1. What is the minimum separation distance
required between a septic tank and a private
water well in Texas?
A. 50 feet
B. 75 feet
C. 100 feet
D. 150 feet
Answer: C
Rationale: According to TCEQ Chapter 285 rules,
a minimum separation distance of 100 feet must
be maintained between any OSSF disposal or
treatment component and a private water well
to prevent contamination.
,2. Which soil class includes coarse sand and
loamy sand that provide the least treatment
efficiency?
A. Class Ia
B. Class Ib
C. Class II
D. Class III
Answer: A
Rationale: Class Ia soils consist of coarse sands
with high hydraulic conductivity, meaning
effluent moves too quickly through them to
receive adequate biological treatment.
3. What is the minimum liquid capacity for a septic
tank serving a single-family dwelling with 3
bedrooms and an estimated flow of less than
300 gallons per day?
A. 750 gallons
B. 1,000 gallons
C. 1,250 gallons
D. 1,500 gallons
Answer: B
Rationale: TCEQ regulations establish that the
minimum permissible septic tank capacity for a
, typical 1 to 3-bedroom residential home is 1,000
gallons.
4. If a septic tank has two compartments, the first
compartment must hold what percentage of the
total structural capacity?
A. 1/3 to 1/2
B. 1/2 to 2/3
C. 2/3 to 3/4
D. Exactly 50%
Answer: B
Rationale: To maximize primary settling and
solids separation, the first compartment of a
multi-compartment septic tank must comprise
two-thirds to three-fourths of the total tank
volume.
5. What type of pipe is required for the solid
gravity sewer line leading from the house to the
septic tank?
A. Schedule 40 PVC
B. Perforated SDR 35
C. Flexible corrugated PE
D. Class 1 Ia sand pipe
Answer: A
Rationale: The tight line from the structure to
, the treatment tank must be a solid, non-
perforated pipe capable of handling structural
loads, typically Schedule 40 PVC or equivalent
structural integrity.
6. What is the maximum acceptable depth for a
standard gravity flow conventional absorption
trench?
A. 12 inches
B. 24 inches
C. 36 inches
D. 48 inches
Answer: C
Rationale: Standard absorption trenches are
restricted to a maximum depth of 36 inches (3
feet) from the natural ground surface to ensure
adequate aerobic activity in the upper soil
profile.
7. Which of the following is considered a
restrictive soil layer that interferes with the
vertical movement of effluent?
A. High organic loam
B. Fractured limestone
C. Dense clay (Class IV)
D. Uniform coarse gravel