification and web page numbers on the pinnacle or backside of
each web page.
- Add Subheadings beneath gadgets but you can not renumber or arrange
- Delete the "Other" classes while unused.
According to the policies of the Texas Real Estate Commission, each TREC
licensee shall furnish a permanent address to the fee and all
subsequent changes within __ business days after a trade of
deal with. - ANS-30
According to the Standards of Practice, oven thermostats examined at 350 levels F ought to be
accurate within what range? - ANS-+/- 25 tiers F.
According to the Texas Standards of Practice, the inspector should document the technique
used to inspect the roof, if the inspection is executed from apart from roof level: - ANS-True
According to the TREC SOP, the inspector must document the approach used to look at the
roof, if the inspection is accomplished from apart from a roof stage - ANS-True
All pool, spa, and warm tub lighting over ___ must be GFCI protected. - ANS-15 volts
/ TREC
_____ inches is the maximum distance that a window sill can be positioned from the
ground in a bedroom. - ANS-forty four
_____ inches X ______ inches is the minimal size for a egress window in a
dozing room. - ANS-20 - 24
_____ is the most height of a stairway riser. - ANS-7 ¾"
_______ inspector contributors serve at the Inspector Committee. - ANS-6
_______ participants serve at the Inspector Committee. - ANS-nine
_______ public participants serve at the Inspector Committee. - ANS-3
3 attempts to skip License Exams, then: - ANS-More education is needed
12 gauge aluminum wires need to be linked to a _____ amp breaker. - ANS-15
A _____ inch air gap among a tap spout and the flood rim of its fixture to save you a probable
move connection: - ANS-1
A 2" x 6" @16" on center can appropriately span?
A. 6'
b. 10'
c. 12'
d. Depends on species of wood - ANS-d. Depends on species of wood
A three-tab asphalt shingle can be installed on pitches as low as 2/12, if the roof?
A. Never
b. If the roof has a warm tar roof coating
c. If there are two layers of roofing felt under the shingles
d. Only in case you use a 30 year shingle - ANS-c. If there are layers of roofing felt beneath the
shingles
A constructed-up roof having a lap joint ever 12" is a:
a. Three-ply
,b. 6-ply
c. 2-ply
d. 4-ply roof - ANS-a. 3-ply
A client thinks an inspector turned into negligent, they have to contact _____
to talk about filing a lawsuit. - ANS-An Attorney
A copper-to-steel connection undergoes a/an?
A. Chemical response
b. Electrolytic reaction
c. Nuclear response
d. Thermal response - ANS-b. Electrolytic reaction
A flexible appliance connector can be cut?
A. True
b. False - ANS-b. False
A furnace may be positioned in a laundry room?
A. True
b. False - ANS-a. True
A fused impartial (impartial cord runs to a fuse) is?
A. Ok
b. Unsafe
c. Grand-fathered
d. None of the above - ANS-b. Unsafe
A heat pump machine is frequently sized for the?
A. Cooling load
b. Heating load
c. Need to dehumidify
d. Ambient conditions at some stage in operation - ANS-a. Cooling load
A certified real estate man or woman can also inspect the property in the event that they keep
each licenses. - ANS-False
A method of safety towards backflow shall be provided among the potable water
supply and the irrigation (sprinkler) gadget. Using either atmospheric-type vacuum breakers,
strain-type vacuum breakers or decreased pressure principle backflow preventers. Must be
established at the very least ___ above maximum head. - ANS-6-inches
A minimal of ____ amp rated branch circuits are to be provided to serve
receptacles located within the kitchen, pantry, and breakfast vicinity. - ANS-20
,A non-grounded receptacle inside 6" of water must get replaced with?
A. GFCI
b. GFCI upstream from receptacle
c. Single pole GFCI Breaker
d. All of the above - ANS-d. All of the above
A non-technically exhaustive manner to assess the warmth exchanger?
A. Remove plenum and look into visually
b. Water stress test
c. Check flame sample while blower comes on
d. Inspect sign in covers for soot - ANS-c. Check flame pattern while blower comes on
A fantastic grade faraway from the muse of a home is ____ in ____ . - ANS-6"- 10'
A Real Estate Inspector must have _____ hours of continuing training to resume
his/her license every year. - ANS-sixteen
a bath enclosure that leaks - ANS-Report in need of repair
A popular aircon system can without problems be transformed to a warmness pump by way of
the
addition of a few key additives.
A. True
b. False - ANS-b. False
A stud in a non-load bearing wall can be cut or notched by percent. - ANS-forty
A stud on a load bearing wall can be notched up to _____ percent. - ANS-25
A T&P remedy valve must be designed to perform at what temperature?? - ANS-210 Degrees
A temperature stress remedy valve on a water heater this is hooked up above the tank in
the pipe is incorrect why?
A. Must be mounted inside the top 8-inches of the tank
b. Must be set up in the top 6-inches of the tank
c. Not required to be hooked up within the tank in any respect
d. Not required in older structures - ANS-b. Must be mounted inside the pinnacle 6-inches of the
tank
A vent pipe does now not need to increase past the attic.
A. True
b. False - ANS-b. False
A water heater cannot be located in a Bathroom or bedroom - ANS-True
, A window in a bath calls for safety glazing if the lowest is ___ inches above the bathe pan. -
ANS-Less than 60" in any bathing/swimming place
A wood burning furnace ought to be how a ways away from combustibles - ANS-18"
AC cable, normally referred to as BX, frequently carries a bare aluminum cord. Which of the
following statements is actual concerning the cord?
A. The wire is a grounding cord and must be linked to grounding terminals
inner packing containers and panels.
B. The twine is a bonding cord and should not be connected or brought into the
indoors of containers.
C. The twine is required to be dealt with with anti-oxidant paste at its terminations
d. The twine must be stated as an aluminum branch circuit cord even if the alternative
conductors within the cable are copper - ANS-b. The twine is a bonding cord and have to now
not be connected or added into the
interior of packing containers.
Acceptable Report Changes - ANS-- Font no longer less than 10
- Check Box and Typeface colour
- Delete the "Sponsoring Inspector" area if achieved through a Professional.
- Add a cowl web page
- Add footers to every page apart from the primary
- Add headers to every page
- Add Property Identification and web page numbers on the pinnacle or backside of
each web page.
- Add Subheadings beneath gadgets but you can not renumber or arrange
- Delete the "Other" classes while unused.
According to the policies of the Texas Real Estate Commission, each TREC
licensee shall furnish a permanent address to the fee and all
subsequent changes within __ business days after a trade of
deal with. - ANS-30
According to the Standards of Practice, oven thermostats examined at 350 levels F ought to be
accurate within what range? - ANS-+/- 25 tiers F.
According to the Texas Standards of Practice, the inspector should document the technique
used to inspect the roof, if the inspection is executed from apart from roof level: - ANS-True
According to the TREC SOP, the inspector must document the approach used to look at the
roof, if the inspection is accomplished from apart from a roof stage - ANS-True
All pool, spa, and warm tub lighting over ___ must be GFCI protected. - ANS-15 volts