Workspace in front of an electrical panel board shall be a minimum of __" width, but no less
than the width of the panel board. ✔Correct Answer-30"

The minimum size conductor for feeders and branch circuits shall be __ copper. ✔Correct
Answer-14 Gauge

What is the minimum permitted size of a grounded service conductor serving a maximum of
150 amps? ✔Correct Answer-1/0 Copper (?)

What is the maximum over current protection device rating for No. 12 copper conductors?
✔Correct Answer-20 amps

Receptacle outlets shall be installed so that all points along the floor line in any wall space are a
maximum of __ feet from an outlet in that space when measure horizontally. ✔Correct
Answer-6 feet

Where installed in a storage closet, a recessed fluorescent luminaire shall be located so as to
provide a minimum clearance of __" between the fixture and the nearest point of the storage
space. ✔Correct Answer-6"

Where installed in a storage closet, a covered incandescent light shall be located so as to
provide a minimum clearance of __" between the fixture and the nearest point of the storage
space. ✔Correct Answer-12"

Hanging luminaires lighting track and pendants shall be located a minimum of _____
horizontally and _____ vertically from the top of a bathtub rim or shower stall threshold
✔Correct Answer-3' horizontally / 8' vertically

What is the component that introduces cold water near the bottom of a gas-fired water heater?
✔Correct Answer-The Dip Tube

What is the typical maximum distance between the fixture and the trap? ✔Correct Answer-
24" vertical / 30" horizontal

Where copper piping is to pass through holes bored in wood study, the pipe shall be protected
by shield plates except for those holes that are a minimum of __ from the nearest edge.
✔Correct Answer-1-1/2"

, A fixture tailpiece for a laundry tub shall be a minimum of __" diameter. ✔Correct Answer-1-
1/2"

What is the maximum number of fixtures connected to a horizontal branch drain that are
permitted to be circuit vented? ✔Correct Answer-8

The fixture drain length between the trap weir and the vent connection fitting should be __.
✔Correct Answer-At least two (2) pipe diameters

An open vent terminal extending through an exterior wall shall terminate a minimum of ___'
from the lot line. ✔Correct Answer-10'

Water heater T&P valve should be set so that the maximum temperature reached is ?
✔Correct Answer-210 DegF

A water heater pressure relief valve shall be set to open at ___ PSI ✔Correct Answer-150 psi

For other than black steel pipe, exposed gas piping shall be identified by a yellow label spaced a
maximum interval of ___ ✔Correct Answer-5 feet

In which of the following locations is the installation of gas piping not specifically prohibited?
a) In a circulating air duct
b) Through a clothes chute
c) Appliance vents
d) Adjacent to an exterior stairway ✔Correct Answer-d) Adjacent to an exterior stairway

For gas piping other than black or galvanized steel installed in a concealed location, a shield
plate shall be provided for protection against physical damage where a bored hole is located a
maximum of ___ from the edge of the wood member. ✔Correct Answer-1-1/4"

What is the maximum operating pressure for Polyvinyl chloride water pipe? ✔Correct
Answer-80 psi

Which statement would be true about steam heating systems?
a) The are insufficient
b) They require regular occupant maintenance
c) They make a lot of noise
d) They need a walkway ✔Correct Answer-b) They require regular occupant maintenance

Which statement about heat is false?
a) It's the amount of thermal energy in a body
b) It's measure in Deg. Fahrenheit
c) Sensible heat is one type

Document information

Uploaded on
August 9, 2026
Number of pages
5
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$13.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Stuvia2026
2.3
(3)
Sold
26
Followers
1
Items
6412
Last sold
3 weeks ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions