1. A traffic signal intersection goes dark during peak traffic hours. What is the
FIRST action a senior technician should take?
A. Replace signal heads immediately
B. Verify power supply and service disconnect status
C. Reprogram controller instantly
D. Shut down cabinet ventilation

Answer: B. Verifying power is the essential first step.




2. A conflict monitor (MMU) enters flash mode repeatedly after rainstorms.
What is the MOST likely cause?
A. Timing optimization
B. Moisture intrusion causing short circuits
C. Excessive cabinet cooling
D. Proper detector operation

Answer: B. Moisture causes intermittent faults that trigger the MMU.




3. What is the primary purpose of a conflict monitor (Malfunction Management
Unit)?
A. Measure traffic volume
B. Detect incompatible signal indications (conflicting greens)
C. Adjust signal timing
D. Control cabinet ventilation

,Answer: B. The MMU detects unsafe conditions and places the intersection into
flash.




4. In a NEMA TS2 cabinet, which component facilitates communication between
the controller and detector racks?
A. Bus Interface Unit (BIU)
B. Malfunction Management Unit (MMU)
C. Input File
D. Conflict Monitor

Answer: C. The Input File houses detector input terminals and facilitates signal
transmission.




5. What is the typical cause of "ghost calls" in inductive loops?
A. Electrical interference or faulty loop
B. Pedestrian button malfunction
C. Signal timing plan error
D. Power outage

Answer: A. Ghost calls occur due to interference or poor loop installation.




6. Which standard governs the placement and design of traffic control devices
in the United States?
A. NEC
B. NESC
C. MUTCD
D. IEEE 802

Answer: C. The Manual on Uniform Traffic Control Devices (MUTCD) is the governing
standard.

,7. A load switch fails in the "stuck on" position. What is the immediate safety
risk?
A. Loss of coordination
B. A signal head may remain lit continuously, potentially causing a conflict
C. The cabinet will overheat
D. The MMU will reset

Answer: B. A stuck load switch can cause a continuous green or red, leading to
conflicts.




8. What is the proper lockout/tagout procedure before entering a cabinet for
maintenance?
A. Turn off the controller only
B. Notify dispatch and remove fuses
C. Isolate, lock, tag, and test all energy sources
D. Wear insulated gloves only

Answer: C. Full LOTO requires isolating, locking, tagging, and testing all sources.




9. Which device converts AC power to DC power for logic circuits in a traffic
cabinet?
A. Load switch
B. Power supply / rectifier
C. Flasher
D. BIU

Answer: B. The power supply or rectifier provides low-voltage DC for logic.




10. A video detection camera loses calibration after heavy snowfall. What is the
BEST corrective action?
A. Replace the camera immediately
B. Clean the lens and re-run calibration zones
C. Increase the gain setting
D. Switch to radar detection permanently

Answer: B. Cleaning and recalibrating is the standard first response.

, 11. What does the term "concurrent phasing" refer to?
A. Two phases that time separately
B. Two or more phases that time together in the same direction
C. A phase that only runs during flash
D. A phase that is skipped

Answer: B. Concurrent phasing allows multiple movements to run simultaneously.




12. A technician measures 240 VAC between L1 and L2 at the service panel.
What is the approximate voltage between L1 and neutral?
A. 480 V
B. 240 V
C. 120 V
D. 208 V

Answer: C. In a standard 120/240V split-phase system, L1 to neutral is 120V.




13. What is the function of a flash transfer relay?
A. To switch the intersection from normal to flash mode
B. To adjust signal timing
C. To power the load switches
D. To communicate with the TMC

Answer: A. The flash transfer relay places the intersection into flash mode when
triggered.




14. Which type of detector is most susceptible to metal reinforcement in
pavement?
A. Radar
B. Video
C. Inductive loop
D. Magnetometer

Document information

Uploaded on
August 18, 2026
Number of pages
88
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$21.29

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
1
Followers
0
Items
318
Last sold
2 weeks ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions