1. Min #receptacles in a garage CORRECT ANSWER 1 2. Mobile home service equipment shall be line of sight and no more than from the exterior wall of the home CORRECT ANSWER 30' 3. If a service conductor is over 300V but less than 600V, what is the minimum clearance of that service conductor if it runs in residential and commercial areas that are not subject to traffic? CORRECT ANSWER 15' 4. A power meter must be a minimum of feet away from any door, gas meter, or window opening. CORRECT ANSWER 3 5. A rod-type grounding electrode should have a minimum diameter of CORRECT ANSWER 5/8" 6. Conductors entering buildings shall be protected CORRECT ANSWER To the point of entrance 7. A grounding electrode must be in contact with soil a minimum CORRECT ANSWER 8' 8. If a raceway has various conductors coming from different systems, then you should group each system separately every CORRECT ANSWER 6' 9. What is the maximum distance a service conductor can run over a roof? CORRECT ANSWER 6' 10. Soldered connections are not permitted for CORRECT ANSWER Grounded connections 11. Referto diagram.If you have 0 to 150 nominal voltage to ground, thenwhat is the minimum clear distance required from such equipment? CORRECT ANSWER 3' 12. What color marking isrequired for conductors or busbarsthat carry the highervoltagetogroundandthese markingarerequiredatconnectionpoints that have a grounded conductor present? CORRECT ANSWER Orange 13. What is the purpose of a BOS? CORRECT ANSWER Integrates PV into the building's load 14. Cable trays or similar raceways carrying service entrance conductors must CORRECT ANSWER- CORRECT ANSWER Be Labled 15. Which of the following bulbs cannot be used with dimmer switches? CORRECT ANSWER All of the listed bulb types can be used with dimmers provided the dimmer is designed, tested and UL listed for the specific lighting source or load type. 16. What is the most common location for trim in electrical equipment? CORRECT ANSWER Panelboards 17. What isthe most common locat

Content preview

CALIFORNIA C10 CSLB
ACTUAL EXAM QUESTIONS
AND CORRECT ANSWERS
LATEST UPDATE 2026/2027 .

, 1. Min #receptacles in a garage ✔✔ CORRECT ANSWER 1

2. Mobile home service equipment shall be line of sight and no more than
from the exterior wall of the home ✔✔ CORRECT ANSWER 30'

3. If a service conductor is over 300V but less than 600V, what is the minimum clearance of that service conductor
if it runs in residential and commercial areas that are not subject to traffic? ✔✔ CORRECT ANSWER 15'

4. A power meter must be a minimum of feet away from any door, gas meter, or
window opening. ✔✔ CORRECT ANSWER 3

5. A rod-type grounding electrode should have a minimum diameter of ✔✔ CORRECT ANSWER 5/8"

6. Conductors entering buildings shall be protected ✔✔ CORRECT ANSWER To the point of entrance

7. A grounding electrode must be in contact with soil a minimum ✔✔ CORRECT ANSWER 8'

8. If a raceway has various conductors coming from different systems, then you should group each system
separately every ✔✔ CORRECT ANSWER 6'

9. What is the maximum distance a service conductor can run over a roof? ✔✔ CORRECT ANSWER 6'

10. Soldered connections are not permitted for ✔✔ CORRECT ANSWER Grounded connections

11. Refer to diagram. If you have 0 to 150 nominal voltage to ground, then what is the minimum clear distance
required from such equipment? ✔✔ CORRECT ANSWER 3'

12. What color marking is required for conductors or busbars that carry the higher voltage to ground and these
marking are required at connection points that have a grounded conductor present? ✔✔ CORRECT ANSWER
Orange

13. What is the purpose of a BOS? ✔✔ CORRECT ANSWER Integrates PV into the building's load

14. Cable trays or similar raceways carrying service entrance conductors must ✔✔ CORRECT ANSWER-

✔✔ CORRECT ANSWER Be Labled

15. Which of the following bulbs cannot be used with dimmer switches? ✔✔ CORRECT ANSWER All of the listed bulb
types can be used with dimmers provided the dimmer is designed, tested and UL listed for the specific lighting source or load type.

16. What is the most common location for trim in electrical equipment? ✔✔ CORRECT ANSWER Panel-

boards

17. What is the most common location for terminal lugs? ✔✔ CORRECT ANSWER Batteries in PV system

Document information

Uploaded on
August 25, 2026
Number of pages
5
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$13.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
lectdenis
3.7
(301)
Sold
2089
Followers
1592
Items
6821
Last sold
18 hours ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions