Content preview

Which of the following values is the best indicator of an individual's response to
inhaled bronchodilators?



A.FVC
B.FEV1
C.FEF200-1200
D.diffusing capacity


Give this one a try later!


B.√FEV1
(c) B. FEV1 is the best indicator of reversible airway obstruction in response
to inhaled bronchodilators.




A patient receiving oxygen at 2 L/min through a transtracheal catheter complains that
the supply tubing keeps popping off of the catheter. To correct this problem, a

,respiratory therapist should


A.decrease the flow of oxygen.
B.check the catheter for obstruction.
C.perform endotracheal suctioning.
D.tape the connection securely.


Give this one a try later!


B.√check the catheter for obstruction.

(c) B. The description suggests obstruction of the catheter due to kinking or
mucous, resulting in significant back pressure causing the supply tube to
pop off.




A respiratory therapist is reviewing the medical record of an infant to determine
whether any respiratory care is indicated in the home. Which of the following suggests
the need for home apnea monitoring?



A.albuterol aerosol every 4 hours prn
B.√caffeine citrate daily
C.APGAR scores of 3 and 4
D.oxygen by cannula at 0.25 L/min


Give this one a try later!


B.√caffeine citrate daily
(c) B. Caffeine citrate is used to treat apneic conditions and indicates the
need for home apnea monitoring.




A DLCO measuring device requires evaluation after being taken out of service
because of erroneous values. Which of the following is critical to evaluate?

,A.linearity of pressure drops
B.verification of shutter response
C.verification of He percentage
D.linearity of analyzed gas concentrations


Give this one a try later!


D.√linearity of analyzed gas concentrations


(c) D. The integrity of the gas analysis system and its ability to return
expected results are critical elements in DLCO measurement.




A respiratory therapist is called to the bedside of an adult patient in respiratory
distress. The patient is receiving VC, A/C ventilation and the following volume-
pressure loop is observed: football image in mid falling down


The therapist should conclude


A.the system has a leak.
B.the airway is obstructed.
C.the tidal volume is too high.
D.secretions are present.


Give this one a try later!


A.√the system has a leak.



(c) A. The graphic shows that the volume isn't returning to baseline and a
leak is present.

, When measuring vital capacity, a respiratory therapist should instruct a patient to
inhale


A.maximally and exhale to FRC.
B.maximally and exhale maximally.
C.normally and exhale to FRC.
D.normally and exhale maximally.


Give this one a try later!


B.√maximally and exhale maximally.

(c) B. Vital capacity is performed by having the patient inhale to total lung
capacity and maximally exhale to residual volume.




When extubating an adult patient, which of the following should a respiratory
therapist do FIRST?
A.Deflate the cuff.
B.Remove the tube holder from the patient's face.
C.Position the patient in an upright position.
D.Suction while the patient coughs.


Give this one a try later!


C.√Position the patient in an upright position.

(c) C. The patient should first be placed in high Fowler's position.




A patient with COPD is receiving PC ventilation with flow triggering and has
significant air trapping displayed on ventilator graphics. The patient's spontaneous
breathing efforts are not always detected by the ventilator. Which of the following

Document information

Uploaded on
August 12, 2026
Number of pages
36
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$10.50

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TestITandFixIT
3.4
(10)
Sold
54
Followers
0
Items
6989
Last sold
2 weeks ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions