Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 4 out of 90 pages
Exam (elaborations)

What is the minimum size of a water meter and service piping in inches for a water supply system of 34 fixture units with a maximum developed length of 200 feet. The water pressure of the system is 35 psi. - CORRECT ANSWER-1 Table AP201.1

Document preview thumbnail
Preview 4 out of 90 pages

What is the minimum size of a water meter and service piping in inches for a water supply system of 34 fixture units with a maximum developed length of 200 feet. The water pressure of the system is 35 psi. - CORRECT ANSWER-1 Table AP201.1

Content preview

IRC Plumbing Practice Test Questions And Answers
2025/2026



What is the minimum size of a water meter and service piping in inches
for a water supply system of 34 fixture units with a maximum
developed length of 200 feet. The water pressure of the system is 35
psi. - CORRECT ANSWER-1


Table AP201.1


What is the minimum sized trap that can be used for the drainage
system of a bathtub (with or without shower head and/or whirlpool
attachments)? - CORRECT ANSWER-1.5


Table P3201.7


A water heater pan drain must extend full-size and terminate over a
suitably located indirect waste receptor or must extend to the exterior
of the building and terminate not less than _____ inches and not more
than _____ inches above the adjacent ground surface. - CORRECT
ANSWER-6, 24

,P2801.6.2


A laundry tray waste line is permitted to connect into a standpipe for
automatic clothes washer drain. The standpipe must extend not less
than _____ above the trap weir and must extend above the flood level
rim of the laundry tray. - CORRECT ANSWER-30 inches (762 mm)


P2706.1.2.1


Clothes closets, linen closets and pantries not exceeding _____ in area,
with the smallest dimension not greater than 3 feet (915 mm) and
having wall and ceiling surfaces of gypsum board will not require fire
sprinklers. - CORRECT ANSWER-24 square feet (2.2 m2)


P2904.1.1


If a water closet can be removed to provide cleanout access, does that
fulfill the cleanout requirement of the code? - CORRECT ANSWER-No


P3005.2.3

,Appliances and equipment used for heating water or storing hot water
have to be protected by _____. - CORRECT ANSWER-pressure-relief
valve and temperature-relief valve or a combination pressure and
temperature-relief valve.


P2804.1


Where the fixture drains connect at different levels, the common vent
must connect as a _____ extension of the _____ drain. - CORRECT
ANSWER-vertical, vertical


P3107.3


The minimum air gap distance in inches for lavatories and other fixtures
with effective opening not greater than 1/2 inch in diameter that are
close to a wall is: - CORRECT ANSWER-1.5


Table P2902.3.1


In areas prone to flooding as established by the code, water supply
systems must be designed and constructed to prevent _____ of
floodwaters. - CORRECT ANSWER-infiltration

, P2602.2


When either a public water-supply or sewer system, or both, are not
available, _____, an individual water-supply or individual sewage-
disposal system, or both, must be provided. - CORRECT ANSWER-or
connection thereto is not feasible


P2602.1


_____ installed in a bathroom are not required to be installed within an
enclosure. - CORRECT ANSWER-direct-vent water heaters


M2005.2


For water supply systems used predominantly for flush tanks having a
water supply fixture unit load of 12, what is the comparable demand in
gallons per minute. - CORRECT ANSWER-16.0


Table P2903.6(1)


Test equipment, materials and labor must be furnished by the ______ -
CORRECT ANSWER-permittee

Document information

Uploaded on
August 19, 2026
Number of pages
90
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$13.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
0
Followers
0
Items
217
Last sold
-



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions