Fire Protection Systems Chapter 4 Questions with
CORRECT Answers (Grade A+)
Question 1:
A communications system that sends information using Internet protocol technology directly to
individuals or groups no matter their location is known as a(n):
Answer:
distributed recipient mass notification system.
Question 2:
In-building emergency voice/alarm communication systems (EVACS) are an integral part of which
type of building (because this type of building presents rescue challenges for fire personnel)?
Answer:
High-rise building
Question 3:
NFPA 72 provides extensive information concerning fire alarm and detection systems; it is not a(n)
________ specification or approval guide.
Answer:
installation
Question 4:
Some smoke and fire doors are held open by magnets or other devices to allow easy movement from
one part of a building to another, but upon activation of this function, which of the following happens?
Answer:
The device holding the door open releases so the door can close to create a smoke or fire barrier.
Question 5:
The importance of the ________ test cannot be overstated, as a fire alarm system is only as good as its
installation.
Answer:
acceptance
, Question 6:
The person or organization who installed the fire alarm system must provide a _______________ to the
approving authority stating that the system has been installed in accordance with the approved plans
and will function as designed and required.
Answer:
Record of completion
Question 7:
There are a number of building systems that interface with a fire alarm system. Which of the following
prevents propagation of smoke, hot gases, and flame from propagating?
Answer:
The fire dampers close.
Question 8:
Various use and occupant conditions listed in the International Building Code® and NFPA model
codes require the installation of the fire alarm systems to be tied to:
Answer:
the occupancy load. the use-group and occupancy. the level of exit discharge. (all the above).
Question 9:
What does NOT factor into requirements for automatic smoke detection in assembly or business
occupancies?
Answer:
Occupancy load
Question 10:
What is the first factor used to determine any fire alarm installation requirements of a building?
Answer:
Use and occupancy
Question 11:
What system permits first responders and, in some cases, building occupants to communicate between
specific locations within the building and the fire control room via an internal communications system?
Answer:
Two-way emergency communication system
CORRECT Answers (Grade A+)
Question 1:
A communications system that sends information using Internet protocol technology directly to
individuals or groups no matter their location is known as a(n):
Answer:
distributed recipient mass notification system.
Question 2:
In-building emergency voice/alarm communication systems (EVACS) are an integral part of which
type of building (because this type of building presents rescue challenges for fire personnel)?
Answer:
High-rise building
Question 3:
NFPA 72 provides extensive information concerning fire alarm and detection systems; it is not a(n)
________ specification or approval guide.
Answer:
installation
Question 4:
Some smoke and fire doors are held open by magnets or other devices to allow easy movement from
one part of a building to another, but upon activation of this function, which of the following happens?
Answer:
The device holding the door open releases so the door can close to create a smoke or fire barrier.
Question 5:
The importance of the ________ test cannot be overstated, as a fire alarm system is only as good as its
installation.
Answer:
acceptance
, Question 6:
The person or organization who installed the fire alarm system must provide a _______________ to the
approving authority stating that the system has been installed in accordance with the approved plans
and will function as designed and required.
Answer:
Record of completion
Question 7:
There are a number of building systems that interface with a fire alarm system. Which of the following
prevents propagation of smoke, hot gases, and flame from propagating?
Answer:
The fire dampers close.
Question 8:
Various use and occupant conditions listed in the International Building Code® and NFPA model
codes require the installation of the fire alarm systems to be tied to:
Answer:
the occupancy load. the use-group and occupancy. the level of exit discharge. (all the above).
Question 9:
What does NOT factor into requirements for automatic smoke detection in assembly or business
occupancies?
Answer:
Occupancy load
Question 10:
What is the first factor used to determine any fire alarm installation requirements of a building?
Answer:
Use and occupancy
Question 11:
What system permits first responders and, in some cases, building occupants to communicate between
specific locations within the building and the fire control room via an internal communications system?
Answer:
Two-way emergency communication system