EPA 608 CERTIFICATION EXAM 2026/2027 COMPLETE QUESTIONS WITH 100% VERIFIED ANSWERS

Document preview thumbnail
Preview 4 out of 81 pages

EPA 608 CERTIFICATION EXAM 2026/2027 COMPLETE QUESTIONS WITH 100% VERIFIED ANSWERS 1. What date was the sale of CFCs and HCFCs restricted to technicians certified in refrigerant recovery? A) November 14, 1994 B) July 1, 1992 C) November 15, 1993 D) December 31, 1995 Correct Answer: A) November 14, 1994 Rationale: The sale of CFC and HCFC refrigerants was restricted to certified technicians beginning November 14, 1994, the same date technician certification became required for servicing appliances. ________________________________________ 2. The Montreal Protocol was established in which year? A) 1987 B) 1989 C) 1990 D) 1992 Correct Answer: B) 1989 Rationale: The Montreal Protocol was established in 1989 and served as the international treaty basis for Section 608 of the Clean Air Act. ________________________________________ 3. On what date did it become a violation to vent CFCs or HCFCs? A) November 15, 1993 B) July 1, 1992 C) November 14, 1994 D) November 15, 1995 Correct Answer: B) July 1, 1992 Rationale: July 1, 1992 marked the date when venting CFCs or HCFCs became a violation under EPA regulations. ________________________________________ 4. Recovery and recycling equipment must be certified and labeled by the EPA as of what date? A) November 14, 1994 B) July 1, 1992 C) November 15, 1993 D) December 31, 1995 Correct Answer: C) November 15, 1993 Rationale: On November 15, 1993, recovery and recycling equipment was required to be certified and labeled by the EPA, and higher evacuation levels were required. ________________________________________ 5. Before November 15, 1993, recovery equipment needed to be capable of removing what percentage of refrigerant? A) 90% B) 80% C) 95% D) 75% Correct Answer: B) 80% Rationale: Before November 15, 1993, recovery equipment needed to be capable of removing 80% of the refrigerant, with or without a working compressor, or achieve 4 inches Hg vacuum. ________________________________________ 6. After November 15, 1993, recovery equipment must be capable of removing what percentage of refrigerant? A) 80% B) 85% C) 90% D) 95% Correct Answer: C) 90% Rationale: After November 15, 1993, recovery equipment needs to be capable of removing 90% of the refrigerant, or 80% without a working compressor, or 4 inches Hg vacuum. ________________________________________ 7. What was the required level of evacuation for low-pressure appliances before November 15, 1993? A) 25 mm Hg B) 25 inches Hg C) 10 inches Hg D) 4 inches Hg Correct Answer: B) 25 inches Hg Rationale: Before November 15, 1993, the required evacuation level for low-pressure appliances was 25 inches Hg. ________________________________________ 8. What was the required level of evacuation for low-pressure appliances after November 15, 1993? A) 25 mm Hg B) 25 inches Hg C) 10 mm Hg D) 4 inches Hg Correct Answer: A) 25 mm Hg Rationale: After November 15, 1993, the required evacuation level for low-pressure appliances became 25 mm Hg (which is a deeper vacuum than 25 inches Hg). ________________________________________ 9. On what date did it become a violation to vent HFCs? A) November 15, 1993 B) July 1, 1992 C) November 14, 1994 D) November 15, 1995 Correct Answer: D) November 15, 1995 Rationale: November 15, 1995 marked the date when venting HFCs became a violation under EPA regulations. ________________________________________

Content preview

EPA 608 CERTIFICATION EXAM 2026/2027 COMPLETE
QUESTIONS WITH 100% VERIFIED ANSWERS



1. What date was the sale of CFCs and HCFCs restricted to technicians
certified in refrigerant recovery?
A) November 14, 1994
B) July 1, 1992
C) November 15, 1993
D) December 31, 1995
Correct Answer: A) November 14, 1994
Rationale: The sale of CFC and HCFC refrigerants was restricted to
certified technicians beginning November 14, 1994, the same date
technician certification became required for servicing appliances.


2. The Montreal Protocol was established in which year?
A) 1987
B) 1989
C) 1990
D) 1992
Correct Answer: B) 1989
Rationale: The Montreal Protocol was established in 1989 and served as
the international treaty basis for Section 608 of the Clean Air Act.

,3. On what date did it become a violation to vent CFCs or HCFCs?
A) November 15, 1993
B) July 1, 1992
C) November 14, 1994
D) November 15, 1995
Correct Answer: B) July 1, 1992
Rationale: July 1, 1992 marked the date when venting CFCs or HCFCs
became a violation under EPA regulations.


4. Recovery and recycling equipment must be certified and labeled by
the EPA as of what date?
A) November 14, 1994
B) July 1, 1992
C) November 15, 1993
D) December 31, 1995
Correct Answer: C) November 15, 1993
Rationale: On November 15, 1993, recovery and recycling equipment
was required to be certified and labeled by the EPA, and higher
evacuation levels were required.


5. Before November 15, 1993, recovery equipment needed to be
capable of removing what percentage of refrigerant?
A) 90%
B) 80%

,C) 95%
D) 75%
Correct Answer: B) 80%
Rationale: Before November 15, 1993, recovery equipment needed to
be capable of removing 80% of the refrigerant, with or without a
working compressor, or achieve 4 inches Hg vacuum.


6. After November 15, 1993, recovery equipment must be capable of
removing what percentage of refrigerant?
A) 80%
B) 85%
C) 90%
D) 95%
Correct Answer: C) 90%
Rationale: After November 15, 1993, recovery equipment needs to be
capable of removing 90% of the refrigerant, or 80% without a working
compressor, or 4 inches Hg vacuum.


7. What was the required level of evacuation for low-pressure
appliances before November 15, 1993?
A) 25 mm Hg
B) 25 inches Hg
C) 10 inches Hg
D) 4 inches Hg

, Correct Answer: B) 25 inches Hg
Rationale: Before November 15, 1993, the required evacuation level for
low-pressure appliances was 25 inches Hg.


8. What was the required level of evacuation for low-pressure
appliances after November 15, 1993?
A) 25 mm Hg
B) 25 inches Hg
C) 10 mm Hg
D) 4 inches Hg
Correct Answer: A) 25 mm Hg
Rationale: After November 15, 1993, the required evacuation level for
low-pressure appliances became 25 mm Hg (which is a deeper vacuum
than 25 inches Hg).


9. On what date did it become a violation to vent HFCs?
A) November 15, 1993
B) July 1, 1992
C) November 14, 1994
D) November 15, 1995
Correct Answer: D) November 15, 1995
Rationale: November 15, 1995 marked the date when venting HFCs
became a violation under EPA regulations.

Document information

Uploaded on
August 11, 2026
Number of pages
81
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$16.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
maingirose
5.0
(3)
Sold
23
Followers
0
Items
1676
Last sold
4 hours ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions