1. Chassis leakage current for electrical equipment in the operating
room must be less than:
A) 10 μA
B) 50 μA
C) 100 μA
D) 500 μA
CORRECT ANSWER: C) 100 μA
Rationale: Chassis leakage refers to current that flows from the
equipment chassis to ground. The maximum allowable chassis
leakage per electrical safety standards (AAMI/NFPA) is less than
100 microamperes (μA) to prevent microshock hazards during
patient monitoring. This is a fundamental safety standard in the
operating room environment.
,2. The maximum leakage current allowed to the patient through
applied electrodes is:
A) 5 μA
B) 10 μA
C) 50 μA
D) 100 μA
CORRECT ANSWER: B) 10 μA
Rationale: Leakage current directed to the patient via monitoring
electrodes must be limited to less than 10 μA to prevent cardiac
microshock. This is critical when electrodes provide a direct
electrical pathway to the heart. The 10 μA limit is a key safety
standard for patient-connected medical equipment.
3. Differential input impedance in a physiological amplifier should
be at least:
A) 1 MΩ
B) 10 MΩ
C) 100 MΩ
D) 1000 MΩ
CORRECT ANSWER: C) 100 MΩ
,Rationale: High input impedance (≥100 MΩ) ensures that the
amplifier does not load the biological signal source, preserving signal
fidelity and minimizing distortion. Most modern IONM amplifiers
meet or exceed this specification. Low input impedance would cause
signal attenuation and degrade the quality of recorded
neurophysiological potentials.
4. Common Mode Rejection Ratio (CMRR) should be at least:
A) 10:1 (20 dB)
B) 100:1 (40 dB)
C) 1,000:1 (60 dB)
D) 10,000:1 (80 dB)
CORRECT ANSWER: D) 10,000:1 (80 dB)
Rationale: A CMRR of 80 dB (10,000:1) ensures that common-mode
signals (e.g., 60 Hz interference) are adequately rejected, preserving
the differential biological signal of interest. This high rejection ratio
is essential in the electrically noisy OR environment to obtain clean
neurophysiologic recordings.
5. The minimum recommended bandpass for IONM amplifiers is:
A) 0.1–100 Hz
, B) 1–1,000 Hz
C) 0.1–15,000 Hz
D) 10–10,000 Hz
CORRECT ANSWER: C) 0.1–15,000 Hz
Rationale: This wide bandpass (0.1–15,000 Hz) accommodates both
slow cortical potentials and fast nerve action potentials. The low-
frequency setting (0.1 Hz) preserves slow wave components while
the high-frequency setting (15,000 Hz) captures fast signal
components essential for accurate waveform representation.
6. Horizontal resolution in digital neurophysiologic recording
systems should be:
A) <50 μs/data point
B) <20 μs/data point (sampling rate >50,000)
C) <100 μs/data point
D) <10 μs/data point
CORRECT ANSWER: B) <20 μs/data point (sampling rate
>50,000)
Rationale: Horizontal resolution refers to the sampling interval. A
sampling rate greater than 50,000 samples per second (providing <20