1. During a residential electrical panel inspection, an inspector
observes that the service panel contains a mixture of single-pole and
double-pole breakers. Which observation is MOST important when
determining whether the panel has been properly configured?
A. The double-pole breakers are physically larger than the single-pole
breakers.
B. Each breaker is compatible with the panelboard and properly
connected to the intended circuit conductors.
C. All single-pole breakers are installed on the left side of the panel.
D. The double-pole breakers are located at the bottom of the panel.
Answer: B. Each breaker is compatible with the panelboard and
properly connected to the intended circuit conductors.
Rationale: A residential inspector should verify that overcurrent
devices are listed for use with the specific panelboard, correctly
installed, and appropriately sized for the circuit conductors and
equipment. Physical appearance or location alone does not establish
compliance. Breaker compatibility is particularly important because
breakers that physically fit a panel are not necessarily listed for use
in that panel.*
1
,2. A service panel contains several unused breaker positions. One
opening in the panel dead front is uncovered, allowing access to the
energized interior. What is the primary inspection concern?
A. The panel has too much unused capacity.
B. The panel may have excessive electrical load.
C. The opening compromises the enclosure and permits access to
energized parts.
D. The unused spaces reduce circuit efficiency.
Answer: C. The opening compromises the enclosure and permits
access to energized parts.
Rationale: Unused openings in a panelboard enclosure must be
properly closed using identified filler plates or other approved
means. An open knockout or breaker position can allow accidental
contact with energized components and can compromise the
intended protection provided by the enclosure.*
3. An inspector finds that two branch-circuit conductors are
installed under a single circuit-breaker terminal. What should the
inspector determine before concluding that the installation is
defective?
A. Whether the conductors are copper.
B. Whether the conductors are the same color.
C. Whether the breaker terminal is specifically identified/listed for more
than one conductor.
D. Whether the conductors originate from the same room.
Answer: C. Whether the breaker terminal is specifically
identified/listed for more than one conductor.
Rationale: Multiple conductors under one terminal are not
automatically prohibited in every circumstance. The critical issue is
2
,whether the terminal is identified and listed for the number and
type of conductors installed. If it is not, the conductors require
separate properly rated terminals or another approved
arrangement.*
4. A residential panel contains a circuit breaker rated at 30 amperes
supplying a branch circuit wired with 14 AWG copper conductors.
What is the inspector's primary concern?
A. The breaker is too small for the conductors.
B. The breaker may provide excessive overcurrent protection for the
conductor ampacity.
C. The panel must contain only 20-ampere breakers.
D. The circuit must automatically be converted to a 15-ampere circuit.
Answer: B. The breaker may provide excessive overcurrent
protection for the conductor ampacity.
Rationale: The overcurrent protective device generally must not
exceed the allowable ampacity of the branch-circuit conductors,
subject to specific code provisions and exceptions. A 30-ampere
breaker protecting 14 AWG copper conductors is a significant red
flag because the conductor is ordinarily associated with
substantially lower overcurrent protection. The inspector should
verify conductor size, insulation rating, circuit requirements, and
applicable exceptions before making the final determination.*
5. An inspector identifies a service panel where the grounded circuit
conductors and equipment grounding conductors are terminated on
the same bus. Which factor is most important in evaluating this
arrangement?
3
, A. Whether the panel is painted gray.
B. Whether the panel is located indoors.
C. Whether the panel is the service disconnecting means or a
downstream panel.
D. Whether the conductors are copper or aluminum.
Answer: C. Whether the panel is the service disconnecting means or
a downstream panel.
Rationale: The bonding relationship between grounded conductors
and equipment grounding conductors depends heavily on whether
the enclosure is at the service disconnecting means or is a
downstream distribution panel. At downstream panels, the
grounded conductor is generally isolated from the equipment
grounding/bonding system. Incorrect bonding downstream can
place objectionable current on equipment grounding paths.*
6. During an inspection of a main service panel, the inspector
observes that the grounded conductor bar is bonded to the metal
enclosure. What should the inspector do?
A. Immediately condemn the installation.
B. Determine whether the panel is serving as the service disconnecting
means and whether the bonding connection is properly installed.
C. Remove the bonding screw.
D. Install a second grounding electrode.
Answer: B. Determine whether the panel is serving as the service
disconnecting means and whether the bonding connection is
properly installed.
Rationale: At the service disconnecting means, the grounded
conductor is bonded to the service enclosure and grounding
electrode system as required. The same arrangement is generally
4