IBHRE CEPS Exam Questions and Answers | Latest Update 2026/2027 | 100% Guaranteed Pass | Graded A+. EKG monitored patient should be __________, monitor chassis should be ___________ (nonconductive). Why - Answer - c ungrounded, grounded. Grounded patient would be able to conduct leakage currents. we dont want this lb to kg - Answer - c 2.2 lb = 1 kg F to C - Answer - c C=5/9(F-32) C to F - Answer - c F=9/5C+32 3 things that change automaticity of automatic cells - Answer - c 1. slope of phase 4 2. Change of threshold potential 3. Change of resting membrane potential a systole is represented by what portion of the ECG - Answer - c QT interval What is main ion transfer during systole - Answer - c K+ seeps out, Ca2+ enters At rest, what is intracellular/extracellular environment - Answer - c inside negative, outside positive What phase of AP is resting membrane potential - Answer - c phase 4 Nodal depolarization occurs via what channel - Answer - c Ca2+ slow channel Cardiac muscle cell depol occurs via what channel - Answer - c Na+ fast channel During which phases is cell refractory - Answer - c 1,2,3 TDP caused by what mechanism usually - Answer - c EAD's (triggered activity) Variance - Answer - c Take each number in sample, subtract each number from mean, square each difference, add all, divide sum by number in sample -1 Standard deviation - Answer - c square root of variance P value - Answer - c Probability of certainty / smaller p value means the more likely the result could not occur by chance survival curve showing % of patients surviving treatment over time - Answer c Kaplan - Meier curves What is 2 rules for CMC's like spiral or lasso - Answer - c 1. Only approved for use in LA due to chordae tendinea 2. Only rotate shaft clockwise Stereotaxis catheters - Answer - c Have magnets in tip for maneuverability in response to changes in magnetic field when measuring EGM's, earliest atrial activation usually from _____ and earliest ventricular usually from ______ - Answer - c P wave / QRS Morady maneuver is used to differentiate - Answer - c differentiate AT from AVNRT/AVRT Most common arrhythmia - Answer - c AF What system remotely steers guided catheters - Answer - c Hansen robotic system ACT for using array - Answer - c ACT 250-300 bipolar cardiac electrodes record local _________ that occur during phase _______ - Answer - c depolarizations / phase 0 surface EKG leads usually filtered at what - Answer - c .1 - 100 Hz Normal EGM filter settings - Answer - c 30 - 300 Hz What to do if T waves interfere with A/V and why - Answer - c Increase the high pass filter because T waves are lower frequency as well as far field Unipolar filter setting - Answer - c .05 - 300 Hz Best needle to use for pericardial space via subxyphoid approach - Answer - c Tuohy needle which type of guide wire is 260-300 cm long? - Answer - c exchange guide wires (much longer than diagnostic catheter) advantage of bipolar leads - Answer - c less prone to EMI noise Unipolar leads more prone to - Answer - c 1. EMI / muscle artifact oversensing 2. pectoralis muscle stimulation (pocket stim) Steroid tip leads reduce acute: - Answer - c inflammation and stimulation threshold Best numbers for ventricular lead - Answer - c How each is measured: Diagnostic catheter OD , Inflated balloon cath OD, Needle OD, Guide wire - Answer - c Diag: Fr / Balloon: mm / Needle: gauge / GW: inch (thousandth of inches) Standard sizes of micropuncture introducer sets and their purpose - Answer - c 21 gauge needle / .018 inch wire. Purpose of micropuncture introducer set is for placement of .035-.038 inch GW Most common SVT - Answer - c AVNRT Thank you for Purchasing this exam Study Guide. We provide high-quality academic materials to help students excel in exams. Our other Services include but not limited to: academic research, University & College assignments writing, essay writing, Online Classes, and research projects. Our services are reliable, affordable, and plagiarism-free. All the Best in your Exam. For more information; Contact us at: or 0R +254

Content preview

IBHRE CEPS Exam Questions and Answers | Latest
Update 2026/2027 | 100% Guaranteed Pass |
Graded A+.



EKG monitored patient should be __________, monitor chassis should be
___________ (nonconductive). Why - Answer - c ungrounded, grounded.
Grounded patient would be able to conduct leakage currents. we dont want this
lb to kg - Answer - c 2.2 lb = 1 kg F to C - Answer - c C=5/9(F-32) C to F -
Answer - c F=9/5C+32
3 things that change automaticity of automatic cells - Answer - c 1.
slope of phase 4
2. Change of threshold
potential
3. Change of resting membrane
potential
a systole is represented by what portion of the ECG - Answer - c QT interval
What is main ion transfer during systole - Answer - c K+ seeps out, Ca2+ enters

At rest, what is intracellular/extracellular environment - Answer - c inside
negative, outside positive

What phase of AP is resting membrane potential - Answer - c phase 4

Nodal depolarization occurs via what channel - Answer - c Ca2+ slow channel

Cardiac muscle cell depol occurs via what channel - Answer - c Na+ fast channel

During which phases is cell refractory - Answer - c 1,2,3

TDP caused by what mechanism usually - Answer - c EAD's (triggered activity)
Variance - Answer - c Take each number in sample, subtract each number from
mean, square each
difference, add all, divide sum by number in
sample -1
Standard deviation - Answer - c square root of variance

,P value - Answer - c Probability of certainty / smaller p value means the more likely
the result could
not occur by
chance
survival curve showing % of patients surviving treatment over time - Answer c
Kaplan - Meier
curves




What is 2 rules for CMC's like spiral or lasso - Answer - c 1. Only approved for
use in LA due to
chordae tendinea

2. Only rotate shaft clockwise

Stereotaxis catheters - Answer - c Have magnets in tip for maneuverability in
response to changes
in magnetic field
when measuring EGM's, earliest atrial activation usually from _____ and earliest
ventricular usually
from ______ - Answer - c P wave
/ QRS
Morady maneuver is used to differentiate - Answer - c differentiate AT from
AVNRT/AVRT

Most common arrhythmia - Answer - c AF


What system remotely steers guided catheters - Answer - c Hansen
robotic system ACT for using array - Answer - c ACT 250-300
bipolar cardiac electrodes record local _________ that occur during phase
_______ - Answer - c

, depolarizations /
phase 0
surface EKG leads usually filtered at what - Answer - c .1 - 100 Hz
Normal EGM filter settings - Answer - c 30 - 300 Hz
What to do if T waves interfere with A/V and why - Answer - c Increase the high
pass filter because
T waves are lower frequency as well as
far field
Unipolar filter setting - Answer - c .05 - 300 Hz




Best needle to use for pericardial space via subxyphoid approach - Answer - c
Tuohy needle
which type of guide wire is 260-300 cm long? - Answer - c exchange guide wires
(much longer than
diagnostic
catheter)
advantage of bipolar leads - Answer - c less prone to EMI noise
Unipolar leads more prone to - Answer - c 1. EMI / muscle artifact
oversensing
2. pectoralis muscle stimulation
(pocket stim)
Steroid tip leads reduce acute: - Answer - c inflammation and stimulation
threshold Best numbers for ventricular lead - Answer - c
How each is measured: Diagnostic catheter OD , Inflated balloon cath OD,
Needle OD, Guide wire -
Answer - c Diag: Fr / Balloon: mm / Needle: gauge / GW: inch
(thousandth of inches)
Standard sizes of micropuncture introducer sets and their purpose - Answer - c
21 gauge needle /
.018 inch wire. Purpose of micropuncture introducer set is for placement of
.035-.038 inch GW




Most common SVT - Answer - c AVNRT

Document information

Uploaded on
August 18, 2026
Number of pages
19
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$15.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
DRBRIGHT2026
3.7
(191)
Sold
964
Followers
697
Items
7068
Last sold
2 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions