Advanced Practice Exam 2026 | 100
Questions & Answers with Detailed
Rationales | Complete Exam Prep &
Study Guide
1. Under Georgia's elevator regulations, which certification class generally
authorizes a mechanic to install, service, repair, test, maintain, and perform
electrical work on elevators and related conveyance equipment?
A. Class II
B. Class III
C. Class I
D. Inspector certification
Answer: Class I
Rationale: Class I elevator mechanic certification authorizes installation,
servicing, repair, testing, maintenance, and electrical work on elevators and
related conveyance equipment covered by the Georgia rules.
2. A Class II elevator mechanic is performing maintenance on equipment outside
the scope of the contractor for whom the mechanic works. What is the primary
concern?
,A. The mechanic may perform any elevator work independently
B. Class II certification automatically authorizes installation
C. The mechanic must remain within the certification and employment
limitations applicable to Class II work
D. Only the building owner determines the mechanic's permitted scope
Answer: The mechanic must remain within the certification and employment
limitations applicable to Class II work
Rationale: Georgia defines Class II mechanics more narrowly than Class I
mechanics. Class II mechanics are authorized to service, repair, test, and
maintain covered conveyance equipment and must be employed by a Class II
elevator contractor or owner-user.
3. Which standard is the principal safety code adopted by Georgia for elevators,
escalators, dumbwaiters, and moving walks?
A. NFPA 13
B. NFPA 70 only
C. ICC A117.1 only
D. ASME A17.1
Answer: ASME A17.1
Rationale: Georgia's elevator rules adopt ASME A17.1, currently identified in the
regulations as the 2019 edition, subject to Georgia's specified amendments and
exceptions.
4. Which ASME publication is specifically identified by Georgia as the Inspector's
Manual for Elevators?
A. A17.1
B. A17.3
C. A17.2
D. A18.1
Answer: ASME A17.2
,Rationale: Georgia identifies ASME A17.2 as the Inspector's Manual for
Elevators and requires certified inspectors to use the latest adopted edition as
specified by the state rules.
5. What is the principal purpose of the Georgia elevator regulations?
A. Establish maximum elevator speeds for every building
B. Establish only electrical installation requirements
C. Establish minimum safety standards intended to prevent loss of life, injury,
and structural damage
D. Regulate only elevator manufacturers
Answer: Establish minimum safety standards intended to prevent loss of life,
injury, and structural damage
Rationale: The Georgia rules state that their purpose is to establish minimum
fire-safety codes and standards for elevators and escalators and promote public
safety and consumer protection.
6. A mechanic discovers that a critical safety device has been intentionally
bypassed. What should be the mechanic's first priority?
A. Complete the scheduled maintenance and report it later
B. Reset the device and continue normal operation
C. Place the equipment in a safe condition and correct or report the unsafe
condition before returning it to service
D. Remove the device permanently
Answer: Place the equipment in a safe condition and correct or report the
unsafe condition before returning it to service
Rationale: Safety circuits and protective devices are fundamental to elevator
operation. A bypassed safety device can defeat the protective sequence and
create an unacceptable hazard.
7. What is the primary purpose of an elevator governor?
, A. Control cab lighting
B. Maintain hydraulic pressure
C. Control door-open time
D. Detect excessive car speed and initiate the appropriate safety response
Answer: Detect excessive car speed and initiate the appropriate safety response
Rationale: The governor is part of the elevator overspeed protection system.
When the governor reaches its applicable tripping condition, it initiates actions
that can cause the car safety system to engage.
8. A mechanic is troubleshooting an intermittent door-lock fault. Which
approach is most appropriate?
A. Permanently jumper the door-lock circuit
B. Replace the controller immediately without testing
C. Verify the electrical circuit systematically, including door contacts, wiring,
terminals, and controller inputs
D. Increase the door-closing force until the fault disappears
Answer: Verify the electrical circuit systematically, including door contacts,
wiring, terminals, and controller inputs
Rationale: Intermittent faults require systematic troubleshooting. Jumping a
safety or door-lock circuit can defeat protective functions and create a serious
hazard.
9. What is the primary function of the door interlock?
A. Increase motor torque
B. Control leveling speed
C. Prevent the elevator from operating unless the hoistway door is properly
secured
D. Control car lighting
Answer: Prevent the elevator from operating unless the hoistway door is
properly secured